메뉴 건너뛰기




Volumn 109, Issue 2, 2011, Pages 178-185

Unfolded partial least-squares with residual quadrilinearization: A new multivariate algorithm for processing five-way data achieving the second-order advantage. Application to fourth-order excitation-emission-kinetic-pH fluorescence analytical data

Author keywords

Five way data; Fluorescent analysis; Partial least squares; Residual quadrilinearization

Indexed keywords

CARBARIL; FUBERIDAZOLE; TIABENDAZOLE;

EID: 80055096898     PISSN: 01697439     EISSN: 18733239     Source Type: Journal    
DOI: 10.1016/j.chemolab.2011.09.002     Document Type: Article
Times cited : (48)

References (44)
  • 1
    • 33845429108 scopus 로고    scopus 로고
    • Review on multiway analysis in chemistry - 2000-2005
    • Bro R. Review on multiway analysis in chemistry - 2000-2005. Critical Reviews in Analytical Chemistry 2006, 36:279-293.
    • (2006) Critical Reviews in Analytical Chemistry , vol.36 , pp. 279-293
    • Bro, R.1
  • 3
    • 79952900257 scopus 로고    scopus 로고
    • Second-order and higher-order multivariate calibration methods applied to non-multilinear data using different algorithms
    • Olivieri A.C., Escandar G.M., Muñoz de la Peña A. Second-order and higher-order multivariate calibration methods applied to non-multilinear data using different algorithms. Trends in Analytical Chemistry 2011, 30:607-617.
    • (2011) Trends in Analytical Chemistry , vol.30 , pp. 607-617
    • Olivieri, A.C.1    Escandar, G.M.2    Muñoz de la Peña, A.3
  • 5
    • 0017995905 scopus 로고
    • Application of the method of rank annihilation to quantitative analyses of multicomponent fluorescence data from the video fluorometer
    • Ho C.N., Christian G.D., Davidson E.R. Application of the method of rank annihilation to quantitative analyses of multicomponent fluorescence data from the video fluorometer. Analytical Chemistry 1978, 50:1108-1113.
    • (1978) Analytical Chemistry , vol.50 , pp. 1108-1113
    • Ho, C.N.1    Christian, G.D.2    Davidson, E.R.3
  • 6
    • 49449099440 scopus 로고    scopus 로고
    • Analytical advantages of multivariate data processing. One, two, three, infinity?
    • Olivieri A.C. Analytical advantages of multivariate data processing. One, two, three, infinity?. Analytical Chemistry 2008, 80:5713-5720.
    • (2008) Analytical Chemistry , vol.80 , pp. 5713-5720
    • Olivieri, A.C.1
  • 7
    • 1042297610 scopus 로고    scopus 로고
    • Theory of net analyte signal vectors in inverse regression
    • Andersen C.M., Bro R. Theory of net analyte signal vectors in inverse regression. Journal of Chemometrics 2003, 17:200-215.
    • (2003) Journal of Chemometrics , vol.17 , pp. 200-215
    • Andersen, C.M.1    Bro, R.2
  • 8
    • 4744337717 scopus 로고    scopus 로고
    • Second-order advantage achieved with four-way fluorescence excitation-emission-kinetic data processed by parallel factor analysis and trilinear least-squares. determination of methotrexate and leucovorin in human urine
    • Olivieri A.C., Arancibia J.A., Muñoz de la Peña A., Durán Merás I., Espinosa Mansilla A. Second-order advantage achieved with four-way fluorescence excitation-emission-kinetic data processed by parallel factor analysis and trilinear least-squares. determination of methotrexate and leucovorin in human urine. Analytical Chemistry 2004, 76:5657-5666.
    • (2004) Analytical Chemistry , vol.76 , pp. 5657-5666
    • Olivieri, A.C.1    Arancibia, J.A.2    Muñoz de la Peña, A.3    Durán Merás, I.4    Espinosa Mansilla, A.5
  • 10
    • 34248324815 scopus 로고    scopus 로고
    • Evaluation of unfolded-partial least-squares coupled to residual trilinearization for four-way calibration of folic acid and methotrexate in human serum samples
    • Muñoz de la Peña A., Durán Merás I., Jiménez Girón A., Goicoechea H.C. Evaluation of unfolded-partial least-squares coupled to residual trilinearization for four-way calibration of folic acid and methotrexate in human serum samples. Talanta 2007, 72:1261-1267.
    • (2007) Talanta , vol.72 , pp. 1261-1267
    • Muñoz de la Peña, A.1    Durán Merás, I.2    Jiménez Girón, A.3    Goicoechea, H.C.4
  • 11
    • 46049106321 scopus 로고    scopus 로고
    • On line photochemically induced excitation-emission-kinetic four-way data. Analytical application for the determination of folic acid and its two main metabolites in serum by U-PLS and N-PLS/residual trilinearization (RTL) calibration
    • Jiménez Girón A., Durán Merás I., Espinosa Mansilla A., Muñoz de la Peña A., Cañada Cañada F., Olivieri A.C. On line photochemically induced excitation-emission-kinetic four-way data. Analytical application for the determination of folic acid and its two main metabolites in serum by U-PLS and N-PLS/residual trilinearization (RTL) calibration. Analytica Chimica Acta 2008, 622:94-103.
    • (2008) Analytica Chimica Acta , vol.622 , pp. 94-103
    • Jiménez Girón, A.1    Durán Merás, I.2    Espinosa Mansilla, A.3    Muñoz de la Peña, A.4    Cañada Cañada, F.5    Olivieri, A.C.6
  • 12
    • 34548783830 scopus 로고    scopus 로고
    • Multiway partial least-squares coupled to residual trilinearization: a genuine multidimensional tool for the study of third-order data. Simultaneous analysis of procaine and its metabolite p-aminobenzoic acid in equine serum
    • Damiani P.C., Durán Merás I., García Reiriz A.G., Jiménez Girón A., Muñoz de la Peña A., Olivieri A.C. Multiway partial least-squares coupled to residual trilinearization: a genuine multidimensional tool for the study of third-order data. Simultaneous analysis of procaine and its metabolite p-aminobenzoic acid in equine serum. Analytical Chemistry 2007, 76:6949-6958.
    • (2007) Analytical Chemistry , vol.76 , pp. 6949-6958
    • Damiani, P.C.1    Durán Merás, I.2    García Reiriz, A.G.3    Jiménez Girón, A.4    Muñoz de la Peña, A.5    Olivieri, A.C.6
  • 13
    • 10044249034 scopus 로고    scopus 로고
    • Multivariate curve resolution applied to the analysis and resolution of two-dimensional [1H,15N] NMR reaction spectra
    • Jaumot J., Marchán V., Gargallo R., Grandas A., Tauler R. Multivariate curve resolution applied to the analysis and resolution of two-dimensional [1H,15N] NMR reaction spectra. Analytical Chemistry 2004, 76:7094-7101.
    • (2004) Analytical Chemistry , vol.76 , pp. 7094-7101
    • Jaumot, J.1    Marchán, V.2    Gargallo, R.3    Grandas, A.4    Tauler, R.5
  • 14
  • 15
    • 0002070552 scopus 로고
    • Resolution of multicomponent fluorescent mixtures by analysis of the excitation-emission-frequency array
    • Burdick D.S., Tu X.M., McGown L.B., Millican D.W. Resolution of multicomponent fluorescent mixtures by analysis of the excitation-emission-frequency array. Journal of Chemometrics 1990, 4:15-28.
    • (1990) Journal of Chemometrics , vol.4 , pp. 15-28
    • Burdick, D.S.1    Tu, X.M.2    McGown, L.B.3    Millican, D.W.4
  • 16
    • 17644423181 scopus 로고    scopus 로고
    • Four-way data coupled to parallel factor model applied to environmental analysis: determination of 2,3,7,8-tetrachloro-dibenzo-para-dioxin in highly contaminated waters by solid-liquid extraction laser-excited time-resolved Spol'skii spectroscopy
    • Goicoechea H.C., Yu S., Olivieri A.C., Campiglia A.D. Four-way data coupled to parallel factor model applied to environmental analysis: determination of 2,3,7,8-tetrachloro-dibenzo-para-dioxin in highly contaminated waters by solid-liquid extraction laser-excited time-resolved Spol'skii spectroscopy. Analytical Chemistry 2005, 77:2608-2616.
    • (2005) Analytical Chemistry , vol.77 , pp. 2608-2616
    • Goicoechea, H.C.1    Yu, S.2    Olivieri, A.C.3    Campiglia, A.D.4
  • 17
    • 0034621523 scopus 로고    scopus 로고
    • Resolution of kinetic system of simultaneous degradations of chlorophyll a and b by PARAFAC
    • Tan Y., Jiang J.H., Wu H.L., Cui H., Yu R.Q. Resolution of kinetic system of simultaneous degradations of chlorophyll a and b by PARAFAC. Analytica Chimica Acta 2000, 412:195-202.
    • (2000) Analytica Chimica Acta , vol.412 , pp. 195-202
    • Tan, Y.1    Jiang, J.H.2    Wu, H.L.3    Cui, H.4    Yu, R.Q.5
  • 19
    • 33746266278 scopus 로고    scopus 로고
    • Four-way calibration applied to the simultaneous determination of folic acid and methotrexate in urine samples
    • Muñoz de la Peña A., Durán Merás I., Jiménez Girón A. Four-way calibration applied to the simultaneous determination of folic acid and methotrexate in urine samples. Analytical and Bioanalytical Chemistry 2006, 385:1289-1297.
    • (2006) Analytical and Bioanalytical Chemistry , vol.385 , pp. 1289-1297
    • Muñoz de la Peña, A.1    Durán Merás, I.2    Jiménez Girón, A.3
  • 20
    • 34548785510 scopus 로고    scopus 로고
    • Alternating penalty quadrilinear decomposition algorithm for an analysis of four-way data arrays
    • Xia A.L., Wu H.L., Li S.F., Zhu S.H., Hu L.Q., Yu R.Q. Alternating penalty quadrilinear decomposition algorithm for an analysis of four-way data arrays. Journal of Chemometrics 2007, 21:133-144.
    • (2007) Journal of Chemometrics , vol.21 , pp. 133-144
    • Xia, A.L.1    Wu, H.L.2    Li, S.F.3    Zhu, S.H.4    Hu, L.Q.5    Yu, R.Q.6
  • 21
    • 58149503963 scopus 로고    scopus 로고
    • Excitation-emission-kinetic fluorescence coupled with third-order calibration for quantifying carbaryl and investigating the hydrolysis in effluent water
    • Zhu S.H., Wu H.L., Xia A.L., Nie J.F., Bian Y.C., Cai C.B., Yu R.Q. Excitation-emission-kinetic fluorescence coupled with third-order calibration for quantifying carbaryl and investigating the hydrolysis in effluent water. Talanta 2009, 77:1640-1646.
    • (2009) Talanta , vol.77 , pp. 1640-1646
    • Zhu, S.H.1    Wu, H.L.2    Xia, A.L.3    Nie, J.F.4    Bian, Y.C.5    Cai, C.B.6    Yu, R.Q.7
  • 22
    • 77956611605 scopus 로고    scopus 로고
    • Four-way kinetic-excitation-emission fluorescence data processed by multi-way algorithms. Determination of carbaryl and 1-naphthol in water samples in the presence of fluorescent interferents
    • Maggio R.M., Damiani P.C., Olivieri A.C. Four-way kinetic-excitation-emission fluorescence data processed by multi-way algorithms. Determination of carbaryl and 1-naphthol in water samples in the presence of fluorescent interferents. Analytica Chimica Acta 2010, 677:97-107.
    • (2010) Analytica Chimica Acta , vol.677 , pp. 97-107
    • Maggio, R.M.1    Damiani, P.C.2    Olivieri, A.C.3
  • 23
    • 54749144640 scopus 로고    scopus 로고
    • Nonlinear four-way kinetic-excitation-emission fluorescence data processed by a variant of parallel factor analysis and by a neural network model achieving the second-order advantage: malonaldehyde determination in olive oil samples
    • García Reiriz A.G., Damiani P.C., Olivieri A.C., Cañada Cañada F., Muñoz de la Peña A. Nonlinear four-way kinetic-excitation-emission fluorescence data processed by a variant of parallel factor analysis and by a neural network model achieving the second-order advantage: malonaldehyde determination in olive oil samples. Analytical Chemistry 2008, 80:7248-7256.
    • (2008) Analytical Chemistry , vol.80 , pp. 7248-7256
    • García Reiriz, A.G.1    Damiani, P.C.2    Olivieri, A.C.3    Cañada Cañada, F.4    Muñoz de la Peña, A.5
  • 24
    • 28544448091 scopus 로고    scopus 로고
    • Photocatalytic degradation-excitation-emission matrix fluorescence for increasing the selectivity of polycyclic aromatic hydrocarbon analyses
    • Kim Y.C., Jordan J.A., Nahorniak M.L., Booksh K.S. Photocatalytic degradation-excitation-emission matrix fluorescence for increasing the selectivity of polycyclic aromatic hydrocarbon analyses. Analytical Chemistry 2005, 77:7679-7686.
    • (2005) Analytical Chemistry , vol.77 , pp. 7679-7686
    • Kim, Y.C.1    Jordan, J.A.2    Nahorniak, M.L.3    Booksh, K.S.4
  • 25
    • 12344268737 scopus 로고    scopus 로고
    • Fiber-optic surface plasmon resonance for vapor phase analyses
    • Nahorniak M.L., Cooper G.A., Kim Y.C., Booksh K.S. Fiber-optic surface plasmon resonance for vapor phase analyses. Analyst 2005, 130:85-93.
    • (2005) Analyst , vol.130 , pp. 85-93
    • Nahorniak, M.L.1    Cooper, G.A.2    Kim, Y.C.3    Booksh, K.S.4
  • 26
    • 8644223385 scopus 로고    scopus 로고
    • Multivariate selectivity as a metric for evaluating comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry subjected to chemometric peak deconvolution
    • Sinha A.E., Hope J.L., Prazen B.J., Fraga C.G., Nilsson E.J., Synovec R.E. Multivariate selectivity as a metric for evaluating comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry subjected to chemometric peak deconvolution. Journal of Chromatography. A 2004, 1056:145-154.
    • (2004) Journal of Chromatography. A , vol.1056 , pp. 145-154
    • Sinha, A.E.1    Hope, J.L.2    Prazen, B.J.3    Fraga, C.G.4    Nilsson, E.J.5    Synovec, R.E.6
  • 27
    • 0347284332 scopus 로고    scopus 로고
    • Trilinear chemometric analysis of two-dimensional comprehensive gas chromatography-time-of-flight mass spectrometry data
    • Sinha A.E., Fraga C.G., Prazen B.J., Synovec R.E. Trilinear chemometric analysis of two-dimensional comprehensive gas chromatography-time-of-flight mass spectrometry data. Journal of Chromatography. A 2004, 1027:269-277.
    • (2004) Journal of Chromatography. A , vol.1027 , pp. 269-277
    • Sinha, A.E.1    Fraga, C.G.2    Prazen, B.J.3    Synovec, R.E.4
  • 28
    • 33646188618 scopus 로고    scopus 로고
    • Comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry analysis of metabolites in fermenting and respiring yeast cells
    • Molher R.E., Dombek K.M., Hoggar J.C., Young E.T., Synovec R.E. Comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry analysis of metabolites in fermenting and respiring yeast cells. Analytical Chemistry 2006, 78:2700-2709.
    • (2006) Analytical Chemistry , vol.78 , pp. 2700-2709
    • Molher, R.E.1    Dombek, K.M.2    Hoggar, J.C.3    Young, E.T.4    Synovec, R.E.5
  • 29
    • 33746837634 scopus 로고    scopus 로고
    • Analysis of four-way two-dimensional liquid chromatography-diode array data: application to metabolomics
    • Porter S.E.G., Stoll D.R., Rutan S.C., Carr P.W., Cohen J.D. Analysis of four-way two-dimensional liquid chromatography-diode array data: application to metabolomics. Analytical Chemistry 2006, 78:5559-5569.
    • (2006) Analytical Chemistry , vol.78 , pp. 5559-5569
    • Porter, S.E.G.1    Stoll, D.R.2    Rutan, S.C.3    Carr, P.W.4    Cohen, J.D.5
  • 30
    • 34548650573 scopus 로고    scopus 로고
    • Trilinear decomposition method applied to removal of three-dimensional background drift in comprehensive two-dimensional separation data
    • Zhang Y., Wu H.L., Xiu A.L., Hu H.L., Zon H.F., Yu R.Q. Trilinear decomposition method applied to removal of three-dimensional background drift in comprehensive two-dimensional separation data. Journal of Chromatography. A 2007, 1167:178-183.
    • (2007) Journal of Chromatography. A , vol.1167 , pp. 178-183
    • Zhang, Y.1    Wu, H.L.2    Xiu, A.L.3    Hu, H.L.4    Zon, H.F.5    Yu, R.Q.6
  • 31
    • 79952451919 scopus 로고    scopus 로고
    • Chemometric resolution and quantification of four-way data arising from comprehensive 2D-LC-DAD analysis of human urine
    • Bailey H.P., Rutan S.C. Chemometric resolution and quantification of four-way data arising from comprehensive 2D-LC-DAD analysis of human urine. Chemometrics and Intelligent Laboratory Systems 2011, 106:131-141.
    • (2011) Chemometrics and Intelligent Laboratory Systems , vol.106 , pp. 131-141
    • Bailey, H.P.1    Rutan, S.C.2
  • 32
    • 33644839183 scopus 로고    scopus 로고
    • Analysis of three- and four-way data using multivariate curve resolution-alternating least squares with global multi-way kinetic fitting
    • Bezemer E., Rutan S.C. Analysis of three- and four-way data using multivariate curve resolution-alternating least squares with global multi-way kinetic fitting. Chemometrics and Intelligent Laboratory Systems 2006, 81:82-93.
    • (2006) Chemometrics and Intelligent Laboratory Systems , vol.81 , pp. 82-93
    • Bezemer, E.1    Rutan, S.C.2
  • 34
    • 0024034479 scopus 로고
    • Partial least-squares methods for spectral analyses. 2. Application to simulated and glass spectral data
    • Haaland D.M., Thomas E.V. Partial least-squares methods for spectral analyses. 2. Application to simulated and glass spectral data. Analytical Chemistry 1988, 60:1193-1202.
    • (1988) Analytical Chemistry , vol.60 , pp. 1193-1202
    • Haaland, D.M.1    Thomas, E.V.2
  • 35
    • 85190313827 scopus 로고
    • Residual bilinearization. Part 1: Theory and algorithms
    • Öhman J., Geladi P., Wold S.J. Residual bilinearization. Part 1: Theory and algorithms. Journal of Chemometrics 1990, 4:79-88.
    • (1990) Journal of Chemometrics , vol.4 , pp. 79-88
    • Öhman, J.1    Geladi, P.2    Wold, S.J.3
  • 36
    • 31344478850 scopus 로고    scopus 로고
    • On a versatile second-order multivariate calibration method based on partial least-squares and residual bilinearization: Second-order advantage and precision properties
    • Olivieri A.C. On a versatile second-order multivariate calibration method based on partial least-squares and residual bilinearization: Second-order advantage and precision properties. Journal of Chemometrics 2005, 19:253-265.
    • (2005) Journal of Chemometrics , vol.19 , pp. 253-265
    • Olivieri, A.C.1
  • 37
    • 55549105425 scopus 로고    scopus 로고
    • Chemometrics-assisted excitation-emission fluorescence spectroscopy on nylon membranes. Simultaneous determination of benzo[a]pyrene and dibenz[a, h]anthracene at parts-per-trillion levels in the presence of the remaining EPA PAH priority pollutants as interferences
    • Bortolato S.A., Arancibia J.A., Escandar G.M. Chemometrics-assisted excitation-emission fluorescence spectroscopy on nylon membranes. Simultaneous determination of benzo[a]pyrene and dibenz[a, h]anthracene at parts-per-trillion levels in the presence of the remaining EPA PAH priority pollutants as interferences. Analytical Chemistry 2008, 80:8276-8286.
    • (2008) Analytical Chemistry , vol.80 , pp. 8276-8286
    • Bortolato, S.A.1    Arancibia, J.A.2    Escandar, G.M.3
  • 38
    • 84972528489 scopus 로고
    • Multilinear models: applications in spectroscopy
    • Leurgans S., Ross R.T. Multilinear models: applications in spectroscopy. Statistical Sciences 1992, 7:289-319.
    • (1992) Statistical Sciences , vol.7 , pp. 289-319
    • Leurgans, S.1    Ross, R.T.2
  • 40
    • 0030775193 scopus 로고    scopus 로고
    • A weighted non-negative least squares algorithm for three-way PARAFAC factor analysis
    • Paatero P. A weighted non-negative least squares algorithm for three-way PARAFAC factor analysis. Chemometrics and Intelligent Laboratory Systems 1997, 38:223-242.
    • (1997) Chemometrics and Intelligent Laboratory Systems , vol.38 , pp. 223-242
    • Paatero, P.1
  • 41
    • 0038685059 scopus 로고    scopus 로고
    • A new efficient method for determining the number of components in PARAFAC models
    • Bro R., Kiers H.A.L. A new efficient method for determining the number of components in PARAFAC models. Journal of Chemometrics 2003, 17:274-286.
    • (2003) Journal of Chemometrics , vol.17 , pp. 274-286
    • Bro, R.1    Kiers, H.A.L.2
  • 42
    • 80055074147 scopus 로고    scopus 로고
    • The MathWorks Inc., Natick, MA
    • MATLAB 7.10 2010, The MathWorks Inc., Natick, MA.
    • (2010) MATLAB 7.10
  • 43
    • 0025895569 scopus 로고
    • Catalysis of carbaryl hydrolysis in micellar solutions of cetyltrimethylammonium bromide
    • Patel J.M., Wurster D.E. Catalysis of carbaryl hydrolysis in micellar solutions of cetyltrimethylammonium bromide. Pharmaceutical Research 1991, 8:1155-1158.
    • (1991) Pharmaceutical Research , vol.8 , pp. 1155-1158
    • Patel, J.M.1    Wurster, D.E.2
  • 44
    • 0035447407 scopus 로고    scopus 로고
    • Cramer-Rao lower bounds for low-rank decomposition of multidimensional arrays
    • Liu X., Sidiropoulos S.D. Cramer-Rao lower bounds for low-rank decomposition of multidimensional arrays. IEEE Transactions on Signal Processing 2001, 49:2074-2086.
    • (2001) IEEE Transactions on Signal Processing , vol.49 , pp. 2074-2086
    • Liu, X.1    Sidiropoulos, S.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.