메뉴 건너뛰기




Volumn , Issue , 2011, Pages 357-360

Bias field correction using grey-weighted distance transform applied on MR volumes

Author keywords

Fourier transform; Grey weighted distance; MR volumes

Indexed keywords

BIAS ARTIFACT; BIAS FIELD; DATA SETS; DISTANCE TRANSFORMS; GREY-WEIGHTED DISTANCE; MAGNITUDE SPECTRUM; MR VOLUMES; SPATIAL VARIATIONS;

EID: 80055043628     PISSN: 19457928     EISSN: 19458452     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2011.5872423     Document Type: Conference Paper
Times cited : (3)

References (16)
  • 1
    • 0033623981 scopus 로고    scopus 로고
    • Parametric estimate of intensity inho-mogeneities applied to MRI
    • M. Styner, et al., "Parametric estimate of intensity inho-mogeneities applied to MRI," IEEE Trans. Med. Imaging, vol. 19, no. 3, pp. 153-165, 2000.
    • (2000) IEEE Trans. Med. Imaging , vol.19 , Issue.3 , pp. 153-165
    • Styner, M.1
  • 3
    • 0031987382 scopus 로고    scopus 로고
    • A nonparametric method for automatic correction of intensity nonuniformity in MRI data
    • J. G. Sled, et al., "A nonparametric method for automatic correction of intensity nonuniformity in MRI data," IEEE Trans. Med. Imaging, vol. 17(1), pp. 87-97, 1998.
    • (1998) IEEE Trans. Med. Imaging , vol.17 , Issue.1 , pp. 87-97
    • Sled, J.G.1
  • 5
    • 33847774807 scopus 로고    scopus 로고
    • A review of methods for correction of intensity inhomogeneity in MRI
    • U. Vovk, et al., "A review of methods for correction of intensity inhomogeneity in MRI," IEEE Trans. Med. Imaging, vol. 26, no. 3, pp. 405-421, 2007.
    • (2007) IEEE Trans. Med. Imaging , vol.26 , Issue.3 , pp. 405-421
    • Vovk, U.1
  • 7
    • 77952283987 scopus 로고    scopus 로고
    • Automatic correction of intensity nonuniformity from sparseness of gradient distribution in medical images
    • Springer-Verlag Berlin, Heidelberg
    • Y. Zheng, et al., "Automatic correction of intensity nonuniformity from sparseness of gradient distribution in medical images," in Proceedings of the 12th International Conference on MICCAI: Part II. 2009, vol. 5762, pp. 852-859, Springer-Verlag Berlin, Heidelberg.
    • (2009) Proceedings of the 12th International Conference on MICCAI: Part II , vol.5762 , pp. 852-859
    • Zheng, Y.1
  • 8
    • 0033624997 scopus 로고    scopus 로고
    • New variants of a method of MRI scale standardization
    • L. G. Nyúl, J. K. Udupa, and X. Zhang, "New variants of a method of MRI scale standardization," IEEE Trans. Med. Imaging, vol. 19, no. 2, pp. 143-150, 2000.
    • (2000) IEEE Trans. Med. Imaging , vol.19 , Issue.2 , pp. 143-150
    • Nyúl, L.G.1    Udupa, J.K.2    Zhang, X.3
  • 10
    • 0032293085 scopus 로고    scopus 로고
    • Uniformity correction with homomor-phic filtering on region of interest
    • R. Guillemaud, "Uniformity correction with homomor-phic filtering on region of interest," in IEEE Intern. Conference on Image Processing, 1998, vol. 2, pp. 872-875.
    • (1998) IEEE Intern. Conference on Image Processing , vol.2 , pp. 872-875
    • Guillemaud, R.1
  • 12
    • 0030142754 scopus 로고    scopus 로고
    • New geodesic distance transforms for gray-scale images
    • P. J. Toivanen, "New geodesic distance transforms for gray-scale images," Pattern Recognition Letters, vol. 17(5), pp. 437-450, 1996.
    • (1996) Pattern Recognition Letters , vol.17 , Issue.5 , pp. 437-450
    • Toivanen, P.J.1
  • 14
    • 0043031050 scopus 로고    scopus 로고
    • Fuzzy distance transform: Theory, algorithms, and applications
    • P. K. Saha, et al., "Fuzzy distance transform: Theory, algorithms, and applications," Computer Vision and Image Understanding, vol. 86(3), pp. 171-190, 2002.
    • (2002) Computer Vision and Image Understanding , vol.86 , Issue.3 , pp. 171-190
    • Saha, P.K.1
  • 15
    • 80055055936 scopus 로고    scopus 로고
    • An iterative method for nonuniform illumination correction based on the gray-weighted distance transform of the magnitude spectrum
    • M. K. Khan, et al., "An Iterative Method for Nonuniform Illumination Correction Based on the Gray-weighted Distance Transform of the Magnitude Spectrum," Submitted for Publication, 2011.
    • (2011) Submitted for Publication
    • Khan, M.K.1
  • 16
    • 0033233097 scopus 로고    scopus 로고
    • MRI simulation-based evaluation of image-processing and classification methods
    • Nov.
    • R. K. Kwan, A. C. Evans, and G. B. Pike, "MRI simulation-based evaluation of image-processing and classification methods," IEEE Trans. Med. Imaging, vol. 18, no. 11, pp. 1085-1097, Nov. 1999.
    • (1999) IEEE Trans. Med. Imaging , vol.18 , Issue.11 , pp. 1085-1097
    • Kwan, R.K.1    Evans, A.C.2    Pike, G.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.