Volumn , Issue , 2011, Pages 1223-1226

Whole body nonrigid CT-PET registration using weighted demons

Author keywords

Whole body PET CT image fusion

Indexed keywords

COMPUTED TOMOGRAPHY; DEFORMABLE REGISTRATION; IMAGE CHARACTERISTICS; IMAGING PROTOCOL; NON-RIGID; PET IMAGES; RAT IMAGES; REGISTRATION METHODS; SIMILARITY MEASURE; STANDARD METHOD; WHOLE BODY PET-CT IMAGE FUSION; WHOLE-BODY;

EID: 80055030228     PISSN: 19457928     EISSN: 19458452     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2011.5872622     Document Type: Conference Paper
Times cited : (5)

References (9)
  • 2
    • 0031211971 scopus 로고    scopus 로고
    • Utilization of 3-D elastic transformation in the registration of chest x-ray CT and whole body PET
    • Tai, Y.-C., Lin, K.P., Hoh, C.K., Huang. S.C.H., Hoffman, E.J.: Utilization of 3-D elastic transformation in the registration of chest x-ray CT and whole body PET, IEEE Trans Nucl Sci., 44, 1606-1612 (1997)
    • (1997) IEEE Trans Nucl Sci. , vol.44 , pp. 1606-1612
    • Tai, Y.-C.1    Lin, K.P.2    Hoh, C.K.3    Huang, S.C.H.4    Hoffman, E.J.5
  • 3
    • 27744442364 scopus 로고    scopus 로고
    • Automated 3-dimensional elastic registration of whole-body PET and CT from separate or combined scanners
    • Shekhar, R., Walimbe, V., Raja, V., Kanvinde, M., Wu, G., Bybel, B.: Automated 3-Dimensional Elastic Registration of Whole-Body PET and CT from Separate or Combined Scanners, Journal of Nuclear Medicine, 46, 1488-1496 (2005)
    • (2005) Journal of Nuclear Medicine , vol.46 , pp. 1488-1496
    • Shekhar, R.1    Walimbe, V.2    Raja, V.3    Kanvinde, M.4    Wu, G.5    Bybel, B.6
  • 4
    • 0036735359 scopus 로고    scopus 로고
    • Comparison of mutual information-based warping accuracy for fusing body CT and PET by 2 methods: CT mapped onto PET emission scan versus CT mapped onto PET transmission scan
    • Skalski, J., Wahl, R. L., Meyer, C. R.: Comparison of mutual information-based warping accuracy for fusing body CT and PET by 2 methods: CT mapped onto PET emission scan versus CT mapped onto PET transmission scan, Journal of Nuclear Medicine, 43, 1184-1187 (2002)
    • (2002) Journal of Nuclear Medicine , vol.43 , pp. 1184-1187
    • Skalski, J.1    Wahl, R.L.2    Meyer, C.R.3
  • 5
    • 0003414247 scopus 로고
    • Fast non-rigid matching of 3D medical images
    • Sophia Antipolis, France
    • Thirion, J. P.: Fast non-rigid matching of 3D medical images, Technical Report 2547, INRIA, Sophia Antipolis, France (1995)
    • (1995) Technical Report 2547, INRIA
    • Thirion, J.P.1
  • 8
    • 0032762144 scopus 로고    scopus 로고
    • An overlap invariant entropy measure of 3D medical image alignment
    • Studholme, C., Hill, D. L. G., Hawkes, D. J.: An overlap invariant entropy measure of 3D medical image alignment, Pattern Recognition, 32, 71-86 (1999)
    • (1999) Pattern Recognition , vol.32 , pp. 71-86
    • Studholme, C.1    Hill, D.L.G.2    Hawkes, D.J.3
  • 9
    • 0033101358 scopus 로고    scopus 로고
    • Object matching algorithm using robust hausdorff distance measures
    • Sim, D.-G., Kwon, O.-K., Park, R.-H.: Object matching algorithm using robust Hausdorff distance measures, IEEE Trans. Image Proc., TIP-8(11), 425-429 (1999)
    • (1999) IEEE Trans. Image Proc. , vol.TIP-8 , Issue.11 , pp. 425-429
    • Sim, D.-G.1    Kwon, O.-K.2    Park, R.-H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.