-
1
-
-
85008035331
-
Visual pros thesis
-
J. D. Weiland and M. S. Humayun, "Visual prosthesis," Proc. IEEE, vol. 96, no. 7, pp. 1076-1084, 2008.
-
(2008)
Proc. IEEE
, vol.96
, Issue.7
, pp. 1076-1084
-
-
Weiland, J.D.1
Humayun, M.S.2
-
2
-
-
10444220925
-
A very low-power CMOS mixed-signal IC for implantable pacemaker applications
-
Dec.
-
L. S. Y. Wong et al., "A very low-power CMOS mixed-signal IC for implantable pacemaker applications," IEEE J. Solid-State Circuits, vol. 39, no. 12, pp. 2446-2456, Dec. 2004.
-
(2004)
IEEE J. Solid-State Circuits
, vol.39
, Issue.12
, pp. 2446-2456
-
-
Wong, L.S.Y.1
-
3
-
-
19944414322
-
Design of a subcutaneous implantable biochip for monitoring of glucose and lactate
-
DOI 10.1109/JSEN.2005.846173
-
A. Guiseppi-Elie, S. Brahim, G. Slaughter, and K. R. Ward, "Design of a subcutaneous implantable biochip for monitoring of glucose and lactate," IEEE Sensors J., vol. 5, no. 3, pp. 345-355, Mar. 2005. (Pubitemid 40751324)
-
(2005)
IEEE Sensors Journal
, vol.5
, Issue.3
, pp. 345-355
-
-
Guiseppi-Elie, A.1
Brahim, S.2
Slaughter, G.3
Ward, K.R.4
-
4
-
-
0141479956
-
Chronic, multisite, multielectrode recordings in macaque monkeys
-
DOI 10.1073/pnas.1934665100
-
M. A. L. Nicolelis et al., "Chronic, multisite, multielectrode recordings in macaque monkeys," in Proc. Natl. Acad. Sci. U.S.A., 2003, vol. 100, no. 19, pp. 11041-11046. (Pubitemid 37140149)
-
(2003)
Proceedings of the National Academy of Sciences of the United States of America
, vol.100
, Issue.19
, pp. 11041-11046
-
-
Nicolelis, M.A.L.1
Dimitrov, D.2
Carmena, J.M.3
Crist, R.4
Lehew, G.5
Kralik, J.D.6
Wise, S.P.7
-
5
-
-
0030575296
-
Single unit recording capabilities of a 100 microelectrode array
-
DOI 10.1016/S0006-8993(96)00321-6
-
C. T. Nordhausen, E. M. Maynard, and R. A. Normann, "Single unit recording capabilities of a 100 microelectrode array," Brain Research, vol. 726, pp. 129-140, 1996. (Pubitemid 26292238)
-
(1996)
Brain Research
, vol.726
, Issue.1-2
, pp. 129-140
-
-
Nordhausen, C.T.1
Maynard, E.M.2
Normann, R.A.3
-
6
-
-
61849140035
-
A 3D slim-base probe array for in vivo recorded neuron activity
-
A. A. A. Aarts et al., "A 3D slim-base probe array for in vivo recorded neuron activity," in Proc. IEEE EMBC'08, 2008, pp. 5798-5801.
-
(2008)
Proc. IEEE EMBC'08
, pp. 5798-5801
-
-
Aarts, A.A.A.1
-
7
-
-
2442708539
-
Wireless implantable microsystems: High-density electronic interfaces to the nervous system
-
DOI 10.1109/JPROC.2003.820544, Biomedical Applications for Mems and Microfluidics
-
K. D. Wise, D. J. Anderson, J. F. Hetke, D. R. Kipke, and K. Najafi, "Wireless implantable microsystems: High-density electronic interfaces to the nervous system," Proc. IEEE, vol. 92, no. 1, pp. 76-97, 2004. (Pubitemid 40890773)
-
(2004)
Proceedings of the IEEE
, vol.92
, Issue.1
, pp. 76-97
-
-
Wise, K.D.1
Anderson, D.J.2
Hetke, J.F.3
Kipke, D.R.4
Najafi, K.5
-
8
-
-
33846258717
-
A low-power integrated circuit for a wireless 100-electrode neural recording system
-
DOI 10.1109/JSSC.2006.886567
-
R. R. Harrison et al., "A low-power integrated circuit for a wireless 100-electrode neural recording system," IEEE J. Solid-State Circuits, vol. 42, no. 1, pp. 123-133, Jan. 2007. (Pubitemid 46103876)
-
(2007)
IEEE Journal of Solid-State Circuits
, vol.42
, Issue.1
, pp. 123-133
-
-
Harrison, R.R.1
Watkins, P.T.2
Kier, R.J.3
Lovejoy, R.O.4
Black, D.J.5
Greger, B.6
Solzbacher, F.7
-
9
-
-
0033230150
-
A wireless near-infrared energy system for medical implants
-
K. Murakawa, M. Kobayashi, O. Nakamura, and S. Kawata, "A wireless near-infrared energy system for medical implants," IEEE Eng. Med. Biol. Mag., vol. 18, no. 6, pp. 70-72, 1999.
-
(1999)
IEEE Eng. Med. Biol. Mag.
, vol.18
, Issue.6
, pp. 70-72
-
-
Murakawa, K.1
Kobayashi, M.2
Nakamura, O.3
Kawata, S.4
-
10
-
-
78650801349
-
In-vitro platform to study ultrasound as source for wireless energy transfer and communication for implanted medical devices
-
F. Mazzilli et al., "In-vitro platform to study ultrasound as source for wireless energy transfer and communication for implanted medical devices," in Proc. IEEE EMBC'10, 2010, pp. 3751-3754.
-
(2010)
Proc. IEEE EMBC'10
, pp. 3751-3754
-
-
Mazzilli, F.1
-
11
-
-
36348966760
-
A wide-band power-efficient inductive wireless link for implantable microelectronic devices using multiple carriers
-
DOI 10.1109/TCSI.2007.905187
-
M. Ghovanloo and S. Atluri, "A wide-band power-efficient inductive wireless link for implantable microelectronic devices using multiple carriers," IEEE Trans. Circuits Syst. I, vol. 54, no. 10, pp. 2211-2221, Oct. 2007. (Pubitemid 350141867)
-
(2007)
IEEE Transactions on Circuits and Systems I: Regular Papers
, vol.54
, Issue.10
, pp. 2211-2221
-
-
Ghovanloo, M.1
Atluri, S.2
-
12
-
-
29344474930
-
Power harvesting and telemetry in CMOS for implanted devices
-
DOI 10.1109/TCSI.2005.858183, Biomedical Circuits and Systems: A New Wave of Technology
-
C. Sauer, M. Stanacevic, G. Cauwenberghs, and N. Thakor, "Power harvesting and telemetry inCMOSfor implanted devices," IEEE Trans. Circuits Syst. I, vol. 52, no. 12, pp. 2605-2613, Dec. 2005. (Pubitemid 43000816)
-
(2005)
IEEE Transactions on Circuits and Systems I: Regular Papers
, vol.52
, Issue.12
, pp. 2605-2613
-
-
Sauer, C.1
Stanacevic, M.2
Cauwenberghs, G.3
Thakor, N.4
-
13
-
-
0030200060
-
Geometric approach for coupling enhancement of magnetically coupled coils
-
DOI 10.1109/10.503178
-
C. M. Zierhofer and E. S. Hochmair, "Geometric approach for coupling enhancement of magnetically coupled coils," IEEE Trans. Biomed. Eng., vol. 43, no. 7, pp. 708-714, Jul. 1996. (Pubitemid 26231501)
-
(1996)
IEEE Transactions on Biomedical Engineering
, vol.43
, Issue.7
, pp. 708-714
-
-
Zierhofer, C.M.1
Hochmair, E.S.2
-
14
-
-
34548827377
-
Designing efficient inductive power links for implantable devices
-
4253079, 2007 IEEE International Symposium on Circuits and Systems, ISCAS 2007
-
R. R. Harrison, "Designing efficient inductive power links for implantable devices," in Proc. IEEE ISCAS'07, 2007, pp. 2080-2083. (Pubitemid 47448949)
-
(2007)
Proceedings - IEEE International Symposium on Circuits and Systems
, pp. 2080-2083
-
-
Harrison, R.R.1
-
15
-
-
75049084902
-
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
-
Oct.
-
U. Jow and M. Ghovanloo, "Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments," Trans. Biomed. Circuits. Syst., vol. 3, no. 5, pp. 339-347, Oct. 2009.
-
(2009)
Trans. Biomed. Circuits. Syst.
, vol.3
, Issue.5
, pp. 339-347
-
-
Jow, U.1
Ghovanloo, M.2
-
16
-
-
51849104548
-
Improvement of power efficiency of inductive links for implantable devices
-
K. M. Silay, C. Dehollain, and M. Declercq, "Improvement of power efficiency of inductive links for implantable devices," in Proc. PRIME'08 Conf., 2008, pp. 229-232.
-
(2008)
Proc. PRIME'08 Conf.
, pp. 229-232
-
-
Silay, K.M.1
Dehollain, C.2
Declercq, M.3
-
17
-
-
80055049422
-
-
National Library of Medicine USA. The visible human project, [Online]. Available
-
National Library of Medicine USA., "The visible human project." 2008. [Online]. Available: http://www.nlm.nih.gov/research/visible/
-
(2008)
-
-
-
18
-
-
63649149879
-
Orthogonally oriented coils for minimization of cross-coupling in cortical implants
-
K. M. Silay, C. Dehollain, and M. Declercq, "Orthogonally oriented coils for minimization of cross-coupling in cortical implants," in Proc. IEEE BioCAS'08, 2008, pp. 109-112.
-
(2008)
Proc. IEEE BioCAS'08
, pp. 109-112
-
-
Silay, K.M.1
Dehollain, C.2
Declercq, M.3
-
19
-
-
79951882481
-
Inductive power link for a wireless cortical implant with biocompatible packaging
-
K. M. Silay, C. Dehollain, and M. Declercq, "Inductive power link for a wireless cortical implant with biocompatible packaging," in Proc. IEEE Sensors'10, 2010, pp. 94-98.
-
(2010)
Proc. IEEE Sensors'10
, pp. 94-98
-
-
Silay, K.M.1
Dehollain, C.2
Declercq, M.3
-
20
-
-
0031294321
-
EM radiation behavior upon biological tissues in a radio-frequency power transfer link for a cortical visual implant
-
P. Vaillancourt, A. Djemouai, J. F. Harvey, and M. Sawan, "EM radiation behavior upon biological tissues in a radio-frequency power transfer link for a cortical visual implant," in Proc. IEEE EMBC'97, 1997, pp. 2499-2502.
-
(1997)
Proc. IEEE EMBC'97
, pp. 2499-2502
-
-
Vaillancourt, P.1
Djemouai, A.2
Harvey, J.F.3
Sawan, M.4
-
21
-
-
0016521160
-
Class E-A new class of high-efficiency tuned single-ended switching power amplifiers
-
Jun.
-
N. O. Sokal and A. D. Sokal, "Class E-A new class of high-efficiency tuned single-ended switching power amplifiers," IEEE J. Solid-State Circuits, vol. 10, no. 3, pp. 168-176, Jun. 1975.
-
(1975)
IEEE J. Solid-State Circuits
, vol.10
, Issue.3
, pp. 168-176
-
-
Sokal, N.O.1
Sokal, A.D.2
-
22
-
-
20144384534
-
An optimal design methodology for inductive power link with Class-E amplifier
-
DOI 10.1109/TCSI.2005.846208
-
G. Kendir et al., "An optimal design methodology for inductive power link with class-E amplifier," IEEE Trans. Circuits Syst. I, vol. 52, no. 5, pp. 857-866, May 2005. (Pubitemid 40773612)
-
(2005)
IEEE Transactions on Circuits and Systems I: Regular Papers
, vol.52
, Issue.5
, pp. 857-866
-
-
Kendir, G.A.1
Liu, W.2
Wang, G.3
Sivaprakasam, M.4
Bashirullah, R.5
Humayun, M.S.6
Weiland, J.D.7
-
23
-
-
77955091787
-
A wireless-implantable microsystem for continuous blood glucose monitoring
-
Jun.
-
M. M. Ahmadi and G. A. Jullien, "A wireless-implantable microsystem for continuous blood glucose monitoring," Trans. Biomed. Circuits. Syst., vol. 3, no. 3, pp. 169-180, Jun. 2009.
-
(2009)
Trans. Biomed. Circuits. Syst.
, vol.3
, Issue.3
, pp. 169-180
-
-
Ahmadi, M.M.1
Jullien, G.A.2
-
24
-
-
8344259144
-
Fully integrated wideband high-current rectifiers for inductively powered devices
-
Nov.
-
M. Ghovanloo and K. Najafi, "Fully integrated wideband high-current rectifiers for inductively powered devices," IEEE J. Solid-State Circuits, vol. 39, no. 11, pp. 1976-1984, Nov. 2004.
-
(2004)
IEEE J. Solid-State Circuits
, vol.39
, Issue.11
, pp. 1976-1984
-
-
Ghovanloo, M.1
Najafi, K.2
-
25
-
-
34548359161
-
Efficiency-enhanced CMOS rectifier for wireless telemetry
-
DOI 10.1049/el:20071822
-
C.-L. Chen, K.-H. Chen, and S.-I. Liu, "Efficiency-enhanced CMOS rectifier for wireless telemetry," Electron. Lett., vol. 43, no. 18, pp. 976-978, 2007. (Pubitemid 47346590)
-
(2007)
Electronics Letters
, vol.43
, Issue.18
, pp. 976-978
-
-
Chen, C.-L.1
Chen, K.-H.2
Liu, S.-I.3
-
26
-
-
70350144772
-
Load optimization of an inductive power link for remote powering of biomedical implants
-
K. M. Silay et al., "Load optimization of an inductive power link for remote powering of biomedical implants," in Proc. IEEE ISCAS'09, 2009, pp. 533-536.
-
(2009)
Proc. IEEE ISCAS'09
, pp. 533-536
-
-
Silay, K.M.1
-
27
-
-
77957304076
-
Low-distortion switched-capacitor event-driven analogue to-digital converter
-
V. Majidzadeh, A. Schmid, and Y. Leblebici, "Low-distortion switched-capacitor event-driven analogue to-digital converter," Electron. Lett., vol. 46, no. 20, pp. 1373-1374, 2010.
-
(2010)
Electron. Lett.
, vol.46
, Issue.20
, pp. 1373-1374
-
-
Majidzadeh, V.1
Schmid, A.2
Leblebici, Y.3
-
28
-
-
79958267349
-
A fully on-chip LDO voltage regulator with 37 dB PSRR at 1 MHz for remotely powered biomedical implants
-
V. Majidzadeh, K. M. Silay,A. Schmid, C. Dehollain, and Y. Leblebici, "A fully on-chip LDO voltage regulator with 37 dB PSRR at 1 MHz for remotely powered biomedical implants," Analog Integr. Circ. Sig. Process., vol. 67, no. 2, pp. 157-168, 2011.
-
(2011)
Analog Integr. Circ. Sig. Process.
, vol.67
, Issue.2
, pp. 157-168
-
-
Majidzadeh, V.1
Silay, K.M.2
Schmid, A.3
Dehollain, C.4
Leblebici, Y.5
-
29
-
-
80055031567
-
Numerical thermal analysis of a wireless cortical implant with two-body packaging
-
K. M. Silay, C. Dehollain, and M. Declercq, "Numerical thermal analysis of a wireless cortical implant with two-body packaging," BioNanoScience, vol. 1, no. 3, pp. 78-88, 2011.
-
(2011)
BioNanoScience
, vol.1
, Issue.3
, pp. 78-88
-
-
Silay, K.M.1
Dehollain, C.2
Declercq, M.3
-
30
-
-
33645238778
-
Characterization of polydimethylsiloxane (PDMS) properties for biomedical micro/nanosystems
-
A. Mata, A. Fleischman, and S. Roy, "Characterization of polydimethylsiloxane (PDMS) properties for biomedical micro/nanosystems," Biomed. Microdevices, vol. 7, no. 4, pp. 281-293, 2005.
-
(2005)
Biomed. Microdevices
, vol.7
, Issue.4
, pp. 281-293
-
-
Mata, A.1
Fleischman, A.2
Roy, S.3
-
31
-
-
80053924626
-
In vivo biocompatibility of three potential intraperitoneal implants
-
doi: 10.1002/mabi.201100077, to be published
-
S. Defrère et al., "In vivo biocompatibility of three potential intraperitoneal implants," Macromolecular Bioscience, 2011, doi: 10.1002/mabi.201100077, to be published.
-
(2011)
Macromolecular Bioscience
-
-
Defrère, S.1
-
32
-
-
0017368305
-
Parylene as a chronically stable, reproducible microelectrode insulator
-
G. E. Loeb, M. J. Bak, M. Salcman, and E. M. Schmidt, "Parylene as a chronically stable, reproducible microelectrode insulator," IEEE Trans. Biomed. Eng., vol. BME-24, no. 2, pp. 121-128, Mar. 1977. (Pubitemid 8125041)
-
(1977)
IEEE Transactions on Biomedical Engineering
, vol.24
, Issue.2
, pp. 121-128
-
-
Loeb, G.E.1
Bak, M.J.2
Salcman, M.3
Schmidt, E.M.4
-
33
-
-
0023864665
-
Long-term implants of Parylene-C coated microelectrodes
-
E. Schmidt, J. Mcintosh, and M. Bak, "Long-term implants of Parylene- C coated microelectrodes," Med. Biol. Eng. Comput., vol. 26, no. 1, pp. 96-101, 1988. (Pubitemid 18033365)
-
(1988)
Medical and Biological Engineering and Computing
, vol.26
, Issue.1
, pp. 96-101
-
-
Schmidt, E.M.1
McIntosh, J.S.2
Bak, M.J.3
-
34
-
-
33745699676
-
Scalable high leadcount Parylene package for retinal prostheses
-
D. Rodger, J. Weiland, M. Humayun, and Y.-C. Tai, "Scalable high leadcount Parylene package for retinal prostheses," Sens. Actuators B: Chem., vol. 117, no. 1, pp. 107-114, 2006.
-
(2006)
Sens. Actuators B: Chem.
, vol.117
, Issue.1
, pp. 107-114
-
-
Rodger, D.1
Weiland, J.2
Humayun, M.3
Tai, Y.-C.4
-
35
-
-
79451472448
-
Design and optimization of resonance-based efficient wireless power delivery systems for biomedical implants
-
Feb.
-
A. K. RamRakhyani, S. Mirabbasi, and M. Chiao, "Design and optimization of resonance-based efficient wireless power delivery systems for biomedical implants," Trans. Biomed. Circuits Syst., vol. 5, no. 1, pp. 48-63, Feb. 2011.
-
(2011)
Trans. Biomed. Circuits Syst.
, vol.5
, Issue.1
, pp. 48-63
-
-
RamRakhyani, A.K.1
Mirabbasi, S.2
Chiao, M.3
-
36
-
-
0029909341
-
The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
-
DOI 10.1088/0031-9155/41/11/002
-
S. Gabriel, R. W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz," Phys. Med. Biol., vol. 41, no. 11, pp. 2251-2269, 1996. (Pubitemid 26376902)
-
(1996)
Physics in Medicine and Biology
, vol.41
, Issue.11
, pp. 2251-2269
-
-
Gabriel, S.1
Lau, R.W.2
Gabriel, C.3
-
37
-
-
80055052945
-
-
Italian National Research Council, Dielectric properties of body tissues, [Online]. Available
-
Italian National Research Council, "Dielectric properties of body tissues." 2010. [Online]. Available: http://niremf.ifac.cnr.it/tissprop/
-
(2010)
-
-
|