메뉴 건너뛰기




Volumn 27, Issue 7, 2011, Pages 931-937

Assessment of the serial changes of vessel wall contents in atherosclerotic coronary lesion with bioresorbable everolimus-eluting vascular scaffolds using Shin's method: An IVUS study

Author keywords

Bioabsorbable stent; Bioresorption; Virtual Histology intravascular ultrasound

Indexed keywords

EVEROLIMUS; TISSUE SCAFFOLD;

EID: 80055020274     PISSN: 15695794     EISSN: 15730743     Source Type: Journal    
DOI: 10.1007/s10554-010-9739-4     Document Type: Article
Times cited : (5)

References (6)
  • 1
    • 61849110613 scopus 로고    scopus 로고
    • A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods
    • 19286089 10.1016/S0140-6736(09)60325-1 1:CAS:528:DC%2BD1MXjtFKqtro%3D
    • PW Serruys JA Ormiston Y Onuma, et al. 2009 A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods Lancet 373 897 910 19286089 10.1016/S0140-6736(09) 60325-1 1:CAS:528:DC%2BD1MXjtFKqtro%3D
    • (2009) Lancet , vol.373 , pp. 897-910
    • Serruys, P.W.1    Ormiston, J.A.2    Onuma, Y.3
  • 2
    • 63049099539 scopus 로고    scopus 로고
    • Assessment of the absorption process following bioabsorbable everolimus-eluting stent implantation: Temporal changes in strain values and tissue composition using intravascular ultrasound radiofrequency data analysis. A substudy of the ABSORB clinical trial
    • 19284065 10.4244/EIJV4I4A77
    • HM Garcia-Garcia N Gonzalo R Pawar, et al. 2009 Assessment of the absorption process following bioabsorbable everolimus-eluting stent implantation: temporal changes in strain values and tissue composition using intravascular ultrasound radiofrequency data analysis. A substudy of the ABSORB clinical trial EuroIntervention 4 443 448 19284065 10.4244/EIJV4I4A77
    • (2009) EuroIntervention , vol.4 , pp. 443-448
    • Garcia-Garcia, H.M.1    Gonzalo, N.2    Pawar, R.3
  • 3
    • 77951125989 scopus 로고    scopus 로고
    • A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis
    • 20063068 10.1007/s10554-009-9567-6
    • ES Shin HM Garcia-Garcia PW Serruys 2010 A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis Int J Cardiovasc Imaging 26 387 396 20063068 10.1007/s10554-009-9567-6
    • (2010) Int J Cardiovasc Imaging , vol.26 , pp. 387-396
    • Shin, E.S.1    Garcia-Garcia, H.M.2    Serruys, P.W.3
  • 4
    • 40649083620 scopus 로고    scopus 로고
    • A bioabsorbable everolimus-eluting coronary stent system for patients with single de novo coronary artery lesions (ABSORB): A prospective open-label trial
    • 18342684 10.1016/S0140-6736(08)60415-8 1:CAS:528:DC%2BD1cXjtlSrt70%3D
    • JA Ormiston PW Serruys E Regar, et al. 2008 A bioabsorbable everolimus-eluting coronary stent system for patients with single de novo coronary artery lesions (ABSORB): a prospective open-label trial Lancet 371 899 907 18342684 10.1016/S0140-6736(08)60415-8 1:CAS:528:DC%2BD1cXjtlSrt70%3D
    • (2008) Lancet , vol.371 , pp. 899-907
    • Ormiston, J.A.1    Serruys, P.W.2    Regar, E.3
  • 5
    • 14844362253 scopus 로고    scopus 로고
    • Artifact-free coronary magnetic resonance angiography and coronary vessel wall imaging in the presence of a new, metallic, coronary magnetic resonance imaging stent
    • 15723984 10.1161/01.CIR.0000156462.97532.8F
    • E Spuentrup A Ruebben A Mahnken, et al. 2005 Artifact-free coronary magnetic resonance angiography and coronary vessel wall imaging in the presence of a new, metallic, coronary magnetic resonance imaging stent Circulation 111 1019 1026 15723984 10.1161/01.CIR.0000156462.97532.8F
    • (2005) Circulation , vol.111 , pp. 1019-1026
    • Spuentrup, E.1    Ruebben, A.2    Mahnken, A.3
  • 6
    • 33845643734 scopus 로고    scopus 로고
    • Reproducibility of intravascular ultrasound radiofrequency data analysis: Implications for the design of longitudinal studies
    • 16575482 10.1007/s10554-006-9080-0
    • GA Rodriguez-Granillo S Vaina HM Garcia-Garcia, et al. 2006 Reproducibility of intravascular ultrasound radiofrequency data analysis: implications for the design of longitudinal studies Int J Cardiovasc Imaging 22 621 631 16575482 10.1007/s10554-006-9080-0
    • (2006) Int J Cardiovasc Imaging , vol.22 , pp. 621-631
    • Rodriguez-Granillo, G.A.1    Vaina, S.2    Garcia-Garcia, H.M.3