메뉴 건너뛰기




Volumn 37, Issue 9, 2011, Pages 2205-2210

Breakdown characteristics of oil-pressboard insulation in converter transformer under composite electric field and its test method

Author keywords

AC voltage test; Breakdown field strength; Composite electric field; Converter transformer; DC voltage test; HVDC; Oil and pressboard insulation

Indexed keywords

AC VOLTAGE; BREAKDOWN FIELD; COMPOSITE ELECTRIC FIELD; CONVERTER TRANSFORMERS; DC VOLTAGE; HVDC; PRESSBOARD INSULATION;

EID: 80055008712     PISSN: 10036520     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (16)

References (23)
  • 1
    • 30544434206 scopus 로고    scopus 로고
    • Present status and prospect of HVDC transmission in China
    • SHU Yin-biao. Present status and prospect of HVDC transmission in China[J]. High Voltage Engineering, 2004, 30(11): 1-2, 20.
    • (2004) High Voltage Engineering , vol.30 , Issue.11
    • Shu, Y.-B.1
  • 2
    • 33845721416 scopus 로고    scopus 로고
    • Beijing, China: China Economic Publishing House
    • LIU Zhen-ya. Ultra-high voltage grid[M]. Beijing, China: China Economic Publishing House, 2005.
    • (2005) Ultra-High Voltage Grid
    • Liu, Z.-Y.1
  • 3
    • 33644643519 scopus 로고    scopus 로고
    • Development of ultra-high voltage transmission technology in China southern power grid
    • SHANG Chun. Development of ultra-high voltage transmission technology in China southern power grid[J]. High Voltage Engineering, 2006, 32(1): 35-37.
    • (2006) High Voltage Engineering , vol.32 , Issue.1 , pp. 35-37
    • Shang, C.1
  • 4
    • 78649375180 scopus 로고    scopus 로고
    • Summary of ultra high voltage direct current transmission technology
    • LI Xiao-li, CHEN Zu-sheng. Summary of ultra high voltage direct current transmission technology[J]. Guangxi Electric Power, 2009(1): 23-26.
    • (2009) Guangxi Electric Power , Issue.1 , pp. 23-26
    • Li, X.-L.1    Chen, Z.-S.2
  • 6
    • 70349173085 scopus 로고    scopus 로고
    • Design of ±800 kV DC UHV transmission line
    • LI Yong-wei, ZHOU Kang, LI Li, et al. Design of ±800 kV DC UHV transmission line[J]. High Voltage Engineering, 2009, 35(7): 1518-1524.
    • (2009) High Voltage Engineering , vol.35 , Issue.7 , pp. 1518-1524
    • Li, Y.-W.1    Zhou, K.2    Li, L.3
  • 7
    • 77950564610 scopus 로고    scopus 로고
    • Analysis on dynamic characteristic of control mode for ±800 kV Yun-Guang UHVDC
    • LIU Ke-zhen, SHU Hong-chun, SUN Shi-yun, et al. Analysis on dynamic characteristic of control mode for ±800 kV Yun-Guang UHVDC[J]. High Voltage Engineering, 2010, 36(1): 190-195.
    • (2010) High Voltage Engineering , vol.36 , Issue.1 , pp. 190-195
    • Liu, K.-Z.1    Shu, H.-C.2    Sun, S.-Y.3
  • 8
    • 80054977046 scopus 로고    scopus 로고
    • R&D of converter transformer for±800 kV HVDC power transmission project
    • SUN You-liang, WANG Qing-pu, LI Wen-ping, et al. R&D of converter transformer for±800 kV HVDC power transmission project[J]. Electrical Equipment, 2006, 7(11): 17-20.
    • (2006) Electrical Equipment , vol.7 , Issue.11 , pp. 17-20
    • Sun, Y.-L.1    Wang, Q.-P.2    Li, W.-P.3
  • 9
    • 78651360361 scopus 로고    scopus 로고
    • Study on main insulation system of converter transformer for ±800 kV HVDC power transmission project
    • LI Wen-ping, CHEN Zhi-wei, SONG Xiu-sheng, et al. Study on main insulation system of converter transformer for ±800 kV HVDC power transmission project[J]. Electrical Equipment, 2007, 8(3): 5-7.
    • (2007) Electrical Equipment , vol.8 , Issue.3 , pp. 5-7
    • Li, W.-P.1    Chen, Z.-W.2    Song, X.-S.3
  • 10
    • 77952846015 scopus 로고    scopus 로고
    • Main insulation research of 800 kV HVDC converter transformer
    • LUO Qing-lin. Main insulation research of 800 kV HVDC converter transformer[J]. Transformer, 2009, 46(11): 7-9, 31.
    • (2009) Transformer , vol.46 , Issue.11
    • Luo, Q.-L.1
  • 11
    • 0022752712 scopus 로고
    • Recommended dielectric tests and test procedures for converter transformers and smoothing reactors
    • IEEE Working Group on Dielectric Tests for HVDC Stressed Transformers and Reactors
    • IEEE Working Group on Dielectric Tests for HVDC Stressed Transformers and Reactors. Recommended dielectric tests and test procedures for converter transformers and smoothing reactors[J]. IEEE Transactions on Power Delivery, 1986, 1(3): 161-166.
    • (1986) IEEE Transactions on Power Delivery , vol.1 , Issue.3 , pp. 161-166
  • 12
    • 65749103138 scopus 로고    scopus 로고
    • Situation & overview of HVDC system localization of China
    • CHANG Hao. Situation & overview of HVDC system localization of China[J]. High Voltage Engineering, 2004, 30(11): 3-4, 36.
    • (2004) High Voltage Engineering , vol.30 , Issue.11
    • Chang, H.1
  • 13
    • 0016895196 scopus 로고
    • Partial discharge characteristics of oil-immersed insulation systems under DC, combined AC-DC and DC reversed polarity voltage
    • Takahashi E, Tsutsumi Y, Okuyama K, et al. Partial discharge characteristics of oil-immersed insulation systems under DC, combined AC-DC and DC reversed polarity voltage[J]. IEEE Transactions on Power Apparatus and Systems, 1976, 95(1): 411-420.
    • (1976) IEEE Transactions on Power Apparatus and Systems , vol.95 , Issue.1 , pp. 411-420
    • Takahashi, E.1    Tsutsumi, Y.2    Okuyama, K.3
  • 14
    • 0025417220 scopus 로고
    • Surface electric strength of processed pressboard under composite AC and DC and convebtional stresses
    • Raghuveer M R, Kolaczkowski Z, Jin Weifang, et al. Surface electric strength of processed pressboard under composite AC and DC and convebtional stresses[J]. IEEE Transactions on Electrical Insulation, 1990, 25(2): 341-350.
    • (1990) IEEE Transactions on Electrical Insulation , vol.25 , Issue.2 , pp. 341-350
    • Raghuveer, M.R.1    Kolaczkowski, Z.2    Jin, W.3
  • 16
    • 0023363736 scopus 로고
    • Electrical breakdown strength of paper-oil insulation under pulsating voltages
    • Nowaczyk H, Grzybowski S, Kuffel E. Electrical breakdown strength of paper-oil insulation under pulsating voltages[J]. IEEE Transactions on Electrical Insulation, 1987, 22(3): 249-253.
    • (1987) IEEE Transactions on Electrical Insulation , vol.22 , Issue.3 , pp. 249-253
    • Nowaczyk, H.1    Grzybowski, S.2    Kuffel, E.3
  • 18
    • 80054992804 scopus 로고    scopus 로고
    • Converter transformer. Part 2: Transformers for HVDC applications
    • IEC61378-2
    • IEC61378-2 Converter transformer part 2: transformers for HVDC applications[S], 2001.
    • (2001)
  • 19
    • 58149113707 scopus 로고    scopus 로고
    • IEEE trial-use standard general requirements and test code for oil-immersed HVDC converter transformers
    • IEEE Std C57.129-1999
    • IEEE Std C57.129-1999 IEEE trial-use standard general requirements and test code for oil-immersed HVDC converter transformers[S], 2000.
    • (2000)
  • 20
    • 0036618732 scopus 로고    scopus 로고
    • HVDC test for converter transformer
    • ZHANG Chang-shuan. HVDC test for converter transformer[J].High Voltage Apparatus, 2002, 38(3): 7-9.
    • (2002) High Voltage Apparatus , vol.38 , Issue.3 , pp. 7-9
    • Zhang, C.-S.1
  • 21
    • 78651377961 scopus 로고    scopus 로고
    • Structure and standard and test of HVDC converter transformer
    • HE Yi-yan. Structure and standard and test of HVDC converter transformer[J]. Electrical Equipment, 2006, 7(1): 53-57.
    • (2006) Electrical Equipment , vol.7 , Issue.1 , pp. 53-57
    • He, Y.-Y.1
  • 22
    • 77950553676 scopus 로고    scopus 로고
    • On-site DC voltage withstand test of ±800 kV DC equipment
    • CHEN Zhong, CAI Ze-xiang. On-site DC voltage withstand test of ±800 kV DC equipment[J]. High Voltage Engineering, 2009, 35(10): 2356-2360.
    • (2009) High Voltage Engineering , vol.35 , Issue.10 , pp. 2356-2360
    • Chen, Z.1    Cai, Z.-X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.