-
1
-
-
78751480330
-
Comparison of laser in situ keratomileusis flaps created by 3 femtosecond lasers and a microkeratome
-
Ahn H, Kim JK, Kim CK, et al. Comparison of laser in situ keratomileusis flaps created by 3 femtosecond lasers and a microkeratome. J Cataract Refract Surg. 2011;37(2):349-357.
-
(2011)
J Cataract Refract Surg
, vol.37
, Issue.2
, pp. 349-357
-
-
Ahn, H.1
Kim, J.K.2
Kim, C.K.3
-
2
-
-
79960186551
-
Anterior segment optical coherence tomography measurement of LASIK flaps: Femtosecond laser vs microkeratome
-
Zhou Y, Tian L, Wang N, Dougherty PJ. Anterior segment optical coherence tomography measurement of LASIK flaps: femtosecond laser vs microkeratome. J Refract Surg. 2011;27(6):408-416.
-
(2011)
J Refract Surg
, vol.27
, Issue.6
, pp. 408-416
-
-
Zhou, Y.1
Tian, L.2
Wang, N.3
Dougherty, P.J.4
-
3
-
-
57749175102
-
Corneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment optical coherence tomography
-
von Jagow B, Kohnen T. Corneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment optical coherence tomography. J Cataract Refract Surg. 2009;35(1):35-41.
-
(2009)
J Cataract Refract Surg
, vol.35
, Issue.1
, pp. 35-41
-
-
Von Jagow, B.1
Kohnen, T.2
-
4
-
-
34250615816
-
Anterior segment OCT analysis of thin IntraLase femtosecond flaps
-
Stahl JE, Durrie DS, Schwendeman FJ, Boghossian AJ. Anterior segment OCT analysis of thin IntraLase femtosecond flaps. J Refract Surg. 2007;23(6):555-558. (Pubitemid 46932375)
-
(2007)
Journal of Refractive Surgery
, vol.23
, Issue.6
, pp. 555-558
-
-
Stahl, J.E.1
Durrie, D.S.2
Schwendeman, F.J.3
Boghossian, A.J.4
-
5
-
-
79951937631
-
Reproducibility of LASIK flap thickness using the Zeiss femtosecond laser measured postoperatively by optical coherence tomography
-
Ju WK, Lee JH, Chung TY, Chung ES. Reproducibility of LASIK flap thickness using the Zeiss femtosecond laser measured postoperatively by optical coherence tomography. J Refract Surg. 2011;27(2):106-110.
-
(2011)
J Refract Surg
, vol.27
, Issue.2
, pp. 106-110
-
-
Ju, W.K.1
Lee, J.H.2
Chung, T.Y.3
Chung, E.S.4
-
6
-
-
77954379519
-
A prospective randomized comparison of four femtosecond LASIK flap thicknesses
-
Prakash G, Agarwal A, Yadav A, Jacob S, Kumar DA, Akhtar R. A prospective randomized comparison of four femtosecond LASIK flap thicknesses. J Refract Surg. 2010;26(6):392-402.
-
(2010)
J Refract Surg
, vol.26
, Issue.6
, pp. 392-402
-
-
Prakash, G.1
Agarwal, A.2
Yadav, A.3
Jacob, S.4
Kumar, D.A.5
Akhtar, R.6
-
7
-
-
38349167600
-
Very high-frequency digital ultrasound measurement of the LASIK flap thickness profile using the IntraLase femtosecond laser and M2 and Carriazo-Pendular microkeratomes
-
Alió JL, Piñero DP. Very high-frequency digital ultrasound measurement of the LASIK flap thickness profile using the IntraLase femtosecond laser and M2 and Carriazo-Pendular microkeratomes. J Refract Surg. 2008;24(1):12-23.
-
(2008)
J Refract Surg
, vol.24
, Issue.1
, pp. 12-23
-
-
Alió, J.L.1
Piñero, D.P.2
-
8
-
-
59449105207
-
Thin LASIK flap creation using the SCHWIND Carriazo- Pendular microkeratome
-
Kymionis GD, Portaliou DM, Tsiklis NS, Panagopoulou SI, Pallikaris IG. Thin LASIK flap creation using the SCHWIND Carriazo- Pendular microkeratome. J Refract Surg. 2009;25(1):33-36.
-
(2009)
J Refract Surg
, vol.25
, Issue.1
, pp. 33-36
-
-
Kymionis, G.D.1
Portaliou, D.M.2
Tsiklis, N.S.3
Panagopoulou, S.I.4
Pallikaris, I.G.5
-
9
-
-
79951882107
-
Laser in situ keratomileusis flap measurements: Comparison between observers and between spectral-domain and time-domain anterior segment optical coherence tomography
-
Hall RC, Mohamed FK, Htoon HM, Tan DT, Mehta JS. Laser in situ keratomileusis flap measurements: comparison between observers and between spectral-domain and time-domain anterior segment optical coherence tomography. J Cataract Refract Surg. 2011;37(3):544-551.
-
(2011)
J Cataract Refract Surg
, vol.37
, Issue.3
, pp. 544-551
-
-
Hall, R.C.1
Mohamed, F.K.2
Htoon, H.M.3
Tan, D.T.4
Mehta, J.S.5
-
10
-
-
37349017980
-
Flap thickness reproducibility in laser in situ keratomileusis with a femtosecond laser: Optical coherence tomography measurement
-
DOI 10.1016/j.jcrs.2007.08.036, PII S0886335007017762
-
Kim JH, Lee D, Rhee KI. Flap thickness reproducibility in laser in situ keratomileusis with a femtosecond laser: optical coherence tomography measurement. J Cataract Refract Surg. 2008;34(1):132-136. (Pubitemid 350299780)
-
(2008)
Journal of Cataract and Refractive Surgery
, vol.34
, Issue.1
, pp. 132-136
-
-
Kim, J.-H.1
Lee, D.2
Rhee, K.-I.3
-
11
-
-
56249096888
-
Measurement of LASIK flap thickness with anterior segment optical coherence tomography
-
Cheng AC, Ho T, Lau S, Wong AL, Leung C, Lam DS. Measurement of LASIK flap thickness with anterior segment optical coherence tomography. J Refract Surg. 2008;24(9):879-884.
-
(2008)
J Refract Surg
, vol.24
, Issue.9
, pp. 879-884
-
-
Cheng, A.C.1
Ho, T.2
Lau, S.3
Wong, A.L.4
Leung, C.5
Lam, D.S.6
-
12
-
-
67249126267
-
Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes
-
Prospero Ponce CM, Rocha KM, Smith SD, Krueger RR. Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes. J Cataract Refract Surg. 2009;35(6):1055-1062.
-
(2009)
J Cataract Refract Surg
, vol.35
, Issue.6
, pp. 1055-1062
-
-
Prospero Ponce, C.M.1
Rocha, K.M.2
Smith, S.D.3
Krueger, R.R.4
-
13
-
-
34248590339
-
Comparison of Central Corneal Thickness Measurements by Visante Anterior Segment Optical Coherence Tomography With Ultrasound Pachymetry
-
DOI 10.1016/j.ajo.2007.01.050, PII S0002939407001213
-
Zhao PS, Wong TY, Wong WL, Saw SM, Aung T. Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry. Am J Ophthalmol. 2007;143(6):1047-1049. (Pubitemid 46764644)
-
(2007)
American Journal of Ophthalmology
, vol.143
, Issue.6
, pp. 1047-1049
-
-
Zhao, P.S.1
Wong, T.Y.2
Wong, W.-L.3
Saw, S.-M.4
Aung, T.5
-
14
-
-
70349782492
-
Femtosecond laser versus mechanical microkeratome: A retrospective comparison of visual outcomes at 3 months
-
Tanna M, Schallhorn SC, Hettinger KA. Femtosecond laser versus mechanical microkeratome: a retrospective comparison of visual outcomes at 3 months. J Refract Surg. 2009;25(7 Suppl): S668-S671.
-
(2009)
J Refract Surg
, vol.25
, Issue.7 SUPPL.
-
-
Tanna, M.1
Schallhorn, S.C.2
Hettinger, K.A.3
-
15
-
-
77949398250
-
Accuracy and reproducibility of Artemis central flap thickness and visual outcomes of LASIK with the Carl Zeiss Meditec VisuMax femtosecond laser and MEL 80 excimer laser platforms
-
Reinstein DZ, Archer TJ, Gobbe M, Johnson N. Accuracy and reproducibility of Artemis central flap thickness and visual outcomes of LASIK with the Carl Zeiss Meditec VisuMax femtosecond laser and MEL 80 excimer laser platforms. J Refract Surg. 2010;26(2):107-119.
-
(2010)
J Refract Surg
, vol.26
, Issue.2
, pp. 107-119
-
-
Reinstein, D.Z.1
Archer, T.J.2
Gobbe, M.3
Johnson, N.4
-
16
-
-
41949092968
-
Blade source effect on laser in situ keratomileusis flap thickness with the Amadeus I microkeratome
-
DOI 10.1016/j.jcrs.2007.11.020, PII S0886335007020512
-
Ruth AL, Lynn MJ, Randleman JB, Stulting RD. Blade source effects laser in situ keratomileusis flap thickness with the Amadeus I microkeratome. J Cataract Refract Surg. 2008;34(3):407-410. (Pubitemid 351625585)
-
(2008)
Journal of Cataract and Refractive Surgery
, vol.34
, Issue.3
, pp. 407-410
-
-
Ruth, A.L.1
Lynn, M.J.2
Randleman, J.B.3
Stulting, R.D.4
-
17
-
-
77951831380
-
Influence of flap thickness on visual and refractive outcomes after laser in situ keratomileusis performed with a mechanical keratome
-
Bansal AS, Doherty T, Randleman JB, Stulting RD. Influence of flap thickness on visual and refractive outcomes after laser in situ keratomileusis performed with a mechanical keratome. J Cataract Refract Surg. 2010;36(5):810-813.
-
(2010)
J Cataract Refract Surg
, vol.36
, Issue.5
, pp. 810-813
-
-
Bansal, A.S.1
Doherty, T.2
Randleman, J.B.3
Stulting, R.D.4
-
18
-
-
38349182519
-
Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry
-
Kim HY, Budenz DL, Lee PS, Feuer WJ, Barton K. Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry. Am J Ophthalmol. 2008;145(2):228-232.
-
(2008)
Am J Ophthalmol
, vol.145
, Issue.2
, pp. 228-232
-
-
Kim, H.Y.1
Budenz, D.L.2
Lee, P.S.3
Feuer, W.J.4
Barton, K.5
-
19
-
-
67650397863
-
Comparison of fourier-domain and time-domain optical coherence tomography for assessment of corneal thickness and intersession repeatability
-
Prakash G, Agarwal A, Jacob S, Kumar DA, Banerjee R. Comparison of fourier-domain and time-domain optical coherence tomography for assessment of corneal thickness and intersession repeatability. Am J Ophthalmol. 2009;148(2):282-290.e2.
-
(2009)
Am J Ophthalmol
, vol.148
, Issue.2
-
-
Prakash, G.1
Agarwal, A.2
Jacob, S.3
Kumar, D.A.4
Banerjee, R.5
-
20
-
-
67650432142
-
Comparison of clinically relevant findings from high-speed fourier-domain and conventional time-domain optical coherence tomography
-
Keane PA, Bhatti RA, Brubaker JW, Liakopoulos S, Sadda SR, Walsh AC. Comparison of clinically relevant findings from high-speed fourier-domain and conventional time-domain optical coherence tomography. Am J Ophthalmol. 2009;148(2):242-248.e1.
-
(2009)
Am J Ophthalmol
, vol.148
, Issue.2
-
-
Keane, P.A.1
Bhatti, R.A.2
Brubaker, J.W.3
Liakopoulos, S.4
Sadda, S.R.5
Walsh, A.C.6
-
21
-
-
56549130064
-
Thin-flap (sub-Bowman keratomileusis) versus thick-flap laser in situ keratomileusis for moderate to high myopia: Case-control analysis
-
Azar DT, Ghanem RC, de la Cruz J, et al. Thin-flap (sub-Bowman keratomileusis) versus thick-flap laser in situ keratomileusis for moderate to high myopia: case-control analysis. J Cataract Refract Surg. 2008;34(12):2073-2078.
-
(2008)
J Cataract Refract Surg
, vol.34
, Issue.12
, pp. 2073-2078
-
-
Azar, D.T.1
Ghanem, R.C.2
De La Cruz, J.3
-
22
-
-
24944570935
-
Thin flap laser in situ keratomileusis: Analysis of contrast sensitivity, visual, and refractive outcomes
-
DOI 10.1016/j.jcrs.2004.12.058
-
Cobo-Soriano R, Calvo MA, Beltran J, Llovet FL, Baviera J. Thin flap laser in situ keratomileusis: analysis of contrast sensitivity, visual, and refractive outcomes. J Cataract Refract Surg. 2005;31(7):1357-1365. (Pubitemid 41594447)
-
(2005)
Journal of Cataract and Refractive Surgery
, vol.31
, Issue.7
, pp. 1357-1365
-
-
Cobo-Soriano, R.1
Calvo, M.A.2
Beltran, J.3
Llovet, F.L.4
Baviera, J.5
-
23
-
-
0035192810
-
Effect of acute biomechanical changes on corneal curvature after photokeratectomy
-
Dupps WJ Jr, Roberts C. Effect of acute biomechanical changes on corneal curvature after photokeratectomy. J Refract Surg. 2001;17(6):658-669. (Pubitemid 33098089)
-
(2001)
Journal of Refractive Surgery
, vol.17
, Issue.6
, pp. 658-669
-
-
Dupps Jr., W.J.1
Roberts, C.2
-
24
-
-
56549098155
-
Differences in the corneal biomechanical effects of surface ablation compared with laser in situ keratomileusis using a microkeratome or femtosecond laser
-
Hamilton DR, Johnson RD, Lee N, Bourla N. Differences in the corneal biomechanical effects of surface ablation compared with laser in situ keratomileusis using a microkeratome or femtosecond laser. J Cataract Refract Surg. 2008;34(12):2049-2056.
-
(2008)
J Cataract Refract Surg
, vol.34
, Issue.12
, pp. 2049-2056
-
-
Hamilton, D.R.1
Johnson, R.D.2
Lee, N.3
Bourla, N.4
|