메뉴 건너뛰기




Volumn 197, Issue 5, 2011, Pages

Diagnostic accuracy of pulmonary CT angiography at low tube voltage: Intraindividual comparison of a normal-dose protocol at 120 kVp and a low-dose protocol at 80 kVp using reduced amount of contrast medium in a simulation study

Author keywords

CT; Diagnostic accuracy; Low dose; Pulmonary angiography; Pulmonary embolism; Simulation study

Indexed keywords

AGED; ARTICLE; CLINICAL ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTRAST ENHANCEMENT; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; ELECTRIC POTENTIAL; FEMALE; HUMAN; IMAGE QUALITY; LUNG ANGIOGRAPHY; LUNG EMBOLISM; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; RADIATION DOSE; RADIATION EXPOSURE; RETROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; SIMULATION;

EID: 80054960491     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.11.6750     Document Type: Article
Times cited : (50)

References (21)
  • 1
    • 61449268221 scopus 로고    scopus 로고
    • Minimizing contrast medium doses to diagnose pulmonary embolism with 80-kVp multidetector computed tomography in azotemic patients
    • Holmquist F, Hansson K, Pasquariello F, Bjork J, Nyman U. Minimizing contrast medium doses to diagnose pulmonary embolism with 80-kVp multidetector computed tomography in azotemic patients. Acta Radiol 2009; 50:181-193
    • (2009) Acta Radiol , vol.50 , pp. 181-193
    • Holmquist, F.1    Hansson, K.2    Pasquariello, F.3    Bjork, J.4    Nyman, U.5
  • 2
    • 33645779286 scopus 로고    scopus 로고
    • Eighty-peak kilovoltage 16-channel multidetector computed tomography and reduced contrast-medium doses tailored to body weight to diagnose pulmonary embolism in azotaemic patients
    • Holmquist F, Nyman U. Eighty-peak kilovoltage 16-channel multidetector computed tomography and reduced contrast-medium doses tailored to body weight to diagnose pulmonary embolism in azotaemic patients. Eur Radiol 2006; 16:1165-1176
    • (2006) Eur Radiol , vol.16 , pp. 1165-1176
    • Holmquist, F.1    Nyman, U.2
  • 3
    • 59649088090 scopus 로고    scopus 로고
    • Patient exposure and image quality of low-dose pulmonary computed tomography angiography: Comparison of 100- and 80-kVp protocols
    • Szucs-Farkas Z, Kurmann L, Strautz T, Patak MA, Vock P, Schindera ST. Patient exposure and image quality of low-dose pulmonary computed tomography angiography: comparison of 100- and 80-kVp protocols. Invest Radiol 2008; 43:871-876
    • (2008) Invest Radiol , vol.43 , pp. 871-876
    • Szucs-Farkas, Z.1    Kurmann, L.2    Strautz, T.3    Patak, M.A.4    Vock, P.5    Schindera, S.T.6
  • 4
    • 77952090916 scopus 로고    scopus 로고
    • Ultralow contrast medium doses at CT to diagnose pulmonary embolism in patients with moderate to severe renal impairment: A feasibility study
    • Kristiansson M, Holmquist F, Nyman U. Ultralow contrast medium doses at CT to diagnose pulmonary embolism in patients with moderate to severe renal impairment: a feasibility study. Eur Radiol 2010; 20:1321-1330
    • (2010) Eur Radiol , vol.20 , pp. 1321-1330
    • Kristiansson, M.1    Holmquist, F.2    Nyman, U.3
  • 5
    • 35348977748 scopus 로고    scopus 로고
    • Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: Prospective randomized study
    • DOI 10.1148/radiol.2452061919
    • Heyer CM, Mohr PS, Lemburg SP, Peters SA, Nicolas V. Image quality and radiation exposure at pulmonary CT angiography with 100- or 120- kVp protocol: prospective randomized study. Radiology 2007; 245:577-583 (Pubitemid 47612541)
    • (2007) Radiology , vol.245 , Issue.2 , pp. 577-583
    • Heyer, C.M.1    Mohr, P.S.2    Lemburg, S.P.3    Peters, S.A.4    Nicolas, V.5
  • 6
    • 33846695725 scopus 로고    scopus 로고
    • CT angiography of pulmonary arteries to detect pulmonary embolism: Improvement of vascular enhancement with low kilovoltage settings
    • DOI 10.1148/radiol.2413040128
    • Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, Herold CJ, Prokop M. CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. Radiology 2006; 241: 899-907 (Pubitemid 46190558)
    • (2006) Radiology , vol.241 , Issue.3 , pp. 899-907
    • Schueller-Weidekamm, C.1    Schaefer-Prokop, C.M.2    Weber, M.3    Herold, C.J.4    Prokop, M.5
  • 7
    • 67049110250 scopus 로고    scopus 로고
    • Vascular enhancement and image quality of MDCT pulmonary angiography in 400 cases: Comparison of standard and low kilovoltage settings
    • Matsuoka S, Hunsaker AR, Gill RR, et al. Vascular enhancement and image quality of MDCT pulmonary angiography in 400 cases: comparison of standard and low kilovoltage settings. AJR 2009; 192:1651-1656
    • (2009) AJR , vol.192 , pp. 1651-1656
    • Matsuoka, S.1    Hunsaker, A.R.2    Gill, R.R.3
  • 8
    • 67650790313 scopus 로고    scopus 로고
    • Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80 kVp in 100 patients
    • Szucs-Farkas Z, Strautz T, Patak MA, Kurmann L, Vock P, Schindera ST. Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80 kVp in 100 patients. Eur Radiol 2009; 19:1914-1922
    • (2009) Eur Radiol , vol.19 , pp. 1914-1922
    • Szucs-Farkas, Z.1    Strautz, T.2    Patak, M.A.3    Kurmann, L.4    Vock, P.5    Schindera, S.T.6
  • 9
    • 77749304526 scopus 로고    scopus 로고
    • Using 100- instead of 120-kVp computed tomography to diagnose pulmonary embolism almost halves the radiation dose with preserved diagnostic quality
    • Bjorkdahl P, Nyman U. Using 100- instead of 120-kVp computed tomography to diagnose pulmonary embolism almost halves the radiation dose with preserved diagnostic quality. Acta Radiol 2010; 51:260-270
    • (2010) Acta Radiol , vol.51 , pp. 260-270
    • Bjorkdahl, P.1    Nyman, U.2
  • 10
    • 73349087522 scopus 로고    scopus 로고
    • Detection of pulmonary emboli with CT angiography at reduced radiation exposure and contrast material volume: Comparison of 80 kVp and 120 kVp protocols in a matched cohort
    • Szucs-Farkas Z, Schaller C, Bensler S, Patak MA, Vock P, Schindera ST. Detection of pulmonary emboli with CT angiography at reduced radiation exposure and contrast material volume: comparison of 80 kVp and 120 kVp protocols in a matched cohort. Invest Radiol 2009; 44:793-799
    • (2009) Invest Radiol , vol.44 , pp. 793-799
    • Szucs-Farkas, Z.1    Schaller, C.2    Bensler, S.3    Patak, M.A.4    Vock, P.5    Schindera, S.T.6
  • 11
    • 44449151276 scopus 로고
    • The formation of a radiographic image
    • East Norwalk, CO: Appleton and Lange
    • Wolbarst A. The formation of a radiographic image. In: Physics of radiology. East Norwalk, CO: Appleton and Lange, 1993:147-205
    • (1993) Physics of Radiology , pp. 147-205
    • Wolbarst, A.1
  • 12
    • 34250326683 scopus 로고    scopus 로고
    • The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT
    • DOI 10.1007/s00330-006-0545-2
    • Wessling J, Esseling R, Raupach R, et al. The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT. Eur Radiol 2007; 17:1885-1891 (Pubitemid 46909680)
    • (2007) European Radiology , vol.17 , Issue.7 , pp. 1885-1891
    • Wessling, J.1    Esseling, R.2    Raupach, R.3    Fockenberg, S.4    Osada, N.5    Gerss, J.6    Heindel, W.7    Fischbach, R.8
  • 13
    • 0000209372 scopus 로고
    • Correlated applied anatomy of the bronchial tree and lungs with a system of nomenclature
    • Jackson CL, Huber JF. Correlated applied anatomy of the bronchial tree and lungs with a system of nomenclature. Chest 1943; 9:319-326
    • (1943) Chest , vol.9 , pp. 319-326
    • Jackson, C.L.1    Huber, J.F.2
  • 15
    • 0031010385 scopus 로고    scopus 로고
    • Peripheral pulmonary arteries: Optimization of the spiral CT acquisition protocol
    • Remy-Jardin M, Remy J, Artaud D, Deschildre F, Duhamel A. Peripheral pulmonary arteries: optimization of the spiral CT acquisition protocol. Radiology 1997; 204:157-163 (Pubitemid 27281725)
    • (1997) Radiology , vol.204 , Issue.1 , pp. 157-163
    • Remy-Jardin, M.1    Remy, J.2    Artaud, D.3    Deschildre, F.4    Duhamel, A.5
  • 16
    • 0036068184 scopus 로고    scopus 로고
    • Overview of Prospective Investigation of Pulmonary Embolism Diagnosis II
    • DOI 10.1053/snuc.2002.124177
    • Gottschalk A, Stein PD, Goodman LR, Sostman HD. Overview of Prospective Investigation of Pulmonary Embolism Diagnosis II. Semin Nucl Med 2002; 32:173-182 (Pubitemid 34803590)
    • (2002) Seminars in Nuclear Medicine , vol.32 , Issue.3 , pp. 173-182
    • Gottschalk, A.1    Stein, P.D.2    Goodman, L.R.3    Sostman, H.D.4
  • 17
    • 34548057085 scopus 로고    scopus 로고
    • Discordance between CT and angiography in the PIOPED II study
    • DOI 10.1148/radiol.2443061693
    • Wittram C, Waltman AC, Shepard JA, Halpern E, Goodman LR. Discordance between CT and angiography in the PIOPED II study. Radiology 2007; 244:883-889 (Pubitemid 47292101)
    • (2007) Radiology , vol.244 , Issue.3 , pp. 883-889
    • Wittram, C.1    Waltman, A.C.2    Shepard, J.-A.O.3    Halpern, E.4    Goodman, L.R.5
  • 19
    • 67650075304 scopus 로고    scopus 로고
    • Pulmonary embolism detection with dual-energy CT: Experimental study of dual-source CT in rabbits
    • Zhang LJ, Zhao YE, Wu SY, et al. Pulmonary embolism detection with dual-energy CT: experimental study of dual-source CT in rabbits. Radiology 2009; 252:61-70
    • (2009) Radiology , vol.252 , pp. 61-70
    • Zhang, L.J.1    Zhao, Y.E.2    Wu, S.Y.3
  • 20
    • 14644433627 scopus 로고    scopus 로고
    • Diagnosis of subsegmental pulmonary emboli: A multi-center study using a porcine model
    • DOI 10.1097/01.rti.0000155044.82156.ad
    • Coxson HO, Baile EM, King GG, Mayo JR. Diagnosis of subsegmental pulmonary emboli: a multi-center study using a porcine model. J Thorac Imaging 2005; 20:24-31 (Pubitemid 40316563)
    • (2005) Journal of Thoracic Imaging , vol.20 , Issue.1 , pp. 24-31
    • Coxson, H.O.1    Baile, E.M.2    King, G.G.3    Mayo, J.R.4
  • 21
    • 0035113744 scopus 로고    scopus 로고
    • Diagnostik der akuten lungenembolie mittels spiral-CT und 3D-rekonstruktion: Entwicklung eines Tiermodells und technischer Probekorper im Ex-vivo-Experiment
    • DOI 10.1007/s001170050962
    • Ries BG, Kauczor HU, Konerding MA, Thelen M. Diagnosis of acute lung embolism with spiral CT and 3D reconstruction: development of an animal model and technical probe in an ex-vivo experiment (in German). Radiologe 2001; 41:187-194 (Pubitemid 32172286)
    • (2001) Radiologe , vol.41 , Issue.2 , pp. 187-194
    • Ries, B.G.1    Kauczor, H.-U.2    Konerding, M.A.3    Thelen, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.