메뉴 건너뛰기




Volumn 16, Issue 3, 2011, Pages 156-160

PICC Zone Insertion Method™ (ZIM™): A systematic approach to determine the ideal insertion site for PICCs in the upper arm

(1)  Dawson, Robert B a  

a NONE

Author keywords

[No Author keywords available]

Indexed keywords

BLEEDING; BLOOD FLOW; CARDIOVASCULAR RISK; CATHETER INFECTION; CLINICAL EFFECTIVENESS; DEEP VEIN THROMBOSIS; ECCHYMOSIS; HUMAN; LUNG EMBOLISM; OUTCOME ASSESSMENT; PATIENT SAFETY; PERIPHERALLY INSERTED CENTRAL VENOUS CATHETER; POSTTHROMBOSIS SYNDROME; REVIEW; ULTRASOUND; VASCULAR ACCESS; VEIN DIAMETER;

EID: 80054934650     PISSN: 15528855     EISSN: 15571289     Source Type: Journal    
DOI: 10.2309/java.16-3-5     Document Type: Article
Times cited : (102)

References (21)
  • 1
    • 68649088117 scopus 로고    scopus 로고
    • The Joint Commission Joint Commission Resources website. Updated 2008. Accessed June 2010.
    • The Joint Commission. Patient safety solutions. Joint Commission Resources website. http://www.ccforpatientsafety.org/Patient-Safety-Solutions/. Updated 2008. Accessed June 2010.
    • Patient Safety Solutions
  • 2
    • 0141719807 scopus 로고    scopus 로고
    • Upper extremity deep vein thrombosis
    • Shah MK, Burke DT, Shah SH. Upper extremity deep vein thrombosis. South Med J. 2003;96(7):669-672.
    • (2003) South Med J , vol.96 , Issue.7 , pp. 669-672
    • Shah, M.K.1    Burke, D.T.2    Shah, S.H.3
  • 3
    • 53449086248 scopus 로고    scopus 로고
    • Central venous catheter-related thrombosis
    • Yacopetti N. Central venous catheter-related thrombosis. J Infus Nurs. 2008;31(4):241-248.
    • (2008) J Infus Nurs , vol.31 , Issue.4 , pp. 241-248
    • Yacopetti, N.1
  • 6
    • 70449724751 scopus 로고    scopus 로고
    • Risk of venous thromboembolism in hospitalized patients with peripherally inserted central catheters
    • Lobo BL, Vaidean G, Broyles J, Reaves AB, Shorr RL. Risk of venous thromboembolism in hospitalized patients with peripherally inserted central catheters. J Hosp Med. 2009;4(7):417-422.
    • (2009) J Hosp Med , vol.4 , Issue.7 , pp. 417-422
    • Lobo, B.L.1    Vaidean, G.2    Broyles, J.3    Reaves, A.B.4    Shorr, R.L.5
  • 8
    • 70349245332 scopus 로고    scopus 로고
    • The use of ultrasound to improve practice and reduce complication rates in peripherally inserted central catheter insertions
    • Stokowski G, Steele D, Wilson D. The use of ultrasound to improve practice and reduce complication rates in peripherally inserted central catheter insertions. J Infus Nurs. 2009;32(3): 145-154.
    • (2009) J Infus Nurs , vol.32 , Issue.3 , pp. 145-154
    • Stokowski, G.1    Steele, D.2    Wilson, D.3
  • 9
    • 33644640050 scopus 로고    scopus 로고
    • Guidelines for the prevention of intravascular catheter-related infections: Recommendations relevant to interventional radiology
    • Miller DL, O'Grady NP. Guidelines for the prevention of intravascular catheter-related infections: recommendations relevant to interventional radiology. J Vasc Interv Radiol. 2003;14:S355-S358.
    • (2003) J Vasc Interv Radiol , vol.14
    • Miller, D.L.1    O'Grady, N.P.2
  • 10
    • 67649641995 scopus 로고    scopus 로고
    • Going around in circles is this the best practice for preparing the skin?
    • Stonecypher K. Going around in circles is this the best practice for preparing the skin? Crit Care Nurs Q. 2009;32(2):94-98.
    • (2009) Crit Care Nurs Q , vol.32 , Issue.2 , pp. 94-98
    • Stonecypher, K.1
  • 11
    • 42249085756 scopus 로고    scopus 로고
    • Nursing beyond the "process": Collegiality and consultation improves outcomes by protecting the tissue integrity of PICC insertion sites
    • DOI 10.2309/java.13-1-3
    • Dawson RB. Nursing beyond the "Process": collegiality and consultation improves outcomes by protecting the tissue integrity of PICC insertion sites. JAVA. 2008;13(1):8-11. (Pubitemid 351545991)
    • (2008) JAVA - Journal of the Association for Vascular Access , vol.13 , Issue.1 , pp. 8-11
    • Dawson, R.B.1
  • 12
    • 48549107616 scopus 로고    scopus 로고
    • Peripheral IVs: Factors affecting complications and patency-a randomized controlled trial
    • Tripathi S, Kaushik V, Singh V. Peripheral IVs: factors affecting complications and patency-a randomized controlled trial. J Infus Nurs. 2008;31(3):182-188.
    • (2008) J Infus Nurs , vol.31 , Issue.3 , pp. 182-188
    • Tripathi, S.1    Kaushik, V.2    Singh, V.3
  • 13
    • 80054912126 scopus 로고    scopus 로고
    • Mitigating the risks with zone defense
    • Bierman S. Mitigating the risks with zone defense. Managing Infection Control. 2003;37-41.
    • (2003) Managing Infection Control , pp. 37-41
    • Bierman, S.1
  • 14
    • 48549092625 scopus 로고    scopus 로고
    • Complications and controversies associated with peripherally inserted central catheters
    • Hertzog DR, Waybill PN. Complications and controversies associated with peripherally inserted central catheters. J Infus Nurs.2008;31(3):159-163.
    • (2008) J Infus Nurs , vol.31 , Issue.3 , pp. 159-163
    • Hertzog, D.R.1    Waybill, P.N.2
  • 16
    • 80054885824 scopus 로고    scopus 로고
    • The eMedicine Clinical Knowledge Base website. Updated January 16, 2009. Accessed March 18, 2011
    • Patel K, Feied CF. Deep vein thrombosis [Vascular Surgery - Medical Topics]. The eMedicine Clinical Knowledge Base website. http://phstw1p1. partners.org:2217/printtopic.asp?bookid=6&topic=2785 Updated January 16, 2009. Accessed March 18, 2011.
    • Deep Vein Thrombosis [Vascular Surgery - Medical Topics]
    • Patel, K.1    Feied, C.F.2
  • 17
    • 4544329929 scopus 로고    scopus 로고
    • Venous thrombosis: On the history of Virchow's triad
    • Dickson BC. Venous thrombosis: on the history of Virchow's triad. Univ Tor Med J .2004;81(3):166-171.
    • (2004) Univ Tor Med J , vol.81 , Issue.3 , pp. 166-171
    • Dickson, B.C.1
  • 18
    • 48549097376 scopus 로고    scopus 로고
    • The efficacy of upper arm placement of peripherally inserted central catheters using bedside ultrasound and microintroducer technique
    • Nichols I, Humphrey JP. The efficacy of upper arm placement of peripherally inserted central catheters using bedside ultrasound and microintroducer technique. J Infus Nurs. 2008;31(3):165-176.
    • (2008) J Infus Nurs , vol.31 , Issue.3 , pp. 165-176
    • Nichols, I.1    Humphrey, J.P.2
  • 19
    • 80054922294 scopus 로고    scopus 로고
    • website. Updated 2010. Accessed March 18, 2011
    • Nave CR. Poiseuille's law [Hyperphysics, Newtonian Fluids]. Department of Physics and Astronomy, Georgia State University website. http://hyperphysics. phy-astr.gsu.edu/hbase/pturb.html#aor. Updated 2010. Accessed March 18, 2011.
    • Poiseuille's Law [Hyperphysics, Newtonian Fluids]
    • Nave, C.R.1
  • 20
    • 79960398837 scopus 로고    scopus 로고
    • The effect of catheter to vein ratio on blood flow rates in a simulated model of peripherally inserted central venous catheters
    • Nifong TP, McDevitt TJ. The effect of catheter to vein ratio on blood flow rates in a simulated model of peripherally inserted central venous catheters. Chest. 2011;140(1):48-53.
    • (2011) Chest , vol.140 , Issue.1 , pp. 48-53
    • Nifong, T.P.1    McDevitt, T.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.