메뉴 건너뛰기




Volumn 3, Issue 20, 2011, Pages 2335-2347

The effect of hematocrit and punch location on assay bias during quantitative bioanalysis of dried blood spot samples

Author keywords

[No Author keywords available]

Indexed keywords

ACETONITRILE; CHEMICAL COMPOUND; GSK1; GSK2; GSK3; GSK4; METHANOL; PARACETAMOL; TRIFLUOROACETIC ACID; UNCLASSIFIED DRUG; WATER;

EID: 80054875851     PISSN: 17576180     EISSN: 17576199     Source Type: Journal    
DOI: 10.4155/bio.11.220     Document Type: Article
Times cited : (141)

References (19)
  • 1
    • 75449123150 scopus 로고
    • A simple phenylalanine method for detecting phenylketonuria in large populations of newborn infants
    • Guthrie R, Suzi A. A simple phenylalanine method for detecting phenylketonuria in large populations of newborn infants. Pediatrics 32, 338-343 (1963).
    • (1963) Pediatrics , vol.32 , pp. 338-343
    • Guthrie, R.1    Suzi, A.2
  • 2
    • 0028130264 scopus 로고
    • Detection of human immunodeficiency virus type 1 (HIV-1) in heel prick blood on filter paper from children born to HIV-seropositive mothers
    • Nyambi PN, Fransen K, De Beenhouwer H et al. Detection of human immunodeficiency virus type 1 (HIV-1) in heel prick blood on filter paper from children born to HIV-seropositive mothers. J. Clin. Microbiol. 32, 2858-2860 (1994).
    • (1963) J. Clin. Microbiol. , vol.32 , pp. 2858-2860
    • Nyambi, P.N.1    Fransen, K.2    De Beenhouwer, H.3
  • 3
    • 67651121813 scopus 로고    scopus 로고
    • Dried blood spot methods in therapeutic drug monitoring: Methods, assays and pitfalls
    • Edelbroek PM, van der Heijden J, Stolk LM. Dried blood spot methods in therapeutic drug monitoring: methods, assays and pitfalls. Ther. Drug Monit. 31, 327-336 (2009).
    • (2009) Ther. Drug Monit. , vol.31 , pp. 327-336
    • Edelbroek, P.M.1    Van Der Heijden, J.2    Stolk, L.M.3
  • 4
    • 75149186915 scopus 로고    scopus 로고
    • Dried blood spot sampling in combination with LC-MS/MS for quantitative analysis of small molecules
    • Li W, Tse FL. Dried blood spot sampling in combination with LC-MS/MS for quantitative analysis of small molecules. Biomed. Chromatogr. 24, 49-65 (2010).
    • (2010) Biomed. Chromatogr. , vol.24 , pp. 49-65
    • Li, W.1    Tse, F.L.2
  • 5
    • 79953137816 scopus 로고    scopus 로고
    • Application of the DBS methodology to a toxicokinetic study in rats and transferability of analysis between bioanalytical laboratories
    • Turpin PE, Burnette JE, Goodwin L et al. Application of the DBS methodology to a toxicokinetic study in rats and transferability of analysis between bioanalytical laboratories. Bioanalysis 2(8), 1489-1499 (2010).
    • (2010) Bioanalysis , vol.2 , Issue.8 , pp. 1489-1499
    • Turpin, P.E.1    Burnette, J.E.2    Goodwin, L.3
  • 6
    • 79951731157 scopus 로고    scopus 로고
    • Glowing future for dried blood spot sampling
    • Spooner NA. Glowing future for dried blood spot sampling. Bioanalysis 2(8), 1343-1344 (2010).
    • (2010) Bioanalysis , vol.2 , Issue.8 , pp. 1343-1344
    • Spooner, N.A.1
  • 7
    • 0035016950 scopus 로고    scopus 로고
    • Use of filter paper for the collection and analysis of human whole blood specimens
    • Mei JV, Alexander JR, Adam BW et al. Use of filter paper for the collection and analysis of human whole blood specimens. J. Nutr. 131(5), S1631-S1636 (2001).
    • (2001) J. Nutr. , vol.131 , Issue.5
    • Mei, J.V.1    Alexander, J.R.2    Adam, B.W.3
  • 8
    • 0003484310 scopus 로고    scopus 로고
    • US FDA Department of Health and Human Services, Center for Drug Evaluation and Research,Rockville MD, USA
    • US FDA, Department of Health and Human Services, Center for Drug Evaluation and Research. Guidance for Industry: Bioanalytical Method Validation. Rockville, MD, USA (2001).
    • (2001) Guidance for Industry: Bioanalytical Method Validation
  • 9
    • 78049332396 scopus 로고    scopus 로고
    • European Medicines Agency, EMEA/CHMP/EWP/192217/2009
    • US FDA, Department of Health and Human Services, Center for Drug Evaluation and Research. Guidance for Industry: Bioanalytical Method Validation. Rockville, MD, USA (2001). 9 European Medicines Agency. Draft guideline on validation of bioanalytical methods. EMEA/CHMP/EWP/192217/2009 (2009).
    • (2009) Draft Guideline on Validation of Bioanalytical Methods
  • 10
    • 0029118956 scopus 로고
    • Evaluation of factors influencing precision in the analysis of samples taken from blood spots on filter paper
    • O'Broin SD, Kelleher BP, Gunter E. Evaluation of factors influencing precision in the analysis of samples taken from blood spots on filter paper. Clin. Lab. Haem. 17, 185-188 (1995).
    • (1995) Clin. Lab. Haem. , vol.17 , pp. 185-188
    • O'Broin, S.D.1    Kelleher, B.P.2    Gunter, E.3
  • 11
    • 33747877255 scopus 로고    scopus 로고
    • Influence of hematocrit and localisation of punch in dried blood spots on levels of amino acids and acylcarnitines measured by tandem mass spectrometry
    • DOI 10.1016/j.cca.2006.04.013, PII S0009898106002397
    • Holub M, Tuschl K, Ratschmann R et al. Influence of hematocrit and localisation of punch in dried blood spots on levels of amino acids and acylcarnitines measured by tandem mass spectrometry. Clin. Chem. Acta. 373, 27-31 (2006). (Pubitemid 44292169)
    • (2006) Clinica Chimica Acta , vol.373 , Issue.1-2 , pp. 27-31
    • Holub, M.1    Tuschl, K.2    Ratschmann, R.3    Strnadova, K.A.4    Muhl, A.5    Heinze, G.6    Sperl, W.7    Bodamer, O.A.8
  • 12
    • 79953133315 scopus 로고    scopus 로고
    • Impact of various factors on radioactivity distribution in different DBS papers
    • Ren X, Paehler T, Zimmer M et al. Impact of various factors on radioactivity distribution in different DBS papers. Bioanalysis. 2(8), 1469-1475 (2010).
    • (2010) Bioanalysis. , vol.2 , Issue.8 , pp. 1469-1475
    • Ren, X.1    Paehler, T.2    Zimmer, M.3
  • 13
    • 58549113559 scopus 로고    scopus 로고
    • Increased perimeter red cell concentration in filter paper blood spot samples is consistent with constant-load size exclusion chromatography occurring during application
    • Stickle DF, Rawlinson NJ, Landmark JD. Increased perimeter red cell concentration in filter paper blood spot samples is consistent with constant-load size exclusion chromatography occurring during application. Clin. Chim. Acta. 401(1-2), 42-45 (2009).
    • (2009) Clin. Chim. Acta. , vol.401 , Issue.1-2 , pp. 42-45
    • Stickle, D.F.1    Rawlinson, N.J.2    Landmark, J.D.3
  • 15
    • 58249136113 scopus 로고    scopus 로고
    • Reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period: Data from a multihospital health care system
    • Jopling J, Henry E, Wiedmeier SE et al. Reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period: data from a multihospital health care system. Pediatrics 123, e333-e337 (2009).
    • (2009) Pediatrics , vol.123
    • Jopling, J.1    Henry, E.2    Wiedmeier, S.E.3
  • 16
    • 3242707057 scopus 로고    scopus 로고
    • Differential diagnosis and management of polycythemia
    • DOI 10.1016/j.pcl.2004.03.012
    • Pappas A, Delaney-Black V. Differential diagnosis and management of polycythemia. Pediatr. Clin. N. Am. 51, 1063-1086 (2004). (Pubitemid 38962684)
    • (2004) Pediatric Clinics of North America , vol.51 , Issue.4 , pp. 1063-1086
    • Pappas, A.1    Delaney-Black, V.2
  • 17
    • 79953137467 scopus 로고    scopus 로고
    • The effect of hematocrit on assay bias when using DBS samples for the quantitative bioanalysis of drugs
    • Denniff P. Spooner N. The effect of hematocrit on assay bias when using DBS samples for the quantitative bioanalysis of drugs. Bioanalysis. 2(8), 1385-1395 (2010).
    • (2010) Bioanalysis. , vol.2 , Issue.8 , pp. 1385-1395
    • Denniff, P.1    Spooner, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.