메뉴 건너뛰기




Volumn 52, Issue 9, 2011, Pages 6934-6939

Identification of Schlemm's Canal and Its Surrounding Tissues by Anterior Segment Fourier Domain Optical Coherence Tomography

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANTERIOR EYE CHAMBER; ANTERIOR EYE CHAMBER ANGLE; ARTICLE; B SCAN; COMPARATIVE STUDY; DESCEMET MEMBRANE; FOURIER DOMAIN OPTICAL COHERENCE TOMOGRAPHY; HUMAN; HUMAN TISSUE; INTRAOCULAR PRESSURE; MALE; NORMAL HUMAN; OPTICAL COHERENCE TOMOGRAPHY; PRIORITY JOURNAL; REPRODUCIBILITY; SCHLEMM CANAL; TRABECULAR MESHWORK; VISCOCANALOSTOMY; CORNEA LIMBUS; ENUCLEATION; FOURIER ANALYSIS; HISTOLOGY; METHODOLOGY; MIDDLE AGED; PHYSIOLOGY; SCLERA; VISUAL ACUITY;

EID: 80054869551     PISSN: 01460404     EISSN: 15525783     Source Type: Journal    
DOI: 10.1167/iovs.10-7009     Document Type: Article
Times cited : (69)

References (23)
  • 1
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science. 1991;254:1178-1181.
    • (1991) Science. , vol.254 , pp. 1178-1181
    • Huang, D.1    Swanson, E.A.2    Lin, C.P.3
  • 2
    • 35748971818 scopus 로고    scopus 로고
    • Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    • Li H, Leung CK, Cheung CY, et al. Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography. Br J Ophthalmol. 2007;91:1490-1492.
    • (2007) Br J Ophthalmol. , vol.91 , pp. 1490-1492
    • Li, H.1    Leung, C.K.2    Cheung, C.Y.3
  • 3
    • 42649140555 scopus 로고    scopus 로고
    • Comparative study of central corneal thickness measurement with slit-lamp optical coherence tomography and Visante optical coherence tomography
    • Li H, Leung CK, Cheung CY, et al. Comparative study of central corneal thickness measurement with slit-lamp optical coherence tomography and Visante optical coherence tomography. Ophthalmology. 2008;115:796-801.
    • (2008) Ophthalmology. , vol.115 , pp. 796-801
    • Li, H.1    Leung, C.K.2    Cheung, C.Y.3
  • 4
    • 0038618462 scopus 로고    scopus 로고
    • Performance of Fourier domain vs. time domain optical coherence tomography
    • Leitgeb R, Hitzenberger C, Fercher A. Performance of Fourier domain vs. time domain optical coherence tomography. Opt Express. 2003;11 889-894.
    • (2003) Opt Express. , vol.11 , pp. 889-894
    • Leitgeb, R.1    Hitzenberger, C.2    Fercher, A.3
  • 5
    • 63649129753 scopus 로고    scopus 로고
    • Clinical and research applications of anterior segment optical coherence tomography
    • Ramos JLB, Li Y, Huang D. Clinical and research applications of anterior segment optical coherence tomography. Clin Exp Ophthalmol. 2009;37:81-89.
    • (2009) Clin Exp Ophthalmol. , vol.37 , pp. 81-89
    • Ramos, J.L.B.1    Li, Y.2    Huang, D.3
  • 6
    • 34648834873 scopus 로고    scopus 로고
    • Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography
    • Radhakrishnan S, See J, Smith SD, et al. Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography. Invest Ophthalmol Vis Sci. 2007;48: 3683-3688.
    • (2007) Invest Ophthalmol Vis Sci. , vol.48 , pp. 3683-3688
    • Radhakrishnan, S.1    See, J.2    Smith, S.D.3
  • 7
    • 42649119772 scopus 로고    scopus 로고
    • Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle
    • Sakata LM, Lavanya R, Friedman DS, et al. Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle. Ophthalmology. 2008;115:769-774.
    • (2008) Ophthalmology. , vol.115 , pp. 769-774
    • Sakata, L.M.1    Lavanya, R.2    Friedman, D.S.3
  • 8
    • 33646143320 scopus 로고    scopus 로고
    • Corneal pachymetry mapping with high-speed optical coherence tomography
    • Li Y, Shekhar R, Huang D. Corneal pachymetry mapping with high-speed optical coherence tomography. Ophthalmology. 2006; 113:792-799.
    • (2006) Ophthalmology. , vol.113 , pp. 792-799
    • Li, Y.1    Shekhar, R.2    Huang, D.3
  • 9
    • 34248590339 scopus 로고    scopus 로고
    • Comparison of central corneal thickness measurements by Visante anterior segment optical coherence tomography with ultrasound pachymetry
    • Zhao PS, Wong TY, Wong WL, et al. Comparison of central corneal thickness measurements by Visante anterior segment optical coherence tomography with ultrasound pachymetry. Am J Ophthalmol. 2007;143:1047-1049.
    • (2007) Am J Ophthalmol. , vol.143 , pp. 1047-1049
    • Zhao, P.S.1    Wong, T.Y.2    Wong, W.L.3
  • 10
    • 65349131841 scopus 로고    scopus 로고
    • Anterior segment biometry using 3-dimensional optic coherence tomography
    • Fukuda S, Kawana K, Yasuno Y, Oshika T. Anterior segment biometry using 3-dimensional optic coherence tomography. Ophthalmology. 2009;116:882-889.
    • (2009) Ophthalmology. , vol.116 , pp. 882-889
    • Fukuda, S.1    Kawana, K.2    Yasuno, Y.3    Oshika, T.4
  • 11
    • 33845750623 scopus 로고    scopus 로고
    • Imaging of trabeculectomy blebs using anterior segment optical coherence tomography
    • Singh M, Chew PT, Friedman DS, et al. Imaging of trabeculectomy blebs using anterior segment optical coherence tomography. Ophthalmology. 2007;114:47-53.
    • (2007) Ophthalmology. , vol.114 , pp. 47-53
    • Singh, M.1    Chew, P.T.2    Friedman, D.S.3
  • 12
    • 42149126974 scopus 로고    scopus 로고
    • Three dimensional anterior segment optical coherence tomography of filtering blebs after trabeculectomy
    • Miura M, Kawana K, Iwasaki T, et al. Three dimensional anterior segment optical coherence tomography of filtering blebs after trabeculectomy. J Glaucoma. 2008;17:308-317.
    • (2008) J Glaucoma. , vol.17 , pp. 308-317
    • Miura, M.1    Kawana, K.2    Iwasaki, T.3
  • 13
    • 67349220412 scopus 로고    scopus 로고
    • Evaluation of trabeculectomy blebs using 3-dimensional cornea and anterior segment optical coherence tomography
    • Kawana K, Kiuchi T, Yasuno Y, Oshika T. Evaluation of trabeculectomy blebs using 3-dimensional cornea and anterior segment optical coherence tomography. Ophthalmology. 2009;116:848-855.
    • (2009) Ophthalmology. , vol.116 , pp. 848-855
    • Kawana, K.1    Kiuchi, T.2    Yasuno, Y.3    Oshika, T.4
  • 14
    • 25844457745 scopus 로고    scopus 로고
    • The Tajimi study report 2: Prevalence of primary angle closure and secondary glaucoma in a Japanese population
    • Yamamoto T, Iwase A, Araie M, et al. The Tajimi study report 2: prevalence of primary angle closure and secondary glaucoma in a Japanese population. Ophthalmology. 2005;112:1661-1669.
    • (2005) Ophthalmology. , vol.112 , pp. 1661-1669
    • Yamamoto, T.1    Iwase, A.2    Araie, M.3
  • 15
    • 53149121028 scopus 로고    scopus 로고
    • The prevalence and types of glaucoma in Malay people: The Singapore Malay eye study
    • Shen SY, Wong TY, Foster PJ, et al. The prevalence and types of glaucoma in Malay people: the Singapore Malay eye study. Invest Ophthalmol Vis Sci. 2008;49:3846-3851.
    • (2008) Invest Ophthalmol Vis Sci. , vol.49 , pp. 3846-3851
    • Shen, S.Y.1    Wong, T.Y.2    Foster, P.J.3
  • 16
    • 33644655886 scopus 로고    scopus 로고
    • The number of people with glaucoma world wide in 2010 and 2020
    • Quigley HA, Broman AT. The number of people with glaucoma world wide in 2010 and 2020. Br J Ophthalmol. 2006;90:262-267.
    • (2006) Br J Ophthalmol. , vol.90 , pp. 262-267
    • Quigley, H.A.1    Broman, A.T.2
  • 17
    • 67949104885 scopus 로고    scopus 로고
    • Prevalence and determinants of angle closure in central Sri Lanka: The Kandy Eye Study
    • Casson RJ, Baker M, Edussuriya K, et al. Prevalence and determinants of angle closure in central Sri Lanka: the Kandy Eye Study. Ophthalmology. 2009;116:1444-1449.
    • (2009) Ophthalmology. , vol.116 , pp. 1444-1449
    • Casson, R.J.1    Baker, M.2    Edussuriya, K.3
  • 18
    • 13244292232 scopus 로고    scopus 로고
    • Intraoperative 2-dimensional optical coherence tomography as a new tool for anterior segment surgery
    • Geering G, Muller M, Winter C, et al. Intraoperative 2-dimensional optical coherence tomography as a new tool for anterior segment surgery. Arch Ophthalmol. 2005;123:253-257.
    • (2005) Arch Ophthalmol. , vol.123 , pp. 253-257
    • Geering, G.1    Muller, M.2    Winter, C.3
  • 19
    • 45149119148 scopus 로고    scopus 로고
    • Detailed visualization of the anterior segment using Fourier-domain optical coherence tomography
    • Asrani S, Sarunic M, Santiago C, Izatt J. Detailed visualization of the anterior segment using Fourier-domain optical coherence tomography. Arch Ophthalmol. 2008;126:765-771.
    • (2008) Arch Ophthalmol. , vol.126 , pp. 765-771
    • Asrani, S.1    Sarunic, M.2    Santiago, C.3    Izatt, J.4
  • 21
    • 77955904669 scopus 로고    scopus 로고
    • Identification and assessment of Schlemm's canal by spectral domain optical coherence tomography
    • Kagemann L, Wollstein G, Ishikawa H, et al. Identification and assessment of Schlemm's canal by spectral domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2010;51:4054-4059.
    • (2010) Invest Ophthalmol Vis Sci. , vol.51 , pp. 4054-4059
    • Kagemann, L.1    Wollstein, G.2    Ishikawa, H.3
  • 22
    • 0029867061 scopus 로고    scopus 로고
    • Schlemm's canal and primary open angle glaucoma: Correlation between Schlemm's canal dimensions and outflow facility
    • Allingham RR, de Kater AW, Ethier CR. Schlemm's canal and primary open angle glaucoma: correlation between Schlemm's canal dimensions and outflow facility. Exp Eye Res. 1996;62:101-109.
    • (1996) Exp Eye Res. , vol.62 , pp. 101-109
    • Allingham, R.R.1    de Kater, A.W.2    Ethier, C.R.3
  • 23
    • 62449261172 scopus 로고    scopus 로고
    • High-definition optical coherence tomography imaging of the iridocorneal angle of the eye
    • Wong HT, Lim MC, Sakata LM, et al. High-definition optical coherence tomography imaging of the iridocorneal angle of the eye. Arch Ophthalmol. 2009;127:256-260.
    • (2009) Arch Ophthalmol. , vol.127 , pp. 256-260
    • Wong, H.T.1    Lim, M.C.2    Sakata, L.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.