메뉴 건너뛰기




Volumn 17, Issue 6, 2011, Pages 29-36

Motor and generator windings

Author keywords

[No Author keywords available]

Indexed keywords

COMMODITY PRODUCTS; END USERS; ENGINEERING FIRMS; MANUFACTURING COST; ON-MACHINES; STATISTICAL DATAS; STATOR WINDING;

EID: 80054699493     PISSN: 10772618     EISSN: None     Source Type: Journal    
DOI: 10.1109/MIAS.2011.942303     Document Type: Article
Times cited : (10)

References (12)
  • 1
    • 0342668461 scopus 로고    scopus 로고
    • Utilizing reduced build concepts in the development of insulation systems for large motors
    • Cincinnati, OH, Oct
    • B. J. Moore, R. H. Rehder, and R. E. Draper, "Utilizing reduced build concepts in the development of insulation systems for large motors," in Proc. IEEE Electrical Insulation Conf., Cincinnati, OH, Oct. 1999, pp. 347-352.
    • (1999) Proc. IEEE Electrical Insulation Conf. , pp. 347-352
    • Moore, B.J.1    Rehder, R.H.2    Draper, R.E.3
  • 2
    • 6344270227 scopus 로고    scopus 로고
    • Design and manufacture of energy efficient and environmentally friendly large machines
    • Sept
    • N. Glew, "Design and manufacture of energy efficient and environmentally friendly large machines," in Proc. IEE Power Division Colloquium 99/178, Sept. 1999.
    • (1999) Proc. IEE Power Division Colloquium 99/178
    • Glew, N.1
  • 3
    • 17644382313 scopus 로고    scopus 로고
    • Effects of converter pulses on the electrical insulation in low and medium voltage motors
    • Mar
    • J. G. Wheeler, "Effects of converter pulses on the electrical insulation in low and medium voltage motors," IEEE Electr. Insul. Mag., vol. 21, no. 2, pp. 22-29, Mar. 2005.
    • (2005) IEEE Electr. Insul. Mag. , vol.21 , Issue.2 , pp. 22-29
    • Wheeler, J.G.1
  • 4
    • 68249157021 scopus 로고    scopus 로고
    • Stator insulation system evaluation and improvement for MV adjustable speed drive application
    • Cincinnati, OH, Sept
    • W. Chen, G. Gao, and C. A. Mouton, "Stator insulation system evaluation and improvement for MV adjustable speed drive application," in Proc. IEEE PCIC, Cincinnati, OH, Sept. 2008, pp. 241-246.
    • (2008) Proc. IEEE PCIC , pp. 241-246
    • Chen, W.1    Gao, G.2    Mouton, C.A.3
  • 5
    • 14844330714 scopus 로고    scopus 로고
    • Root cause diagnostics of generator service failures
    • Sept
    • C. V. Maughan, "Root cause diagnostics of generator service failures," in Proc. IEEE Int. Symp. Electrical Insulation, Sept. 2004, pp. 154-159.
    • (2004) Proc. IEEE Int. Symp. Electrical Insulation , pp. 154-159
    • Maughan, C.V.1
  • 6
    • 0026886680 scopus 로고
    • Cause and analysis of stator and rotor failures in three phase squirrel cage induction motors
    • July/Aug
    • A. H. Bonnet and G. C. Soukup, "Cause and analysis of stator and rotor failures in three phase squirrel cage induction motors," IEEE Trans Ind. Applicat., vol. 28, no. 4, pp. 921-937, July/Aug. 1992.
    • (1992) IEEE Trans Ind. Applicat. , vol.28 , Issue.4 , pp. 921-937
    • Bonnet, A.H.1    Soukup, G.C.2
  • 7
    • 5044246962 scopus 로고    scopus 로고
    • Effect of manufacturer, winding age and insulation type on stator winding PD levels
    • Sept
    • G. C. Stone and V. Warren, "Effect of manufacturer, winding age and insulation type on stator winding PD levels," IEEE Electr. Insul. Mag., vol. 20, no. 5, pp. 13-17, Sept. 2004.
    • (2004) IEEE Electr. Insul. Mag. , vol.20 , Issue.5 , pp. 13-17
    • Stone, G.C.1    Warren, V.2
  • 9
    • 49449101304 scopus 로고    scopus 로고
    • Design dependent slot discharge and vibration sparking on high voltage windings
    • Aug
    • M. Liese and M. Brown, "Design dependent slot discharge and vibration sparking on high voltage windings," IEEE Trans Dielect. Elect. Insulation, vol. 15, no. 4, pp. 927-932, Aug. 2008.
    • (2008) IEEE Trans Dielect. Elect. Insulation , vol.15 , Issue.4 , pp. 927-932
    • Liese, M.1    Brown, M.2
  • 10
    • 33846239017 scopus 로고    scopus 로고
    • A suggested approach for specifying PD testing as a new winding acceptance test
    • Oct
    • G. C. Stone, "A suggested approach for specifying PD testing as a new winding acceptance test," in Proc. IEEE Electrical Insulation Conf., Oct. 2005, pp. 159-162.
    • (2005) Proc. IEEE Electrical Insulation Conf. , pp. 159-162
    • Stone, G.C.1
  • 11
    • 80054696297 scopus 로고    scopus 로고
    • Rotating Electrical Machines-Part 27 PD Measurements on the Stator Winding Insulation of Rotating Machinery, Oct.
    • Rotating Electrical Machines-Part 27 PD Measurements on the Stator Winding Insulation of Rotating Machinery, IEC Standard IEC 60034, Oct. 2005.
    • (2005) IEC Standard IEC 60034
  • 12
    • 80054713269 scopus 로고    scopus 로고
    • Examples of premature stator winding failure in recently manufactured motors and generators
    • May
    • G. C. Stone, "Examples of premature stator winding failure in recently manufactured motors and generators," in Proc. INSUCON, May 2006, pp. 217-220.
    • (2006) Proc. INSUCON , pp. 217-220
    • Stone, G.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.