-
1
-
-
0024522668
-
Quality assurance problems in clinical hyperthermia and their impact on therapeutic outcome: A report by the radiation therapy oncology group
-
Perez CA, Gillespie B, Pajak T, Emami NB, Rubin P. Quality assurance problems in clinical hyperthermia and their impact on therapeutic outcome: A report by the radiation therapy oncology group. Int J Radiat Oncol Biol Phys 1989;16:551-558. (Pubitemid 19079691)
-
(1989)
International Journal of Radiation Oncology Biology Physics
, vol.16
, Issue.3
, pp. 551-558
-
-
Perez, C.A.1
Gillespie, B.2
Pajak, T.3
Hornback, N.B.4
Emami, B.5
Rubin, P.6
-
2
-
-
0025910656
-
Randomized phase III study comparing irradiation and hyperthermia with irradiation alone in superficial measurable tumors final report by the radiation therapy oncology group
-
Perez CA, Pajak T, Emami B, Hornback NB, Tupchong L, Rubin P. Randomized phase III study comparing irradiation and hyperthermia with irradiation alone in superficial measurable tumors. Final report by the radiation therapy oncology group. Am J Clin Oncol 1991;14:133-141.
-
(1991)
Am. J. Clin. Oncol.
, vol.14
, pp. 133-141
-
-
Perez, C.A.1
Pajak, T.2
Emami, B.3
Hornback, N.B.4
Tupchong, L.5
Rubin, P.6
-
3
-
-
0021226887
-
Will thermometric tomography become practical for hyperthermia treatment monitoring
-
Cetas CT. Will thermometric tomography become practical for hyperthermia treatment monitoring? Cancer Res 1984;44:4805s-4808s.
-
(1984)
Cancer Res.
, vol.44
-
-
Cetas, C.T.1
-
4
-
-
0003085051
-
A precise and fast temperature mapping using water proton chemical shift
-
Berlin Germany
-
Ishihara Y, Calderon A, Watanabe H, Mori K, Okamoto K, Suzuki Y, Sato K, Kuroda K, Nakagawa N, Tsutsumi S. A precise and fast temperature mapping using water proton chemical shift. Proceedings of the Society of Magnetic Resonance in Medicine, 11th Annual Meeting, Berlin, Germany, 1992, p. 4804.
-
(1992)
Proceedings of the Society of Magnetic Resonance in Medicine 11th Annual Meeting
, pp. 4804
-
-
Ishihara, Y.1
Calderon, A.2
Watanabe, H.3
Mori, K.4
Okamoto, K.5
Suzuki, Y.6
Sato, K.7
Kuroda, K.8
Nakagawa, N.9
Tsutsumi, S.10
-
5
-
-
0028785052
-
A precise and fast temperature mapping using water proton chemical shift
-
Ishihara Y, Calderon A, Watanabe H, Okamoto K, Suzuki Y, Kuroda K, Suzuki Y. A precise and fast temperature mapping using water proton chemical shift. Magn Reson Med 1995;34:814-823.
-
(1995)
Magn. Reson. Med.
, vol.34
, pp. 814-823
-
-
Ishihara, Y.1
Calderon, A.2
Watanabe, H.3
Okamoto, K.4
Suzuki, Y.5
Kuroda, K.6
Suzuki, Y.7
-
6
-
-
33745117579
-
Uterine leiomyomas: MR imaging- based thermometry and thermal dosimetry during focused ultrasound thermal ablation
-
McDannold N, Tempany CM, Fennessy FM, So MM, Rybicki FJ, Stewart EA, Jolesz FA, Hynynen K. Uterine leiomyomas: MR imaging-based thermometry and thermal dosimetry during focused ultrasound thermal ablation. Radiology 2006;240:263-272. (Pubitemid 43902618)
-
(2006)
Radiology
, vol.240
, Issue.1
, pp. 263-272
-
-
McDannold, N.1
Tempany, C.M.2
Fennessy, F.M.3
So, M.J.4
Rybicki, F.J.5
Stewart, E.A.6
Jolesz, F.A.7
Hynynen, K.8
-
7
-
-
21344475060
-
Noninvasive magnetic resonance thermography of recurrent rectal carcinoma in a 1.5 tesla hybrid system
-
DOI 10.1158/0008-5472.CAN-04-3952
-
Gellermann J, Wlodarczyk W, Hildebrandt B, Ganter H, Nicolau A, Rau B, Tilly W, Fähling H, Nadobny J, Felix R, Wust P. Noninvasive magnetic resonance thermography of recurrent rectal carcinoma in a 1.5 tesla hybrid system. Cancer Res 2005;63:5872-5880. (Pubitemid 40911193)
-
(2005)
Cancer Research
, vol.65
, Issue.13
, pp. 5872-5880
-
-
Gellermann, J.1
Wlodarczyk, W.2
Hildebrandt, B.3
Ganter, H.4
Nicolau, A.5
Rau, B.6
Tilly, W.7
Fahling, H.8
Nadobny, J.9
Felix, R.10
Wust, P.11
-
8
-
-
0022251670
-
Noninvasive thermometry using multiple-frequency-band radiometry: A feasibility study
-
DOI 10.1002/bem.2250060406
-
Prionas SD, Hahn GM. Noninvasive thermometry using multiple-frequency- band radiometry: A feasibility study. Bioelectromagnetics 1985;6:391-404. (Pubitemid 16253195)
-
(1985)
Bioelectromagnetics
, vol.6
, Issue.4
, pp. 391-404
-
-
Prionas, S.D.1
Hahn, G.M.2
-
9
-
-
0027628264
-
Tomographic measurement of temperature change in phantoms of the human body by chirp radar-type microwave computed tomography
-
Miyakawa M. Tomographic measurement of temperature change in phantoms of the human body by chirp radar-type microwave computed tomography. Med Biol Eng Comput 1993;31:S31-S36. (Pubitemid 23235786)
-
(1993)
Medical and Biological Engineering and Computing
, vol.31
, Issue.4 SUPPL.
-
-
Miyakawa, M.1
-
10
-
-
38049050628
-
A noninvasive temperature measurement regarding the heating applicator based on a reentrant cavity
-
Washington DC
-
Ishihara Y, Endo Y, Wadamori N, Ohwada H. A noninvasive temperature measurement regarding the heating applicator based on a reentrant cavity. Proceedings of 2007 Joint Annual Meeting of the World Conference on Interventional. Oncology (WCIO) and the Society for Thermal Medicine (STM), Washington, DC, 2007, pp. 232-233.
-
(2007)
Proceedings of 2007 Joint Annual Meeting of the World Conference on Interventional Oncology WCIO and the Society for Thermal Medicine STM
, pp. 232-233
-
-
Ishihara, Y.1
Endo, Y.2
Wadamori, N.3
Ohwada, H.4
-
11
-
-
57649210309
-
Noninvasive thermometry in a reentrant resonant cavity applicator
-
Lyon France 2007
-
Ishihara Y, Endo Y, Ohwada H, Wadamori N. Noninvasive thermometry in a reentrant resonant cavity applicator, Proceedings of the IEEE of the 29th Annual International Conference of the Engineering in Medicine and Biology Society, 2007, Lyon, France, 2007, pp. 1487-1490.
-
(2007)
Proceedings of the IEEE of the 29th Annual International Conference of the Engineering in Medicine and Biology Society
, pp. 1487-1490
-
-
Ishihara, Y.1
Endo, Y.2
Ohwada, H.3
Wadamori, N.4
-
12
-
-
80054067171
-
A fundamental numerical analysis for noninvasive thermometry integrated in a heating applicator based on the reentrant cavity
-
Ohwada H, Ishihara Y. A fundamental numerical analysis for noninvasive thermometry integrated in a heating applicator based on the reentrant cavity. Thermal Med 2010;26:51-62.
-
(2010)
Thermal. Med.
, vol.26
, pp. 51-62
-
-
Ohwada, H.1
Ishihara, Y.2
-
14
-
-
33847678464
-
Hyperthermia applicator based on reentrant cavity for localized head and neck tumors
-
Ishihara Y, Gotanda Y, Wadamori N, Matsuda J. Hyperthermia applicator based on reentrant cavity for localized head and neck tumors. Rev Sci Inst 2007;72:024301.1-024301.8.
-
(2007)
Rev. Sci. Inst.
, vol.72
, pp. 0243011-0243018
-
-
Ishihara, Y.1
Gotanda, Y.2
Wadamori, N.3
Matsuda, J.4
-
15
-
-
57649225522
-
Heating applicator based on reentrant cavity with optimized local heating characteristics
-
Ishihara Y, Wadamori N. Heating applicator based on reentrant cavity with optimized local heating characteristics. Int J Hyperthermia 2008;24:694-704.
-
(2008)
Int. J. Hyperthermia.
, vol.24
, pp. 694-704
-
-
Ishihara, Y.1
Wadamori, N.2
-
16
-
-
80054077782
-
Localized heating method by a rotatable applicator based on a reentrant cylindrical cavity
-
Tucson AZ USA
-
Ishihara Y, Kameyama Y, Wadamori N. Localized heating method by a rotatable applicator based on a reentrant cylindrical cavity. Proceedings of the Society for Thermal Medicine Annual Meeting, Tucson, AZ, USA, 2009, p. 172.
-
(2009)
Proceedings of the Society for Thermal Medicine Annual Meeting
, pp. 172
-
-
Ishihara, Y.1
Kameyama, Y.2
Wadamori, N.3
-
17
-
-
80054087161
-
Improvement in localized heating characteristics by loading dielectrics in a heating applicator based on a cylindrical reentrant cavity
-
Ishihara Y, Kameyama Y, Ino Y, Wadamori N. Improvement in localized heating characteristics by loading dielectrics in a heating applicator based on a cylindrical reentrant cavity. Thermal Med 2008;24:61-72.
-
(2008)
Thermal. Med.
, vol.24
, pp. 61-72
-
-
Ishihara, Y.1
Kameyama, Y.2
Ino, Y.3
Wadamori, N.4
-
18
-
-
1542606283
-
Tables of dielectric dispersion data for pure liquids and dilute solutions
-
Buckley F, Maryott AA. Tables of dielectric dispersion data for pure liquids and dilute solutions. Natl Bur Stand Circ 1958;589:1-6.
-
(1958)
Natl. Bur. Stand. Circ.
, vol.589
, pp. 1-6
-
-
Buckley, F.1
Maryott, A.A.2
-
19
-
-
0015033997
-
A coaxial cavity for measuring the dielectric properties of high permittivity materials
-
Pointon AJ, Woodman KF. A coaxial cavity for measuring the dielectric properties of high permittivity materials. J Phys E: Sci Instrum 1971;4:208-210.
-
(1971)
J Phys. E: Sci. Instrum.
, vol.4
, pp. 208-210
-
-
Pointon, A.J.1
Woodman, K.F.2
-
20
-
-
34250283667
-
Method of calculating dielectric permittivity in a partly filled resonator cavity
-
Karikh NM. Method of calculating dielectric permittivity in a partly filled resonator cavity. Meas Tech 1977;20:68-71.
-
(1977)
Meas. Tech.
, vol.20
, pp. 68-71
-
-
Karikh, N.M.1
-
21
-
-
0021692665
-
Formulas for preparing phantom muscle tissue at various radiofrequencies
-
Chou CK, Chen GW, Guy AW, Luk KH. Formulas for preparing phantom muscle tissue at various radiofrequencies. Bioelectromagnetics 1984;5:435-441.
-
(1984)
Bioelectromagnetics
, vol.5
, pp. 435-441
-
-
Chou, C.K.1
Chen, G.W.2
Guy, A.W.3
Luk, K.H.4
-
22
-
-
1842483939
-
Dielectric properties of tissue-equivalent liquids and their effects on specific absorption rate
-
Fukunaga K, Watanabe S, Yamanaka Y. Dielectric properties of tissue-equivalent liquids and their effects on specific absorption rate. IEEE Trans Electromagn Compat 2004;46:126-129.
-
(2004)
IEEE Trans. Electromagn. Compat.
, vol.46
, pp. 126-129
-
-
Fukunaga, K.1
Watanabe, S.2
Yamanaka, Y.3
-
23
-
-
33645305732
-
Ultrawideband temperature-dependent dielectric properties of animal liver tissue in the microwave frequency range
-
Lazebnik M, Converse MC, Booske JH, Hagness SC. Ultrawideband temperature-dependent dielectric properties of animal liver tissue in the microwave frequency range. Phys Med Biol 2006;51:1941-1955.
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 1941-1955
-
-
Lazebnik, M.1
Converse, M.C.2
Booske, J.H.3
Hagness, S.C.4
-
24
-
-
0035116428
-
Temperature quantification using the proton frequency shift technique: In vitro and in vivo validation in an open 0.5 Tesla interventional MR scanner during RF ablation
-
DOI 10.1002/jmri.1063
-
Botnar RM, Steiner P, Dubno B, Erhart P, von Schulthess GK, Debatin JF. Temperature quantification using the proton frequency shift technique: In vitro and in vivo validation in an open 0.5 tesla interventional MR scanner during RF ablation. J Magn Reson Imaging 2001;13:437-444. (Pubitemid 32173412)
-
(2001)
Journal of Magnetic Resonance Imaging
, vol.13
, Issue.3
, pp. 437-444
-
-
Botnar, R.M.1
Steiner, P.2
Dubno, B.3
Erhart, P.4
Von Schulthess, G.K.5
Debatin, J.F.6
|