메뉴 건너뛰기




Volumn 133, Issue 9, 2011, Pages

An efficient and accurate prediction of the stability of percutaneous fixation of acetabular fractures with finite element simulation

Author keywords

[No Author keywords available]

Indexed keywords

3D FINITE ELEMENT MODEL; ACCURATE PREDICTION; BIOMECHANICAL STABILITY; BLOOD LOSS; CONVENTIONAL APPROACH; FE MODEL; FE MODELING; FINITE ELEMENT MODELS; FINITE ELEMENT SIMULATIONS; INTERNAL FIXATION; MAXIMUM LOAD; OSTEOSYNTHESIS; PLATE FIXATION; SCREW FIXATION; SURGICAL PLANNING;

EID: 80054066517     PISSN: 01480731     EISSN: 15288951     Source Type: Journal    
DOI: 10.1115/1.4004821     Document Type: Article
Times cited : (15)

References (22)
  • 1
    • 0032621390 scopus 로고    scopus 로고
    • Fractures of the posterior wall of the acetabulum
    • Baumgaertner, M. R., 1999, "Fractures of the Posterior Wall of the Acetabulum," J. Am. Acad. Orthop. Surg., 7, pp. 54-65.
    • (1999) J. Am. Acad. Orthop. Surg. , vol.7 , pp. 54-65
    • Baumgaertner, M.R.1
  • 2
    • 0028912061 scopus 로고
    • Percutaneous iliosacral screw fixation: Early treatment for unstable posterior pelvic ring disruptions
    • Shuler, T. E., Boone, D. C., Gruen, G. S., and Peitzman, A. B., 1995, "Percutaneous Iliosacral Screw Fixation: Early Treatment for Unstable Posterior Pelvic Ring Disruptions," J. Trauma, 38, pp. 453-458.
    • (1995) J. Trauma , vol.38 , pp. 453-458
    • Shuler, T.E.1    Boone, D.C.2    Gruen, G.S.3    Peitzman, A.B.4
  • 3
    • 0031278144 scopus 로고    scopus 로고
    • Percutaneous fluoroscopic screw fixation of acetabular fractures
    • DOI 10.1016/S0020-1383(97)00097-1, PII S0020138397000971
    • Parker, P. J., and Copeland, C., 1997, "Percutaneous Fluroscopic Screw Fixation of Acetabular Fractures," Injury, 28, pp. 597-600. (Pubitemid 28185107)
    • (1997) Injury , vol.28 , Issue.9-10 , pp. 597-600
    • Parker, P.J.1    Copeland, C.2
  • 4
    • 0028036508 scopus 로고
    • Comminuted fractures of the posterior wall of the acetabulum. A biomechanical evaluation of fixation methods
    • Goulet, J. A., Rouleau, J. P., Mason, D. J., and Goldstein, S. A., 1994, "Comminuted Fractures of the Posterior Wall of the Acetabulum. A Biome-chanical Evaluation of Fixation Methods," J. Bone Joint Surg. Am., 76, pp. 1457-1463. (Pubitemid 24355961)
    • (1994) Journal of Bone and Joint Surgery - Series A , vol.76 , Issue.10 , pp. 1457-1463
    • Goulet, J.A.1    Rouleau, J.P.2    Mason, D.J.3    Goldstein, S.A.4
  • 5
    • 0033278657 scopus 로고    scopus 로고
    • Biomechanical evaluation of fixation of posterior acetabular wall fractures
    • discussion 260
    • Zoys, G. N., McGanity, P. L., Lanctot, D. R., Athanasiou, K. A., and Heckman, J. D., 1999, "Biomechanical Evaluation of Fixation of Posterior Acetabular Wall Fractures," J. South Orthop. Assoc., 8, pp. 254-260, discussion 260.
    • (1999) J. South Orthop. Assoc. , vol.8 , pp. 254-260
    • Zoys, G.N.1    McGanity, P.L.2    Lanctot, D.R.3    Athanasiou, K.A.4    Heckman, J.D.5
  • 8
    • 28444467708 scopus 로고    scopus 로고
    • The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures
    • DOI 10.1302/0301-620X.87B11.16614
    • Attias, N., Lindsey, R. W., Starr, A. J., Borer, D., Bridges, K., and Hipp, J. A., 2005, "The Use of a Virtual Three-Dimensional Model to Evaluate the Intraoss-eous Space Available for Percutaneous Screw Fixation of Acetabular Fractures," J. Bone Joint Surg. Br., 87, pp. 1520-1523. (Pubitemid 41723096)
    • (2005) Journal of Bone and Joint Surgery - Series B , vol.87 , Issue.11 , pp. 1520-1523
    • Attias, N.1    Lindsey, R.W.2    Starr, A.J.3    Borer, D.4    Bridges, K.5    Hipp, J.A.6
  • 9
    • 34147098889 scopus 로고    scopus 로고
    • Preoperative planning in pelvic and acetabular surgery: The value of advanced computerised planning modules
    • DOI 10.1016/j.injury.2007.01.033, PII S0020138307000319, Pelvic and Acetabular Surgery
    • Cimerman, M., and Kristan, A., 2007, "Preoperative Planning in Pelvic and Acetabular Surgery: The Value of Advanced Computerised Planning Modules," Injury, 38, pp. 442-449. (Pubitemid 46574641)
    • (2007) Injury , vol.38 , Issue.4 , pp. 442-449
    • Cimerman, M.1    Kristan, A.2
  • 10
    • 77952582493 scopus 로고    scopus 로고
    • Finite element analysis of acetabular fractures-development and validation with a synthetic pelvis
    • Shim, V., Bohme, J., Vaitl, P., Klima, S., Josten, C., and Anderson, I., 2010, "Finite Element Analysis of Acetabular Fractures-Development and Validation With a Synthetic Pelvis," J. Biomech., 43, pp. 1635-1639.
    • (2010) J. Biomech. , vol.43 , pp. 1635-1639
    • Shim, V.1    Bohme, J.2    Vaitl, P.3    Klima, S.4    Josten, C.5    Anderson, I.6
  • 11
    • 0019058769 scopus 로고
    • Acetabulum fractures: Classification and management
    • Letournel, E., 1980, "Acetabulum Fractures: Classification and Management," Clin. Orthop. Relat. Res., 151, pp. 81-106.
    • (1980) Clin. Orthop. Relat. Res. , vol.151 , pp. 81-106
    • Letournel, E.1
  • 12
    • 33751529487 scopus 로고    scopus 로고
    • The use of sparse CT datasets for auto-generating accurate FE models of the femur and pelvis
    • DOI 10.1016/j.jbiomech.2005.11.018, PII S002192900500535X
    • Shim, V. B., Pitto, R. P., Streicher, R. M., Hunter, P. J., Anderson, I. A., 2007, "The Use of Sparse CT Datasets for Auto-generating Accurate FE Models of the Femur and Pelvis," J. Biomech., 40, pp. 26-35. (Pubitemid 44838700)
    • (2007) Journal of Biomechanics , vol.40 , Issue.1 , pp. 26-35
    • Shim, V.B.1    Pitto, R.P.2    Streicher, R.M.3    Hunter, P.J.4    Anderson, I.A.5
  • 13
    • 0031035760 scopus 로고    scopus 로고
    • Geometric modeling of the human torso using cubic hermite elements
    • Bradley, C. P., Pullan, A. J., and Hunter, P. J., 1997, "Geometric Modeling of the Human Torso Using Cubic Hermite Elements," Ann. Biomed. Eng., 25, pp. 96-111. (Pubitemid 27053912)
    • (1997) Annals of Biomedical Engineering , vol.25 , Issue.1 , pp. 96-111
    • Bradley, C.P.1    Pullan, A.J.2    Hunter, P.J.3
  • 14
    • 56349146883 scopus 로고    scopus 로고
    • Development and validation of patient-specific finite element models of the hemipelvis generated from a sparse CT data set
    • Shim, V. B., Pitto, R. P., Streicher, R. M., Hunter, P. J., and Anderson, I. A., 2008, "Development and Validation of Patient-Specific Finite Element Models of the Hemipelvis Generated From a Sparse CT Data Set," ASME J. Biomech. Eng., 130, p. 051010.
    • (2008) ASME J. Biomech. Eng. , vol.130 , pp. 051010
    • Shim, V.B.1    Pitto, R.P.2    Streicher, R.M.3    Hunter, P.J.4    Anderson, I.A.5
  • 17
    • 0142168925 scopus 로고    scopus 로고
    • Biomechanical testing of the LCP-How Can Stability in locked internal fixators be controlled?
    • Stoffel, K., Dieter, U., Stachowiak, G., Gachter, A., and Kuster, M. S., 2003, "Biomechanical Testing of the LCP-How Can Stability in Locked Internal Fixators Be Controlled?," Injury, 34, Suppl 2, p. B11-9.
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Stoffel, K.1    Dieter, U.2    Stachowiak, G.3    Gachter, A.4    Kuster, M.S.5
  • 18
    • 0026864111 scopus 로고
    • Finite-Element modelling of femoral shaft fracture fixation techniques post total hip arthroplasty
    • Mihalko, W. M., Beaudoin, A. J., Cardea, J. A., and Krause, W. R., 1992, "Finite-Element Modelling of Femoral Shaft Fracture Fixation Techniques Post Total Hip Arthroplasty," J. Biomech., 25, pp. 469-476.
    • (1992) J. Biomech. , vol.25 , pp. 469-476
    • Mihalko, W.M.1    Beaudoin, A.J.2    Cardea, J.A.3    Krause, W.R.4
  • 19
    • 0033760015 scopus 로고    scopus 로고
    • Three-Dimensional finite element analysis of several internal and external pelvis fixations
    • Garcia, J. M., Doblare, M., Seral, B., Seral, F., Palanca, D., and Gracia, L., 2000, "Three-Dimensional Finite Element Analysis of Several Internal and External Pelvis Fixations," ASME J. Biomech. Eng., 122, pp. 516-522.
    • (2000) ASME J. Biomech. Eng. , vol.122 , pp. 516-522
    • Garcia, J.M.1    Doblare, M.2    Seral, B.3    Seral, F.4    Palanca, D.5    Gracia, L.6
  • 20
    • 0036144837 scopus 로고    scopus 로고
    • An analysis of bone stresses and fixation stability using a finite element model of simulated distal radius fractures
    • DOI 10.1053/jhsu.2002.29485
    • Rogge, R. D., Adams, B. D., and Goel, V. K., 2002, "An Analysis of Bone Stresses and Fixation Stability Using a Finite Element Model of Simulated Distal Radius Fractures," J. Hand Surg. Am., 27, pp. 86-92. (Pubitemid 34072599)
    • (2002) Journal of Hand Surgery , vol.27 , Issue.1 , pp. 86-92
    • Rogge, R.D.1    Adams, B.D.2    Goel, V.K.3
  • 21
    • 70350520037 scopus 로고    scopus 로고
    • Effects of positioning and notching of resurfaced femurs on femoral neck strength: A biomechanical test
    • Nabavi, A., Yeoh, K. M., Shidiac, L., Appleyard, R., Gillies, R. M., and Turn-bull, A., 2009, "Effects of Positioning and Notching of Resurfaced Femurs on Femoral Neck Strength: A Biomechanical Test," J. Orthop. Surg., 17, pp. 47-50.
    • (2009) J. Orthop. Surg. , vol.17 , pp. 47-50
    • Nabavi, A.1    Yeoh, K.M.2    Shidiac, L.3    Appleyard, R.4    Gillies, R.M.5    Turn-Bull, A.6