메뉴 건너뛰기




Volumn 32, Issue 9, 2011, Pages 1714-1720

Parent vessel size and curvature strongly influence risk of incomplete stent apposition in enterprise intracranial aneurysm stent coiling

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BRAIN BLOOD VESSEL; CLINICAL ARTICLE; COHORT ANALYSIS; COIL EMBOLIZATION; GEOMETRY; HUMAN; INTERNAL CAROTID ARTERY ANEURYSM; INTRACRANIAL ANEURYSM; MAGNETIC RESONANCE ANGIOGRAPHY; STENT; TECHNIQUE;

EID: 80054010623     PISSN: 01956108     EISSN: 1936959X     Source Type: Journal    
DOI: 10.3174/ajnr.A2584     Document Type: Article
Times cited : (66)

References (24)
  • 1
    • 33746760128 scopus 로고    scopus 로고
    • Endovascular procedures for treating wide-necked aneurysms
    • Wells-Roth D, Biondi A, Janardhan V, et al. Endovascular procedures for treating wide-necked aneurysms. Neurosurg Focus 2005;18:E7
    • (2005) Neurosurg Focus , vol.18
    • Wells-Roth, D.1    Biondi, A.2    Janardhan, V.3
  • 2
    • 0034520927 scopus 로고    scopus 로고
    • Stent-supported coil embolization: The treatment of fusiform and wide-neck aneurysms and pseudoaneurysms
    • discussion 113-15
    • Phatouros CC, Sasaki TY, Higashida RT, et al. Stent-supported coil embolization: the treatment of fusiform and wide-neck aneurysms and pseudoaneurysms. Neurosurgery 2000;47:107-13, discussion 113-15
    • (2000) Neurosurgery , vol.47 , pp. 107-113
    • Phatouros, C.C.1    Sasaki, T.Y.2    Higashida, R.T.3
  • 3
    • 26044460227 scopus 로고    scopus 로고
    • Stent-assisted coil embolization of intracranial wide-necked aneurysms
    • DOI 10.1007/s00234-005-1402-8
    • Lee YJ, Kim DJ, Suh SH, et al. Stent-assisted coil embolization of intracranial wide-necked aneurysms. Neuroradiology 2005;47:680-89 (Pubitemid 41403611)
    • (2005) Neuroradiology , vol.47 , Issue.9 , pp. 680-689
    • Lee, Y.-J.1    Kim, D.J.2    Suh, S.H.3    Lee, S.-K.4    Kim, J.5    Kim, D.I.6
  • 4
    • 0345737198 scopus 로고    scopus 로고
    • Stent assisted coil embolization: The treatment of wide-necked, dissecting, and fusiform aneurysms
    • Irie K, Negoro M, Hayakawa M, et al. Stent assisted coil embolization: the treatment of wide-necked, dissecting, and fusiform aneurysms. Interv Neuroradiol 2003;9:255-61 (Pubitemid 38049292)
    • (2003) Interventional Neuroradiology , vol.9 , Issue.3 , pp. 255-261
    • Irie, K.1    Negoro, M.2    Hayakawa, M.3    Eayashi, J.4    Kanno, T.5
  • 5
    • 67349121046 scopus 로고    scopus 로고
    • Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: Mid-term and long-term results
    • Sedat J, Chau Y, Mondot L, et al. Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results. Neuroradiology 2009;51:401-09
    • (2009) Neuroradiology , vol.51 , pp. 401-409
    • Sedat, J.1    Chau, Y.2    Mondot, L.3
  • 6
    • 33646192862 scopus 로고    scopus 로고
    • Increased cell opening and prolapse ofstruts of a Neuroform stent in curved vasculature: Value of angiographic computed tomography - Technical case report
    • discussion ONS-E380
    • Benndorf G, Claus B, Strother CM, et al. Increased cell opening and prolapse ofstruts of a Neuroform stent in curved vasculature: value of angiographic computed tomography - technical case report. Neurosurgery 2006;58:ONS-E380, discussion ONS-E380
    • (2006) Neurosurgery , vol.58
    • Benndorf, G.1    Claus, B.2    Strother, C.M.3
  • 7
    • 34248639072 scopus 로고    scopus 로고
    • Stent conformity in curved vascular models with simulated aneurysm weeks using Flat-Panel CT: An in vitro study
    • Ebrahimi N, Claus B, Lee CY, et al. Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study. AJNR Am J Neuroradiol 2007;28:823-29 (Pubitemid 46776055)
    • (2007) American Journal of Neuroradiology , vol.28 , Issue.5 , pp. 823-829
    • Ebrahimi, N.1    Claus, B.2    Lee, C.-Y.3    Biondi, A.4    Benndorf, G.5
  • 8
    • 68849100613 scopus 로고    scopus 로고
    • Incomplete stent apposition after coronary stent implantation: Myth or reality?
    • Rathore S, Terashima M, Habara M, et al. Incomplete stent apposition after coronary stent implantation: myth or reality? J Interv Cardiol 2009;22:341-49
    • (2009) J Interv Cardiol , vol.22 , pp. 341-349
    • Rathore, S.1    Terashima, M.2    Habara, M.3
  • 9
    • 77957281141 scopus 로고    scopus 로고
    • Strut apposition after coronary stent implantation visualised with optical coherence tomography
    • Radu M, Jorgensen E, Kelbaek H, et al. Strut apposition after coronary stent implantation visualised with optical coherence tomography. EuroIntervention 2010;6:86-93
    • (2010) EuroIntervention , vol.6 , pp. 86-93
    • Radu, M.1    Jorgensen, E.2    Kelbaek, H.3
  • 11
    • 48749100649 scopus 로고    scopus 로고
    • Coexistent in-stent restenosis, late incomplete stent apposition and mural thrombus in a zotarolimus-eluting stent
    • Zhang F, Qian J, Ge J. Coexistent in-stent restenosis, late incomplete stent apposition and mural thrombus in a zotarolimus-eluting stent. J Invasive Cardiol 2008;20:423-25
    • (2008) J Invasive Cardiol , vol.20 , pp. 423-425
    • Zhang, F.1    Qian, J.2    Ge, J.3
  • 12
    • 33646203122 scopus 로고    scopus 로고
    • Intra/extra-aneurysmal stent placement for management of complex and wide-necked- bifurcation aneurysms: Eight cases using the waffle cone technique
    • discussion ONS-262
    • Horowitz M, Levy E, Sauvageau E, et al. Intra/extra-aneurysmal stent placement for management of complex and wide-necked- bifurcation aneurysms: eight cases using the waffle cone technique. Neurosurgery 2006;58:ONS-258-262, discussion ONS-262
    • (2006) Neurosurgery , vol.58
    • Horowitz, M.1    Levy, E.2    Sauvageau, E.3
  • 13
    • 65649143549 scopus 로고    scopus 로고
    • Use of Dyna-CT angiography in neuroendovascular decision-making: A case report
    • Epub 2009 Apr 15
    • Namba K, Niimi Y, Song JK, et al. Use of Dyna-CT angiography in neuroendovascular decision-making: a case report. Interv Neuroradiol 2009;15:67-72. Epub 2009 Apr 15
    • (2009) Interv Neuroradiol , vol.15 , pp. 67-72
    • Namba, K.1    Niimi, Y.2    Song, J.K.3
  • 14
    • 67349097399 scopus 로고    scopus 로고
    • High-resolution CT and angiographic evaluation of NexStent wall adaptation
    • Nemes B, Lukacs L, Balazs G, et al. High-resolution CT and angiographic evaluation of NexStent wall adaptation. Cardiovasc Intervent Radiol 2009;32:436-40
    • (2009) Cardiovasc Intervent Radiol , vol.32 , pp. 436-440
    • Nemes, B.1    Lukacs, L.2    Balazs, G.3
  • 15
    • 34547728662 scopus 로고    scopus 로고
    • Effect of the polymer-based, paclitaxeleluting TAXUS Express stent on vascular tissue responses: A volumetric intravascular ultrasound integrated analysis from the TAXUS IV, V, and VI trials
    • Epub 2007 May 31
    • Weissman NJ, Ellis SG, Grube E, et al. Effect of the polymer-based, paclitaxeleluting TAXUS Express stent on vascular tissue responses: a volumetric intravascular ultrasound integrated analysis from the TAXUS IV, V, and VI trials. Eur Heart J 2007;28:1574-82. Epub 2007 May 31
    • (2007) Eur Heart J , vol.28 , pp. 1574-1582
    • Weissman, N.J.1    Ellis, S.G.2    Grube, E.3
  • 18
    • 0345526804 scopus 로고    scopus 로고
    • Long-Term Follow-Up of Incomplete Stent Apposition in Patients Who Received Sirolimus-Eluting Stent for De Novo Coronary Lesions: An Intravascular Ultrasound Analysis
    • DOI 10.1161/01.CIR.0000103666.25660.77
    • Degertekin M, Serruys PW, Tanabe K, et al. Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions: an intravascular ultrasound analysis. Circulation 2003;108:2747-50 (Pubitemid 37498975)
    • (2003) Circulation , vol.108 , Issue.22 , pp. 2747-2750
    • Degertekin, M.1    Serruys, P.W.2    Tanabe, K.3    Lee, C.H.4    Sousa, J.E.5    Colombo, A.6    Morice, M.-C.7    Ligthart, J.M.R.8    De Feyter, P.J.9
  • 19
    • 39749127135 scopus 로고    scopus 로고
    • Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: Intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials
    • Epub 2007 Aug 29
    • Hoffmann R, Morice MC, Moses JW, et al. Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials. Heart 2008;94:322-28. Epub 2007 Aug 29
    • (2008) Heart , vol.94 , pp. 322-328
    • Hoffmann, R.1    Morice, M.C.2    Moses, J.W.3
  • 21
    • 56849093972 scopus 로고    scopus 로고
    • Delayed migration of a self-expanding intracranial microstent
    • Kelly ME, Turner RD, Moskowitz SI, et al. Delayed migration of a self-expanding intracranial microstent. AJNR Am J Neuroradiol 2008;29:1959-60
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 1959-1960
    • Kelly, M.E.1    Turner, R.D.2    Moskowitz, S.I.3
  • 23
    • 67650742249 scopus 로고    scopus 로고
    • Spontaneous delayed proximal migration of Enterprise stent after staged treatment of wide-necked basilar aneurysm: Technical case report
    • discussion E1012
    • Lavine SD, Meyers PM, Connolly ES, et al.. Spontaneous delayed proximal migration of Enterprise stent after staged treatment of wide-necked basilar aneurysm: technical case report. Neurosurgery 2009;64:E1012, discussion E1012
    • (2009) Neurosurgery , vol.64
    • Lavine, S.D.1    Meyers, P.M.2    Connolly, E.S.3
  • 24
    • 77749251801 scopus 로고    scopus 로고
    • Use of a vascular reconstruction device to salvage acute ischemic occlusions refractory to traditional endovascular recanalization methods
    • Mocco J, Hanel RA, Sharma J, et al. Use of a vascular reconstruction device to salvage acute ischemic occlusions refractory to traditional endovascular recanalization methods. J Neurosurg 112:557-62
    • J Neurosurg , vol.112 , pp. 557-562
    • Mocco, J.1    Hanel, R.A.2    Sharma, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.