메뉴 건너뛰기




Volumn 2, Issue , 2007, Pages 1480-1490

Experimental investigation of bolt loosening detection in thermal protection panels at high temperature

Author keywords

Health monitoring; Piezoelectric active sensors: Bolt loosening; Thermal protection system (TPS)

Indexed keywords

BOLT TIGHTENING; BOLTS; HEAT SHIELDING; LOCKS (FASTENERS); MONITORING; PIEZOELECTRICITY; THERMAL INSULATING MATERIALS;

EID: 80053986048     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (7)

References (15)
  • 2
    • 25144498201 scopus 로고    scopus 로고
    • Design of a hierarchical health monitoring system for detection of multilevel damage in boiled thermal protection panels: A preliminary study
    • Yang J. Chang F. K. and Derriso M. M. "Design of a hierarchical health monitoring system for detection of multilevel damage in boiled thermal protection panels: a preliminary study". Structure Health Monitoring. Vol. 2. pp 115-122. 2003.
    • (2003) Structure Health Monitoring , vol.2 , pp. 115-122
    • Yang, J.1    Chang, F.K.2    Derriso, M.M.3
  • 4
    • 1942422230 scopus 로고    scopus 로고
    • The structural health monitoring of a mechanically attached thermal protection system
    • Derriso M. M. Braistcd W. Koscnslengel J. and DeSimio M. "The structural health monitoring of a mechanically attached thermal protection system". JOM. Vol. 56. No. 3. pp 36-39. 2004.
    • (2004) JOM , vol.56 , Issue.3 , pp. 36-39
    • Derriso, M.M.1    Braistcd, W.2    Koscnslengel, J.3    DeSimio, M.4
  • 8
    • 85087535009 scopus 로고    scopus 로고
    • Design and performance of wireless sensors for structural health monitoring
    • Walters D. G., Layaweera P. and Bahr A. J., "Design and performance of wireless sensors for structural health monitoring". Structura/Engineering and Mechanics. Vol. 17. No. 3-4. pp 393-408. 2004.
    • (2004) Structura/Engineering and Mechanics , vol.17 , Issue.3-4 , pp. 393-408
    • Walters, D.G.1    Layaweera, P.2    Bahr, A.J.3
  • 12
    • 25144508783 scopus 로고    scopus 로고
    • Verification of a built-in health monitoring system for boiled thermal protection panels
    • San Diego. CA. USA
    • Yang. J. and Chang F. K. "Verification of a built-in health monitoring system for boiled thermal protection panels" Proceedings of SPIE-The International Society for Optical Engineering, Vol. 5765. San Diego. CA. USA. pp 769-780. 2005.
    • (2005) Proceedings of SPIE-The International Society for Optical Engineering , vol.5765 , pp. 769-780
    • Yang, J.1    Chang, F.K.2
  • 13
    • 33645034126 scopus 로고    scopus 로고
    • Detection ol boll loosening in C-C composite thermal protection panels: I. Diagnostic principle
    • Yang J. and Chang E. K. "Detection ol boll loosening in C-C composite thermal protection panels: I. Diagnostic principle". Simirt Materials ami Structures. Vol. 15. No. 2. pp 581-590. 2011.
    • (2011) Simirt Materials Ami Structures , vol.15 , Issue.2 , pp. 581-590
    • Yang, J.1    Chang, E.K.2
  • 14
    • 33645017120 scopus 로고    scopus 로고
    • Detection of bolt loosening in C-C composite thermal protection panels: II. Experimental verification
    • Yane J. and Chang E.K. "Detection of bolt loosening in C-C composite thermal protection panels: II. Experimental verification". Smart Materials anil Structures. Vol. 15. No. 2. pp 591-599.2006.
    • (2006) Smart Materials Anil Structures , vol.15 , Issue.2 , pp. 591-599
    • Yane, J.1    Chang, E.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.