메뉴 건너뛰기




Volumn 26, Issue 9, 2011, Pages 910-916

Arthroscopic rotator cuff repair: A biomechanical comparison of the suture-bridge technique vs. a new transosseous technique using SutureButtons®

Author keywords

Rotator cuff repair transosseous; Suture bridge; Transosseous equivalent arthroscopy

Indexed keywords

BIOMECHANICAL PROPERTIES; CYCLIC DISPLACEMENTS; GAP FORMATION; LINEAR STIFFNESS; MEAN AGES; ROTATOR CUFF; ROTATOR CUFF REPAIR - TRANSOSSEOUS; SURGICAL TECHNIQUES; SUTURE ANCHOR; SUTURE-BRIDGE; TRANSOSSEOUS-EQUIVALENT - ARTHROSCOPY; ULTIMATE LOADS; YIELD LOAD;

EID: 80053899482     PISSN: 02680033     EISSN: 18791271     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2011.05.012     Document Type: Article
Times cited : (16)

References (39)
  • 1
    • 27544450312 scopus 로고    scopus 로고
    • Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques
    • DOI 10.1177/0363546505278252
    • C.S. Ahmad, A.M. Stewart, R. Izquierdo, and L.U. Bigliani Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques Am. J. Sports Med. 33 2005 1667 1671 (Pubitemid 41546740)
    • (2005) American Journal of Sports Medicine , vol.33 , Issue.11 , pp. 1667-1671
    • Ahmad, C.S.1    Stewart, A.M.2    Izquierdo, R.3    Bigliani, L.U.4
  • 3
    • 70749092328 scopus 로고    scopus 로고
    • A biomechanical comparison of transosseous-suture anchor and suture bridge rotator cuff repairs in cadavers
    • L.J. Bisson, and L.M. Manohar A biomechanical comparison of transosseous-suture anchor and suture bridge rotator cuff repairs in cadavers Am. J. Sports Med. 37 2009 1991 1995
    • (2009) Am. J. Sports Med. , vol.37 , pp. 1991-1995
    • Bisson, L.J.1    Manohar, L.M.2
  • 4
    • 0033971525 scopus 로고    scopus 로고
    • A stepwise approach to arthroscopic rotator cuff repair based on biomechanical principles
    • S.S. Burkhart A stepwise approach to arthroscopic rotator cuff repair based on biomechanical principles Arthroscopy 16 2000 82 90 (Pubitemid 30043468)
    • (2000) Arthroscopy , vol.16 , Issue.1 , pp. 82-90
    • Burkhart, S.S.1
  • 5
    • 0030900130 scopus 로고    scopus 로고
    • Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure
    • DOI 10.1016/S0749-8063(97)90151-1
    • S.S. Burkhart, T.C. Johnson, M.A. Wirth, and K.A. Athanasiou Cyclic loading of transosseous rotator cuff repairs: tension overload as a possible cause of failure Arthroscopy 13 1997 172 176 (Pubitemid 27209562)
    • (1997) Arthroscopy , vol.13 , Issue.2 , pp. 172-176
    • Burkhart, S.S.1    Johnson, T.C.2    Wirth, M.A.3    Athanasiou, K.A.4
  • 7
    • 34249879850 scopus 로고    scopus 로고
    • Arthroscopic Rotator Cuff Repairs: An Anatomic and Biomechanical Rationale for Different Suture-Anchor Repair Configurations
    • DOI 10.1016/j.arthro.2007.02.018, PII S074980630700271X
    • B.J. Cole, N.S. Elattrache, and A. Anbari Arthroscopic rotator cuff repairs: an anatomic and biomechanical rationale for different suture-anchor repair configurations Arthroscopy 23 2007 662 669 (Pubitemid 46873904)
    • (2007) Arthroscopy - Journal of Arthroscopic and Related Surgery , vol.23 , Issue.6 , pp. 662-669
    • Cole, B.J.1    ElAttrache, N.S.2    Anbari, A.3
  • 9
    • 49949109967 scopus 로고    scopus 로고
    • A novel transosseous button technique for rotator cuff repair
    • M.P. Fox, A. Auffarth, M. Tauber, A. Hartmann, and H. Resch A novel transosseous button technique for rotator cuff repair Arthroscopy 24 2008 1074 1077
    • (2008) Arthroscopy , vol.24 , pp. 1074-1077
    • Fox, M.P.1    Auffarth, A.2    Tauber, M.3    Hartmann, A.4    Resch, H.5
  • 11
    • 34447560059 scopus 로고    scopus 로고
    • Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: A randomized controlled trial
    • DOI 10.1177/0363546507302218
    • F. Franceschi, L. Ruzzini, U.G. Longo, F.M. Martina, B.B. Zobel, and N. Maffulli Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: a randomized controlled trial Am. J. Sports Med. 35 2007 1254 1260 (Pubitemid 47084206)
    • (2007) American Journal of Sports Medicine , vol.35 , Issue.8 , pp. 1254-1260
    • Franceschi, F.1    Ruzzini, L.2    Longo, U.G.3    Martina, F.M.4    Beomonte Zobel, B.5    Maffulli, N.6    Denaro, V.7
  • 12
  • 14
    • 0031033951 scopus 로고    scopus 로고
    • Full-thickness tears: Arthroscopic repair
    • DOI 10.1016/S0030-5898(05)70267-4
    • G.M. Gartsman, and S.M. Hammerman Full-thickness tears: arthroscopic repair Orthop. Clin. North Am. 28 1997 83 98 (Pubitemid 27057143)
    • (1997) Orthopedic Clinics of North America , vol.28 , Issue.1 , pp. 83-98
    • Gartsman, G.M.1    Hammerman, S.M.2
  • 17
    • 57849087668 scopus 로고    scopus 로고
    • Single-row versus double-row arthroscopic rotator cuff repair: A prospective randomized clinical study
    • A. Grasso, G. Milano, M. Salvatore, G. Falcone, L. Deriu, and C. Fabbriciani Single-row versus double-row arthroscopic rotator cuff repair: a prospective randomized clinical study Arthroscopy 25 2009 4 12
    • (2009) Arthroscopy , vol.25 , pp. 4-12
    • Grasso, A.1    Milano, G.2    Salvatore, M.3    Falcone, G.4    Deriu, L.5    Fabbriciani, C.6
  • 19
    • 27544511812 scopus 로고    scopus 로고
    • Arthroscopic transtendon repair of partial-thickness articular-side tears of the rotator cuff: Anatomical clinical study
    • DOI 10.1177/0363546505277141
    • J. Ide, S. Maeda, and K. Takagi Arthroscopic transtendon repair of partial-thickness articular-side tears of the rotator cuff: anatomical and clinical study Am. J. Sports Med. 33 2005 1672 1679 (Pubitemid 41546741)
    • (2005) American Journal of Sports Medicine , vol.33 , Issue.11 , pp. 1672-1679
    • Ide, J.1    Maeda, S.2    Takagi, K.3
  • 22
    • 0242678574 scopus 로고    scopus 로고
    • Double-Row Arthroscopic Rotator Cuff Repair: Re-Establishing the Footprint of the Rotator Cuff
    • DOI 10.1016/j.arthro.2003.09.036
    • I.K. Lo, and S.S. Burkhart Double-row arthroscopic rotator cuff repair: re-establishing the footprint of the rotator cuff Arthroscopy 19 2003 1035 1042 (Pubitemid 37429591)
    • (2003) Arthroscopy - Journal of Arthroscopic and Related Surgery , vol.19 , Issue.9 , pp. 1035-1042
    • Lo, I.K.Y.1    Burkhart, S.S.2
  • 23
    • 31844453610 scopus 로고    scopus 로고
    • Biomechanical evaluation of arthroscopic rotator cuff repairs: Double-row compared with single-row fixation
    • DOI 10.2106/JBJS.D.02887
    • C.B. Ma, L. Comerford, J. Wilson, and C.M. Puttlitz Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation J. Bone Joint Surg. Am. 88 2006 403 410 (Pubitemid 43185144)
    • (2006) Journal of Bone and Joint Surgery - Series A , vol.88 , Issue.2 , pp. 403-410
    • Ma, C.B.1    Comerford, L.2    Wilson, J.3    Puttlitz, C.M.4
  • 25
    • 80053914967 scopus 로고
    • Lesion of the musculotendinous cuff of the shoulder. the exposure and treatment of tears with retraction
    • H.L. Mc Laughlin Lesion of the musculotendinous cuff of the shoulder. The exposure and treatment of tears with retraction J. Bone Joint Surg. Am. 26 1944 20
    • (1944) J. Bone Joint Surg. Am. , vol.26 , pp. 20
    • Mc Laughlin, H.L.1
  • 26
    • 33750442166 scopus 로고    scopus 로고
    • The Effect of Double-Row Fixation on Initial Repair Strength in Rotator Cuff Repair: A Biomechanical Study
    • DOI 10.1016/j.arthro.2006.07.004, PII S0749806306008772
    • S.W. Meier, and J.D. Meier The effect of double-row fixation on initial repair strength in rotator cuff repair: a biomechanical study Arthroscopy 22 2006 1168 1173 (Pubitemid 44648672)
    • (2006) Arthroscopy - Journal of Arthroscopic and Related Surgery , vol.22 , Issue.11 , pp. 1168-1173
    • Meier, S.W.1    Meier, J.D.2
  • 28
    • 33845194732 scopus 로고    scopus 로고
    • "transosseous-equivalent" rotator cuff repair technique
    • M.C. Park, N.S. Elattrache, C.S. Ahmad, and J.E. Tibone "Transosseous-equivalent" rotator cuff repair technique Arthroscopy 22 1360 2006 e1 e5
    • (2006) Arthroscopy , vol.22 , Issue.1360
    • Park, M.C.1    Elattrache, N.S.2    Ahmad, C.S.3    Tibone, J.E.4
  • 29
    • 34447568149 scopus 로고    scopus 로고
    • Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
    • DOI 10.1016/j.jse.2006.09.010, PII S1058274606003168
    • M.C. Park, N.S. Elattrache, J.E. Tibone, C.S. Ahmad, B.J. Jun, and T.Q. Lee Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique J. Shoulder Elbow Surg. 16 2007 461 468 (Pubitemid 47081400)
    • (2007) Journal of Shoulder and Elbow Surgery , vol.16 , Issue.4 , pp. 461-468
    • Park, M.C.1    ElAttrache, N.S.2    Tibone, J.E.3    Ahmad, C.S.4    Jun, B.-J.5    Lee, T.Q.6
  • 30
    • 34250661991 scopus 로고    scopus 로고
    • Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
    • DOI 10.1016/j.jse.2006.09.011, PII S105827460600317X
    • M.C. Park, J.E. Tibone, N.S. Elattrache, C.S. Ahmad, B.J. Jun, and T.Q. Lee Part II: biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique J. Shoulder Elbow Surg. 16 2007 469 476 (Pubitemid 47081401)
    • (2007) Journal of Shoulder and Elbow Surgery , vol.16 , Issue.4 , pp. 469-476
    • Park, M.C.1    Tibone, J.E.2    ElAttrache, N.S.3    Ahmad, C.S.4    Jun, B.-J.5    Lee, T.Q.6
  • 31
    • 77952486023 scopus 로고    scopus 로고
    • Does an arthroscopic suture bridge technique maintain repair integrity?: A serial evaluation by ultrasonography
    • J.Y. Park, H.T. Siti, J.S. Keum, S.G. Moon, and K.S. Oh Does an arthroscopic suture bridge technique maintain repair integrity?: a serial evaluation by ultrasonography Clin. Orthop. Relat. Res. 468 2010 1578 1587
    • (2010) Clin. Orthop. Relat. Res. , vol.468 , pp. 1578-1587
    • Park, J.Y.1    Siti, H.T.2    Keum, J.S.3    Moon, S.G.4    Oh, K.S.5
  • 33
    • 34249909234 scopus 로고    scopus 로고
    • Clinical Evidence Shows No Difference Between Single- and Double-Row Repair for Rotator Cuff Tears
    • DOI 10.1016/j.arthro.2007.01.031, PII S0749806307002435
    • D.J. Reardon, and N. Maffulli Clinical evidence shows no difference between single- and double-row repair for rotator cuff tears Arthroscopy 23 2007 670 673 (Pubitemid 46873902)
    • (2007) Arthroscopy - Journal of Arthroscopic and Related Surgery , vol.23 , Issue.6 , pp. 670-673
    • Reardon, D.J.1    Maffulli, N.2
  • 34
    • 0030022850 scopus 로고    scopus 로고
    • Full-thickness rotator cuff tears: A biomechanical comparison of suture versus bone anchor techniques
    • S.C. Reed, N. Glossop, and D.J. Ogilvie-Harris Full-thickness rotator cuff tears. A biomechanical comparison of suture versus bone anchor techniques Am. J. Sports Med. 24 1996 46 48 (Pubitemid 26036326)
    • (1996) American Journal of Sports Medicine , vol.24 , Issue.1 , pp. 46-48
    • Reed, S.C.1    Glossop, N.2    Ogilvie-Harris, D.J.3
  • 35
    • 0030917386 scopus 로고    scopus 로고
    • Technique of arthroscopic rotator cuff repair using implantable 4-mm revo suture anchors, suture shuttle relays, and no. 2 nonabsorbable mattress sutures
    • S.J. Snyder Technique of arthroscopic rotator cuff repair using implantable 4-mm Revo suture anchors, suture shuttle relays, and no. 2 nonabsorbable mattress sutures Orthop. Clin. North Am. 28 1997 267 275 (Pubitemid 27199645)
    • (1997) Orthopedic Clinics of North America , vol.28 , Issue.2 , pp. 267-275
    • Snyder, S.J.1
  • 36
    • 28444453275 scopus 로고    scopus 로고
    • Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: Single-row versus dual-row fixation
    • DOI 10.1016/j.arthro.2005.08.011, PII S0749806305011758
    • H. Sugaya, K. Maeda, K. Matsuki, and J. Moriishi Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation Arthroscopy 21 2005 1307 1316 (Pubitemid 41735195)
    • (2005) Arthroscopy - Journal of Arthroscopic and Related Surgery , vol.21 , Issue.11 , pp. 1307-1316
    • Sugaya, H.1    Maeda, K.2    Matsuki, K.3    Moriishi, J.4
  • 37
    • 44449102556 scopus 로고    scopus 로고
    • Transosseous arthroscopic repair of partial articular-surface supraspinatus tendon tears
    • M. Tauber, H. Koller, and H. Resch Transosseous arthroscopic repair of partial articular-surface supraspinatus tendon tears Knee Surg. Sports Traumatol. Arthrosc. 16 2008 608 613
    • (2008) Knee Surg. Sports Traumatol. Arthrosc. , vol.16 , pp. 608-613
    • Tauber, M.1    Koller, H.2    Resch, H.3
  • 39
    • 0025731903 scopus 로고
    • The effect of arm position and capsular release on rotator cuff repair. A biomechanical study
    • J.D. Zuckerman, J.M. Leblanc, J. Choueka, and F. Kummer The effect of arm position and capsular release on rotator cuff repair. A biomechanical study J. Bone Joint Surg. Br. 73 1991 402 405
    • (1991) J. Bone Joint Surg. Br. , vol.73 , pp. 402-405
    • Zuckerman, J.D.1    Leblanc, J.M.2    Choueka, J.3    Kummer, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.