FRT capability of direct power controlled converters connected by an actively damped LCL-filter for wind power applications

Author keywords

active damping; direct power control; Fault ride through; three phase system

Indexed keywords

ACTIVE DAMPING; CONTROL METHODS; DIRECT POWER CONTROL; DYNAMIC PERFORMANCE; FAULT RIDE-THROUGH; GRID CODES; GRID-CONNECTED; LCL FILTERS; POWER APPLICATIONS; POWER CONTROLLED; SIMULATION AND MEASUREMENT; THREE PHASE SYSTEM; VOLTAGE SOURCE CONVERTERS;

EID: 80053521973     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (10)

References (16)
  • 4
    • 11144357249 scopus 로고    scopus 로고
    • Simple direct power control of three-phase PWM rectifier using space-vector modulation (DPC-SVM)
    • M. Malinowski, M. Jasinski, and K. M.P., "Simple direct power control of three-phase PWM rectifier using space-vector modulation (DPC-SVM)," IEEE Transactions on Industrial Electronics, vol. 51, no. 2, pp. 447-454, 2004.
    • (2004) IEEE Transactions on Industrial Electronics , vol.51 , Issue.2 , pp. 447-454
    • Malinowski, M.1    Jasinski, M.2    P, K.M.3
  • 5
    • 0032073781 scopus 로고    scopus 로고
    • Direct power control of PWM converter without power-source voltage sensors
    • PII S0093999498038808
    • T. Noguchi, H. Tomiki, S. Kondo, and I. Takahasli, "Direct Power Control of PWM Converter without powersource voltage sensors," IEEE Transaction on Industry Applications, vol. 34, no. 3, pp. 473-479, 1998. (Pubitemid 128740176)
    • (1998) IEEE Transactions on Industry Applications , vol.34 , Issue.3 , pp. 473-479
    • Noguchi, T.1    Tomiki, H.2    Kondo, S.3    Takahashi, I.4
  • 8
    • 60449091304 scopus 로고    scopus 로고
    • Limitations of Voltage-Oriented PI Current Control of Grid- Connected PWM Rectifiers with LCL Filters
    • Feb.
    • C. Wessels, J. Dannehl, and F. W. Fuchs, "Limitations of Voltage-Oriented PI Current Control of Grid- Connected PWM Rectifiers With LCL Filters," IEEE Transactions on Industrial Electronics, vol. 56, no. 2, pp. 380-388, Feb. 2009.
    • (2009) IEEE Transactions on Industrial Electronics , vol.56 , Issue.2 , pp. 380-388
    • Wessels, C.1    Dannehl, J.2    Fuchs, F.W.3
  • 9
    • 26844497165 scopus 로고    scopus 로고
    • Design and control of an LCL-filter-based three-phase active rectifier
    • DOI 10.1109/TIA.2005.853373
    • M. Liserre, F. Blaabjerg, and S. Hansen, "Design and Control of an LCL-Filter-Based Three-Phase Active Rectifier," IEEE Transaction on Industry Applications, vol. 41, no. 5, pp. 1281-1291, 2005. (Pubitemid 41444646)
    • (2005) IEEE Transactions on Industry Applications , vol.41 , Issue.5 , pp. 1281-1291
    • Liserre, M.1    Blaabjerg, F.2    Hansen, S.3
  • 10
    • 0031100327 scopus 로고    scopus 로고
    • A Novel Control to Actively Damp Resonance in Input LC Filter of a Three-Phase Voltage Source Inverter
    • V. Blasko and V. Kaura, "A Novel Control to Actively Damp Resonance in Input LC Filter of a Three-Phase Voltage Source Inverter," IEEE Transactions on Industry Applications, 1997.
    • (1997) IEEE Transactions on Industry Applications
    • Blasko, V.1    Kaura, V.2
  • 12
    • 35348885574 scopus 로고    scopus 로고
    • A modified direct power control strategy allowing the connection of three-phase inverters to the grid through LCL filters
    • DOI 10.1109/TIA.2007.904438
    • L. A. Serpa, S. Ponnaluri, P. M. Barbosa, and J. W. Kolar, "A Modified Direct Power Control Strategy Allowing the Connection of Three-Phase Inverters to the Grid Through LCL Filters," IEEE Transactions on Industry Applications, vol. 43, no. 5, pp. 1388-1400, 2007. (Pubitemid 47570239)
    • (2007) IEEE Transactions on Industry Applications , vol.43 , Issue.5 , pp. 1388-1400
    • Serpa, L.A.1    Ponnaluri, S.2    Barbosa, P.M.3    Kolar, J.W.4
  • 14
    • 0021429788 scopus 로고
    • Instantaneous Reactive Power Comensators Comprising Switching Devices without Enegery Storage Components
    • H. Akagi, Y. Kanazawa, and A. Nabae, "Instantaneous Reactive Power Comensators Comprising Switching Devices without Enegery Storage Components," IEEE Transaction on Industry Applications, vol. 20, no. 3, pp. 625-629, 1984.
    • (1984) IEEE Transaction on Industry Applications , vol.20 , Issue.3 , pp. 625-629
    • Akagi, H.1    Kanazawa, Y.2    Nabae, A.3
  • 15
    • 42449090236 scopus 로고    scopus 로고
    • New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions
    • P. Rodriguez, et al., "New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions," in Power Electronics Specialists Conference, PESC '06, 2006.
    • Power Electronics Specialists Conference, PESC '06, 2006
    • Rodriguez, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.