메뉴 건너뛰기




Volumn 47, Issue 10, 2011, Pages 3070-3073

Measurement of spontaneous oscillatory magnetic field of guinea-pig smooth muscle preparation using pico-tesla resolution amorphous wire magneto-impedance sensor

Author keywords

Amorphous magnetic materials; cell; magnetic sensors; magneto impedance; tissue engineering

Indexed keywords

CELL ENGINEERING; CELLS; MAGNETIC FIELD MEASUREMENT; MAGNETIC FIELDS; MAGNETIC MATERIALS; MAGNETIC SENSORS; MAMMALS; STEM CELLS; TISSUE ENGINEERING;

EID: 80053503123     PISSN: 00189464     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMAG.2011.2148165     Document Type: Article
Times cited : (126)

References (9)
  • 1
    • 20644454099 scopus 로고
    • Magneto-impedance effect in amorphous wires
    • L. V. Panina and K. Mohri, "Magneto-impedance effect in amorphous wires," Appl. Phys. Lett., vol. 65, no. 9, pp. 1189-1191, 1994.
    • (1994) Appl. Phys. Lett. , vol.65 , Issue.9 , pp. 1189-1191
    • Panina, L.V.1    Mohri, K.2
  • 2
    • 34248531866 scopus 로고    scopus 로고
    • Amorphous wire andCMOSIC based magneto- impedance sensors-Origin, topics and future
    • K. Mohri and Y. Honkura, "Amorphous wire andCMOSIC based magneto- impedance sensors-Origin, topics and future," Sensor Lett., vol. 5, pp. 267-270, 2007.
    • (2007) Sensor Lett. , vol.5 , pp. 267-270
    • Mohri, K.1    Honkura, Y.2
  • 3
    • 65649128557 scopus 로고    scopus 로고
    • Biomagnetic field detection using very high sensitivity magneto-impedance sensors for medical applications
    • T. Uchiyama, S. Nakayama, K. Mohri, and K. Bushida, "Biomagnetic field detection using very high sensitivity magneto-impedance sensors for medical applications," Phys. Stat. Solidi A, vol. 206, no. 4, pp. 639-643, 2009.
    • (2009) Phys. Stat. Solidi A , vol.206 , Issue.4 , pp. 639-643
    • Uchiyama, T.1    Nakayama, S.2    Mohri, K.3    Bushida, K.4
  • 4
    • 39349090635 scopus 로고    scopus 로고
    • Optimization of the magnetic noise and sensitivity of giant magnetoimpedance sensors
    • L. G. C. Melo, D. Menard, A. Yelon, L. Ding, S. Saez, and C. Dolabdjian, "Optimization of the magnetic noise and sensitivity of giant magnetoimpedance sensors," J. Appl. Phys., vol. 103, pp. 033903-1-03303-6, 2008.
    • (2008) J. Appl. Phys. , vol.103 , pp. 0339031-0033036
    • Melo, L.G.C.1    Menard, D.2    Yelon, A.3    Ding, L.4    Saez, S.5    Dolabdjian, C.6
  • 5
    • 9744227965 scopus 로고    scopus 로고
    • Off-diagonal impedance in amorphous wires and its application to linear magnetic sensors
    • S. Sandacci, D. Makhnovskiy, L. Panina, K. Mohri, and Y. Honkura, "Off-diagonal impedance in amorphous wires and its application to linear magnetic sensors," IEEE Trans. Magn., vol. 40, no. 6, pp. 18-23, 2008.
    • (2008) IEEE Trans. Magn. , vol.40 , Issue.6 , pp. 18-23
    • Sandacci, S.1    Makhnovskiy, D.2    Panina, L.3    Mohri, K.4    Honkura, Y.5
  • 6
    • 0033184446 scopus 로고    scopus 로고
    • Highly stable MI micro sensor using CMOS IC multivibrator with synchronous rectification
    • N. Kawajiri, M. Nakabayashi, C. M. Cai, K. Mohri, and T. Uchiyama, "Highly stable MI micro sensor using CMOS IC multivibrator with synchronous rectification," IEEE Trans. Magn., vol. 35, no. 5, pp. 3667-3669, 1999.
    • (1999) IEEE Trans. Magn. , vol.35 , Issue.5 , pp. 3667-3669
    • Kawajiri, N.1    Nakabayashi, M.2    Cai, C.M.3    Mohri, K.4    Uchiyama, T.5
  • 7
    • 33750411905 scopus 로고    scopus 로고
    • Pacemaker phase shift in the absence of neural activity in guinea-pig stomach: A microelectrode array study
    • S. Nakayama, K. Shimono, H.-N. Liu, H. Jiko, N. Katayama, T. Tomita, and K. Goto, "Pacemaker phase shift in the absence of neural activity in guinea-pig stomach: A microelectrode array study," J. Physiol., vol. 576, pp. 727-738, 2006.
    • (2006) J. Physiol. , vol.576 , pp. 727-738
    • Nakayama, S.1    Shimono, K.2    Liu, H.N.3    Jiko, H.4    Katayama, N.5    Tomita, T.6    Goto, K.7
  • 8
    • 23144439382 scopus 로고    scopus 로고
    • Action potential refractory period in ureter smooth muscle is set by Ca sparks and BK channels
    • T. Burdua and S. Wray, "Action potential refractory period in ureter smooth muscle is set by Ca sparks and BK channels," Nature, vol. 436, pp. 559-562, 2005.
    • (2005) Nature , vol.436 , pp. 559-562
    • Burdua, T.1    Wray, S.2
  • 9
    • 0016753746 scopus 로고
    • Effect of stimulating the acetylcholine receptor on the current-Voltage relationship of the smooth muscle membrane studied by voltage clamp of potential recorded by micro-electrode
    • T. B. Bolton, "Effect of stimulating the acetylcholine receptor on the current-Voltage relationship of the smooth muscle membrane studied by voltage clamp of potential recorded by micro-electrode," J. Physiol., vol. 250, pp. 175-202, 1975.
    • (1975) J. Physiol , vol.250 , pp. 175-202
    • Bolton, T.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.