메뉴 건너뛰기




Volumn 50, Issue 28, 2011, Pages 5592-5599

Stand-off detection of explosives particles by multispectral imaging Raman spectroscopy

Author keywords

[No Author keywords available]

Indexed keywords

CHARGE COUPLED DEVICES; EXPLOSIVES; IMAGING TECHNIQUES; LIQUID CRYSTALS; NEODYMIUM LASERS; RAMAN SPECTROSCOPY; SIGNAL RECEIVERS; SULFUR; TELESCOPES;

EID: 80053404678     PISSN: 1559128X     EISSN: 15394522     Source Type: Journal    
DOI: 10.1364/AO.50.005592     Document Type: Article
Times cited : (61)

References (20)
  • 2
    • 68949221580 scopus 로고    scopus 로고
    • Laserbased standoff detection of explosives: A critical review
    • S. Wallin, A. Pettersson, H. Östmark, and A. Hobro, "Laserbased standoff detection of explosives: a critical review," Anal. Bioanal. Chem. 395, 259-274 (2009).
    • (2009) Anal. Bioanal. Chem. , vol.395 , pp. 259-274
    • Wallin, S.1    Pettersson, A.2    Östmark, H.3    Hobro, A.4
  • 3
    • 68949212291 scopus 로고    scopus 로고
    • Laser-induced breakdown spectroscopy for detection of explosives residues: A review of recent advances, challenges, and future prospects
    • J. L. Gottfried, F. C. De Lucia, C. A. Munson, and A. W. Miziolek, "Laser-induced breakdown spectroscopy for detection of explosives residues: a review of recent advances, challenges, and future prospects," Anal. Bioanal. Chem. 395, 283-300 (2009).
    • (2009) Anal. Bioanal. Chem. , vol.395 , pp. 283-300
    • Gottfried, J.L.1    De Lucia, F.C.2    Munson, C.A.3    Miziolek, A.W.4
  • 4
    • 22344451355 scopus 로고    scopus 로고
    • Portable remote Raman system for monitoring hydrocarbon, gas hydrates and explosives in the environment
    • DOI 10.1016/j.saa.2005.02.020, PII S1386142505000685, Georaman 2004: Sixth International Conference on Raman Spectroscopy Applies to the Earth and Planetary Sciences
    • S. K. Sharma, A. K. Mistra, and B. Sharma, "Portable remote Raman system for monitoring hydrocarbon, gas hydrates and explosives in the environment," Spectrochim. Acta A 61, 2404-2412 (2005). (Pubitemid 41000363)
    • (2005) Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy , vol.61 , Issue.10 , pp. 2404-2412
    • Sharma, S.K.1    Misra, A.K.2    Sharma, B.3
  • 5
    • 21244454031 scopus 로고    scopus 로고
    • Standoff detection of high explosive materials at 50 meters in ambient light conditions using a small Raman instrument
    • DOI 10.1366/0003702054280612
    • J. C. Carter, S. M. Angel, M. Lawrence-Snyder, J. Scaffidi, R. E. Whipple, and J. G. Reynolds, "Standoff detection of high explosive materials at 50 meters in ambient light conditions using a smallRamaninstrument, " Appl. Spectrosc.59, 769-775(2005). (Pubitemid 40891140)
    • (2005) Applied Spectroscopy , vol.59 , Issue.6 , pp. 769-775
    • Carter, J.C.1    Angel, S.M.2    Lawrence-Snyder, M.3    Scaffidi, J.4    Whipple, R.E.5    Reynolds, J.G.6
  • 8
    • 37049103334 scopus 로고
    • Vapour pressure measurements on some organic high explosives
    • R. B. Cundall, T. F. Palmer, and C. E. C. Wood, "Vapour pressure measurements on some organic high explosives," J. Chem. Soc. Faraday Trans. I 74, 1339-1345 (1978).
    • (1978) J. Chem. Soc. Faraday Trans. I , vol.74 , pp. 1339-1345
    • Cundall, R.B.1    Palmer, T.F.2    Wood, C.E.C.3
  • 9
    • 68949205733 scopus 로고    scopus 로고
    • Measurement of trace explosive residues in a surrogate operational environment: Implications for tactical use of chemical sensing in C-IED operations
    • R. R. Kunz, K. C. Gregory, D. Hardy, J. Oyler, S. A. Ostazeski, and A. W. Fountain, III, "Measurement of trace explosive residues in a surrogate operational environment: implications for tactical use of chemical sensing in C-IED operations," Anal. Bioanal. Chem. 395, 357-369 (2009).
    • (2009) Anal. Bioanal. Chem. , vol.395 , pp. 357-369
    • Kunz, R.R.1    Gregory, K.C.2    Hardy, D.3    Oyler, J.4    Ostazeski, S.A.5    Fountain Iii, A.W.6
  • 10
    • 77649269078 scopus 로고
    • Development of particle standards for testing detection systems: Mass of RDX and particle size distribution of composition 4 residues
    • G. L. Gresham, J. P. Davies, L. D. Goodrich, L. G. Blackwood, B. Y. Liu, D. Thimsen, S. H. Yoo, and S. F. Hallowell, "Development of particle standards for testing detection systems: mass of RDX and particle size distribution of composition 4 residues," Proc. SPIE 2276, 34-44 (1994).
    • (1994) Proc. SPIE , vol.2276 , pp. 34-44
    • Gresham, G.L.1    Davies, J.P.2    Goodrich, L.D.3    Blackwood, L.G.4    Liu, B.Y.5    Thimsen, D.6    Yoo, S.H.7    Hallowell, S.F.8
  • 12
    • 44649144494 scopus 로고    scopus 로고
    • UV gated Raman spectroscopy for standoff detection of explosives
    • M. Gaft and L. Nagli, "UV gated Raman spectroscopy for standoff detection of explosives," Opt. Mater. 30, 1739-1746 (2008).
    • (2008) Opt. Mater. , vol.30 , pp. 1739-1746
    • Gaft, M.1    Nagli, L.2
  • 13
    • 44649090220 scopus 로고    scopus 로고
    • Absolute Raman cross-sections of some explosives: Trend to UV
    • L. Naglia, M. Gaft, Y. Fleger, and M. Rosenbluh, "Absolute Raman cross-sections of some explosives: trend to UV," Opt. Mater. 30, 1747-1754 (2008).
    • (2008) Opt. Mater. , vol.30 , pp. 1747-1754
    • Naglia, L.1    Gaft, M.2    Fleger, Y.3    Rosenbluh, M.4
  • 14
    • 68949187632 scopus 로고    scopus 로고
    • Near real-time standoff detection of explosives in a realistic outdoor environment at 55m distance
    • A. Pettersson, I. Johansson, S. Wallin, M. Nordberg, and H. Östmark, "Near real-time standoff detection of explosives in a realistic outdoor environment at 55m distance," Propellants Explos. Pyrotech. 34, 297-306 (2009).
    • (2009) Propellants Explos. Pyrotech. , vol.34 , pp. 297-306
    • Pettersson, A.1    Johansson, I.2    Wallin, S.3    Nordberg, H.4    Östmark, M.5
  • 17
    • 33847169511 scopus 로고    scopus 로고
    • Particle characteristics of trace high explosives: RDX and PETN
    • DOI 10.1111/j.1556-4029.2006.00354.x
    • J. R. Verkouteren, "Particle characteristics of trace high explosives: RDX and PETN," J. Forensic Sci. 52, 335-340 (2007). (Pubitemid 46280518)
    • (2007) Journal of Forensic Sciences , vol.52 , Issue.2 , pp. 335-340
    • Verkouteren, J.R.1
  • 19
    • 84893886319 scopus 로고    scopus 로고
    • 23 April 2011
    • http://chemimage.com/markets/threat-detection/explosive/index.aspx, 23 April 2011.
  • 20
    • 33846261521 scopus 로고    scopus 로고
    • Evaluation of a high throughput liquid crystal tunable filter for Raman chemical imaging of threat materials
    • X. Wang, T. C. Voigt, P. J. Bos, M. P. Nelson, and P. J. Treado, "Evaluation of a high throughput liquid crystal tunable filter for Raman chemical imaging of threat materials," Proc. SPIE 6378, 637808 (2006).
    • (2006) Proc. SPIE , vol.6378 , pp. 637808
    • Wang, X.1    Voigt, T.C.2    Bos, P.J.3    Nelson, M.P.4    Treado, P.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.