메뉴 건너뛰기




Volumn 53, Issue 1, 2012, Pages 240-246

Area ratio effects to the performance of air-cooled ejector refrigeration cycle with R134a refrigerant

Author keywords

Air cooled condenser; Area ratio; Coefficient of performance; Cooling capacity; Ejector refrigeration cycle; Entrainment ratio

Indexed keywords

AIR-COOLED CONDENSERS; AREA RATIOS; COEFFICIENT OF PERFORMANCE; COOLING CAPACITY; EJECTOR REFRIGERATION CYCLE; ENTRAINMENT RATIO;

EID: 80053363874     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2011.09.002     Document Type: Article
Times cited : (117)

References (27)
  • 1
    • 34547106043 scopus 로고    scopus 로고
    • Shock circle model for ejector performance evaluation
    • Y.H. Zhu, W.J. Cai, C.Y. Wen, and Y.Z. Li Shock circle model for ejector performance evaluation Energy Convers Manage 48 2007 2533 2541
    • (2007) Energy Convers Manage , vol.48 , pp. 2533-2541
    • Zhu, Y.H.1    Cai, W.J.2    Wen, C.Y.3    Li, Y.Z.4
  • 2
    • 77951208539 scopus 로고    scopus 로고
    • Development of hybrid solar-assisted cooling/heating system
    • B.J. Huang, J.H. Wu, H.Y. Hsu, and J.H. Wang Development of hybrid solar-assisted cooling/heating system Energy Convers Manage 51 2010 1643 1650
    • (2010) Energy Convers Manage , vol.51 , pp. 1643-1650
    • Huang, B.J.1    Wu, J.H.2    Hsu, H.Y.3    Wang, J.H.4
  • 3
    • 0033133417 scopus 로고    scopus 로고
    • Comparative study of the performance of an ejector refrigeration cycle operating with various refrigerants
    • D.W. Sun Comparative study of the performance of an ejector refrigeration cycle operating with various refrigerants Energy Convers Manage 40 1999 873 884
    • (1999) Energy Convers Manage , vol.40 , pp. 873-884
    • Sun, D.W.1
  • 4
    • 0000234086 scopus 로고    scopus 로고
    • Solar powered combined ejector-vapour compression cycle for air conditioning and refrigeration
    • D.W. Sun Solar powered combined ejector-vapour compression cycle for air conditioning and refrigeration Energy Convers Manage 38 1997 479 491
    • (1997) Energy Convers Manage , vol.38 , pp. 479-491
    • Sun, D.W.1
  • 5
    • 4344715585 scopus 로고    scopus 로고
    • Estimation of ejector's main cross sections in steam-ejector refrigeration system
    • G.K. Alexis Estimation of ejector's main cross sections in steam-ejector refrigeration system Appl Therm Eng 24 2004 2657 2663
    • (2004) Appl Therm Eng , vol.24 , pp. 2657-2663
    • Alexis, G.K.1
  • 6
    • 33847104171 scopus 로고    scopus 로고
    • A theoretical study of a novel regenerative ejector refrigeration cycle
    • J.L. Yu, and Y.Z. Li A theoretical study of a novel regenerative ejector refrigeration cycle Int J Refrig 30 2007 464 470
    • (2007) Int J Refrig , vol.30 , pp. 464-470
    • Yu, J.L.1    Li, Y.Z.2
  • 7
    • 0001106190 scopus 로고    scopus 로고
    • Development of a solar-powered passive ejector cooling system
    • DOI 10.1016/S1359-4311(00)00032-6, PII S1359431100000326
    • V.M. Nguyen, S.B. Riffat, and P.S. Doherty Development of a solar-powered passive ejector cooling system Appl Therm Eng 21 2001 157 168 (Pubitemid 33648346)
    • (2001) Applied Thermal Engineering , vol.21 , Issue.2 , pp. 157-168
    • Nguyen, V.M.1    Riffat, S.B.2    Doherty, P.S.3
  • 8
    • 62849089650 scopus 로고    scopus 로고
    • Performance of ejector cooling system with thermal pumping effect using R141b and R365mfc
    • J.H. Wang, J.H. Wu, S.S. Hu, and B.J. Huang Performance of ejector cooling system with thermal pumping effect using R141b and R365mfc Appl Therm Eng 29 2009 1904 1912
    • (2009) Appl Therm Eng , vol.29 , pp. 1904-1912
    • Wang, J.H.1    Wu, J.H.2    Hu, S.S.3    Huang, B.J.4
  • 9
    • 28244492800 scopus 로고    scopus 로고
    • Numerical assessment of ejector operation for refrigeration applications based on CFD
    • DOI 10.1016/j.applthermaleng.2005.07.003, PII S1359431105002206
    • Y. Bartosiewicz, Z. Aidoun, and Y. Mercadier Numerical assessment of ejector operation for refrigeration applications based on CFD Appl Therm Eng 26 2006 604 612 (Pubitemid 41706318)
    • (2006) Applied Thermal Engineering , vol.26 , Issue.5-6 , pp. 604-612
    • Bartosiewicz, Y.1    Aidoun, Z.2    Mercadier, Y.3
  • 10
    • 33847089026 scopus 로고
    • A new ejector theory applied to steam jet refrigeration
    • J.T. Munday, and D.F. Bagster A new ejector theory applied to steam jet refrigeration Ind Eng Chem Process Des Dev 16 1977 442 449
    • (1977) Ind Eng Chem Process des Dev , vol.16 , pp. 442-449
    • Munday, J.T.1    Bagster, D.F.2
  • 12
    • 85137259689 scopus 로고
    • An investigation of ejector design by analysis and experiment
    • J.H. Keenan, E.P. Neumann, and F. Lustwerk An investigation of ejector design by analysis and experiment J Appl Mech Trans ASME 72 1950 299 309
    • (1950) J Appl Mech Trans ASME , vol.72 , pp. 299-309
    • Keenan, J.H.1    Neumann, E.P.2    Lustwerk, F.3
  • 13
    • 69749114052 scopus 로고    scopus 로고
    • Influence of geometrical factors on steam ejector performance - A numerical assessment
    • S. Varga, A.C. Oliveira, and B. Diaconu Influence of geometrical factors on steam ejector performance - A numerical assessment Int J Refrig 32 2009 1694 1701
    • (2009) Int J Refrig , vol.32 , pp. 1694-1701
    • Varga, S.1    Oliveira, A.C.2    Diaconu, B.3
  • 14
    • 77951098476 scopus 로고    scopus 로고
    • Experimental investigation of a novel steam ejector refrigerator suitable for solar energy applications
    • X.L. Ma, W. Zhang, S.A. Omer, and S.B. Riffat Experimental investigation of a novel steam ejector refrigerator suitable for solar energy applications Appl Therm Eng 30 2010 1320 1325
    • (2010) Appl Therm Eng , vol.30 , pp. 1320-1325
    • Ma, X.L.1    Zhang, W.2    Omer, S.A.3    Riffat, S.B.4
  • 15
    • 51249098525 scopus 로고    scopus 로고
    • Experimental determination of the optimum performance of ejector refrigeration system depending on ejector area ratio
    • R. Yapici Experimental determination of the optimum performance of ejector refrigeration system depending on ejector area ratio Int J Refrig 31 2008 1183 1189
    • (2008) Int J Refrig , vol.31 , pp. 1183-1189
    • Yapici, R.1
  • 16
    • 34548082048 scopus 로고    scopus 로고
    • Results of an experimental study of an advanced jet-pump refrigerator operating with R245fa
    • DOI 10.1016/j.applthermaleng.2006.12.009, PII S135943110600425X
    • I.W. Eames, A.E. Ablwaifa, and V. Petrenko Results of an experimental study of an advanced jet-pump refrigerator operating with R245fa Appl Therm Eng 27 2007 2833 2840 (Pubitemid 47296382)
    • (2007) Applied Thermal Engineering , vol.27 , Issue.17-18 , pp. 2833-2840
    • Eames, I.W.1    Ablwaifa, A.E.2    Petrenko, V.3
  • 17
    • 33748035736 scopus 로고    scopus 로고
    • Experimental investigation on R134a vapour ejector refrigeration system
    • DOI 10.1016/j.ijrefrig.2006.01.004, PII S0140700706000326
    • A. Selvaraju, and A. Mani Experimental investigation on R134a vapour ejector refrigeration system Int J Refrig 29 2006 1160 1166 (Pubitemid 44301474)
    • (2006) International Journal of Refrigeration , vol.29 , Issue.7 , pp. 1160-1166
    • Selvaraju, A.1    Mani, A.2
  • 18
    • 80655142237 scopus 로고    scopus 로고
    • Use of variable geometry ejector with cold store to achieve high solar fraction for solar cooling
    • M. Dennis, and K. Garzoli Use of variable geometry ejector with cold store to achieve high solar fraction for solar cooling Int J Refrig XXX 2010 1 7
    • (2010) Int J Refrig , vol.30 , pp. 1-7
    • Dennis, M.1    Garzoli, K.2
  • 19
    • 0030266401 scopus 로고    scopus 로고
    • Variable geometry ejectors and their applications
    • D.W. Sun Variable geometry ejectors and their applications Energy 21 1996 919 929
    • (1996) Energy , vol.21 , pp. 919-929
    • Sun, D.W.1
  • 20
    • 0242573455 scopus 로고    scopus 로고
    • An experimental investigation of a steam ejector refrigerator: The analysis of the pressure profile along the ejector
    • K. Chunnanond, and S. Aphornratana An experimental investigation of a steam ejector refrigerator: the analysis of the pressure profile along the ejector Appl Therm Eng 27 2004 311 322
    • (2004) Appl Therm Eng , vol.27 , pp. 311-322
    • Chunnanond, K.1    Aphornratana, S.2
  • 21
    • 58549099469 scopus 로고    scopus 로고
    • Numerical investigation of geometry parameters for design of high performance ejectors
    • Y.H. Zhu, W.J. Cai, C.Y. Wen, and Y.Z. Li Numerical investigation of geometry parameters for design of high performance ejectors Appl Therm Eng 29 2009 898 905
    • (2009) Appl Therm Eng , vol.29 , pp. 898-905
    • Zhu, Y.H.1    Cai, W.J.2    Wen, C.Y.3    Li, Y.Z.4
  • 24
    • 0032647818 scopus 로고    scopus 로고
    • Empirical correlation for ejector design
    • B.J. Huang, and J.M. Chang Empirical correlation for ejector design Int J Refrig 22 1999 379 388
    • (1999) Int J Refrig , vol.22 , pp. 379-388
    • Huang, B.J.1    Chang, J.M.2
  • 26
    • 0342400746 scopus 로고
    • ASHRAE. Steam-jet refrigeration equipment
    • ASHRAE. Steam-jet refrigeration equipment. vol. 13. Equipment Handbook; 1979. p. 13.1-6.
    • (1979) Equipment Handbook , vol.13 , pp. 131-136
  • 27
    • 34848824374 scopus 로고    scopus 로고
    • Fuel ejector design and simulation model for anodic recirculation SOFC system
    • Y.H. Zhu, W.J. Cai, C.Y. Wen, and Y.Z. Li Fuel ejector design and simulation model for anodic recirculation SOFC system J Power Sources 173 2007 437 449
    • (2007) J Power Sources , vol.173 , pp. 437-449
    • Zhu, Y.H.1    Cai, W.J.2    Wen, C.Y.3    Li, Y.Z.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.