메뉴 건너뛰기




Volumn 52, Issue 8, 2011, Pages 5862-5871

Automatic detection of diabetic retinopathy and age-related macular degeneration in digital fundus images

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ALGORITHM; ARTICLE; BLEEDING; CHILD; CLASSIFICATION ALGORITHM; DATA BASE; DIABETIC RETINOPATHY; DIAGNOSTIC TEST ACCURACY STUDY; DRUSEN; EXUDATE; FEMALE; GEOGRAPHIC ATROPHY; HUMAN; IMAGE PROCESSING; INFANT; MAJOR CLINICAL STUDY; MALE; MICROANEURYSM; MULTICENTER STUDY; NEOVASCULARIZATION (PATHOLOGY); NEWBORN; OPTIC DISK; PIGMENT DISORDER; PRESCHOOL CHILD; PRIORITY JOURNAL; RETINA MACULA AGE RELATED DEGENERATION; RETINA MACULA EDEMA; RETINA MACULA LUTEA; RETROSPECTIVE STUDY; SCHOOL CHILD; BIOLOGICAL MODEL; CLINICAL TRIAL; FLUORESCENCE ANGIOGRAPHY; METHODOLOGY; MIDDLE AGED; OBSERVER VARIATION; PATHOLOGY; RECEIVER OPERATING CHARACTERISTIC; REPRODUCIBILITY; RETINA MACULA DEGENERATION; STANDARD; STATISTICS; VALIDATION STUDY;

EID: 80053326482     PISSN: 01460404     EISSN: 15525783     Source Type: Journal    
DOI: 10.1167/iovs.10-7075     Document Type: Article
Times cited : (91)

References (24)
  • 1
    • 77955376918 scopus 로고    scopus 로고
    • Prevalence of diabetic Retinopathy in the United States 2005-2008
    • Zhang X, Saaddine JB, Chou CF, et al. Prevalence of diabetic Retinopathy in the United States 2005-2008. JAMA. 2010;304(6): 649-656.
    • (2010) JAMA. , vol.304 , Issue.6 , pp. 649-656
    • Zhang, X.1    Saaddine, J.B.2    Chou, C.F.3
  • 2
    • 11144354339 scopus 로고    scopus 로고
    • Prevalence of agerelated macular degeneration in the United States
    • The Eye Diseases Prevalence Research Group
    • The Eye Diseases Prevalence Research Group. Prevalence of agerelated macular degeneration in the United States. Arch Ophthalmol. 2004;122:564-572.
    • (2004) Arch Ophthalmol. , vol.122 , pp. 564-572
  • 3
    • 77953776184 scopus 로고    scopus 로고
    • Costs and consequences of automated algorithms versus manual grading for the detection of referable diabetic retinopathy
    • Scotland GS, McNamee P, Fleming AD, et al. Costs and consequences of automated algorithms versus manual grading for the detection of referable diabetic retinopathy. Br J Ophthalmol. 2010;94:712-719.
    • (2010) Br J Ophthalmol. , vol.94 , pp. 712-719
    • Scotland, G.S.1    McNamee, P.2    Fleming, A.D.3
  • 4
    • 0025845943 scopus 로고
    • Grading diabetic retinopathy from stereoscopic color fundus photographs: An extension of the modified Airlie House classification
    • Early Treatment Diabetic Retinopathy Study Research Group
    • Early Treatment Diabetic Retinopathy Study Research Group. Grading diabetic retinopathy from stereoscopic color fundus photographs: an extension of the modified Airlie House classification. ETDRS report 10. 1991;98:786-806.
    • (1991) ETDRS report 10. , vol.98 , pp. 786-806
  • 5
    • 78650176876 scopus 로고    scopus 로고
    • Digital versus film fundus photography for research grading of diabetic retinopathy severity
    • Li HK, Hubbard LD, Danis RP. Digital versus film fundus photography for research grading of diabetic retinopathy severity. Invest Ophthalmol Vis Sci. 2010;51:5846-5852.
    • (2010) Invest Ophthalmol Vis Sci. , vol.51 , pp. 5846-5852
    • Li, H.K.1    Hubbard, L.D.2    Danis, R.P.3
  • 6
    • 0038460765 scopus 로고    scopus 로고
    • The effectiveness of screening for diabetic retinopathy by digital imaging photography and technician ophthalmoscopy
    • Scanlon PH, Malhotra R, Thomas G. The effectiveness of screening for diabetic retinopathy by digital imaging photography and technician ophthalmoscopy. Diabet Med. 2003;20(6):467-474.
    • (2003) Diabet Med. , vol.20 , Issue.6 , pp. 467-474
    • Scanlon, P.H.1    Malhotra, R.2    Thomas, G.3
  • 7
    • 0037308615 scopus 로고    scopus 로고
    • Automated detection of diabetic retinopathy in a fundus photographic screening population
    • Larsen N, Godt J, Grunkin M, Lund. Andersen H, Larsen M. Automated detection of diabetic retinopathy in a fundus photographic screening population. Invest Ophthalmol Vis Sci. 2003; 44(2):767-71.
    • (2003) Invest Ophthalmol Vis Sci. , vol.44 , Issue.2 , pp. 767-771
    • Larsen, N.1    Godt, J.2    Grunkin, M.3    Lund. Andersen, H.4    Larsen, M.5
  • 8
    • 65549099337 scopus 로고    scopus 로고
    • Information fusion for diabetic retinopathy CAD in digital color fundus photographs
    • Niemeijer M, Abràmoff MD, van Ginneken B. Information fusion for diabetic retinopathy CAD in digital color fundus photographs. IEEE Transactions on Medical Imaging. 2009;28(5)775-785.
    • (2009) IEEE Transactions on Medical Imaging , vol.28 , Issue.5 , pp. 775-785
    • Niemeijer, M.1    Abràmoff, M.D.2    van Ginneken, B.3
  • 10
    • 78649881507 scopus 로고    scopus 로고
    • Automated grading for diabetic retinopathy: A large-scale audit using arbitration by clinical experts
    • Fleming AD, Goatman KA, Philip S, Prescott GJ, Sharp PF, Olson JA. Automated grading for diabetic retinopathy: a large-scale audit using arbitration by clinical experts. Br J Ophthalmol. 2010;94: 1606-1610.
    • (2010) Br J Ophthalmol. , vol.94 , pp. 1606-1610
    • Fleming, A.D.1    Goatman, K.A.2    Philip, S.3    Prescott, G.J.4    Sharp, P.F.5    Olson, J.A.6
  • 11
    • 76249116685 scopus 로고    scopus 로고
    • Multiscale AM-FM methods for diabetic retinopathy lesion detection
    • Agurto C, Murray V, Barriga, et al. Multiscale AM-FM methods for diabetic retinopathy lesion detection. IEEE Trans Med Imag. 2010;29(2):502-512.
    • (2010) IEEE Trans Med Imag. , vol.29 , Issue.2 , pp. 502-512
    • Agurto, C.1    Murray, V.2    Barriga3
  • 12
    • 33645410077 scopus 로고    scopus 로고
    • Automated assessment of diabetic retinal Image quality based on clarity and field definition
    • Fleming AD, Philip S, Goatman K, Olson J, Sharp P. Automated assessment of diabetic retinal Image quality based on clarity and field definition. Invest Ophthalmol Vis Sci. 2006;47:1120-1125.
    • (2006) Invest Ophthalmol Vis Sci. , vol.47 , pp. 1120-1125
    • Fleming, A.D.1    Philip, S.2    Goatman, K.3    Olson, J.4    Sharp, P.5
  • 13
    • 77951279265 scopus 로고    scopus 로고
    • Multi-scale AM-FM Demodulation and reconstruction methods with improved accuracy
    • Murray V, Rodriguez P, Pattichis MS. Multi-scale AM-FM Demodulation and reconstruction methods with improved accuracy. IEEE Trans Image Process. 2010;19(5):1138-1152.
    • (2010) IEEE Trans Image Process. , vol.19 , Issue.5 , pp. 1138-1152
    • Murray, V.1    Rodriguez, P.2    Pattichis, M.S.3
  • 14
    • 70349697735 scopus 로고    scopus 로고
    • AM-FM Methods for Image and Video Processing
    • Albuquerque, NM: University of New Mexico
    • Murray-Herrera VM. AM-FM Methods for Image and Video Processing. PhD dissertation. Albuquerque, NM: University of New Mexico; 2008.
    • (2008) PhD dissertation
    • Murray-Herrera, V.M.1
  • 15
    • 0024307706 scopus 로고
    • Detection of diabetic macular edema: Ophthalmoscopy versus photography. Early Treatment Diabetic Retinopathy Study Report Number 5, The ETDRS Research Group
    • Kinyoun J, Barton F, Fisher M, Hubbard L, Aiello L, Ferris F. Detection of diabetic macular edema: ophthalmoscopy versus photography. Early Treatment Diabetic Retinopathy Study Report Number 5, The ETDRS Research Group. Ophthalmology. 1989;96: 746-750.
    • (1989) Ophthalmology. , vol.96 , pp. 746-750
    • Kinyoun, J.1    Barton, F.2    Fisher, M.3    Hubbard, L.4    Aiello, L.5    Ferris, F.6
  • 16
    • 33845398691 scopus 로고    scopus 로고
    • Monoscopic versus stereoscopic photography in screening for clinically significant macular edema
    • Welty CJ, Agarwal A, Merin LM, Chomsky A. Monoscopic versus stereoscopic photography in screening for clinically significant macular edema. Ophthalmic Surg Lasers Imaging. 2006;37:524-526.
    • (2006) Ophthalmic Surg Lasers Imaging. , vol.37 , pp. 524-526
    • Welty, C.J.1    Agarwal, A.2    Merin, L.M.3    Chomsky, A.4
  • 17
    • 33846309630 scopus 로고    scopus 로고
    • Benefits of stereopsis when identifying clinically significant macular edema via tele-ophthalmology
    • Rudnisky CJ, Tennant MT, de Leon AR, Hinz BJ, Greve MD. Benefits of stereopsis when identifying clinically significant macular edema via tele-ophthalmology. Can J Ophthalmol. 2006;41(6): 727-732.
    • (2006) Can J Ophthalmol. , vol.41 , Issue.6 , pp. 727-732
    • Rudnisky, C.J.1    Tennant, M.T.2    de Leon, A.R.3    Hinz, B.J.4    Greve, M.D.5
  • 19
    • 77949393746 scopus 로고    scopus 로고
    • Automated detection of diabetic retinopathy: Barriers to translation into clinical practice
    • Abràmoff MD, Niemeijer M, Russell SR. Automated detection of diabetic retinopathy: barriers to translation into clinical practice. Expert Rev Med Devices. 2010;7(2):287-296.
    • (2010) Expert Rev Med Devices. , vol.7 , Issue.2 , pp. 287-296
    • Abràmoff, M.D.1    Niemeijer, M.2    Russell, S.R.3
  • 20
    • 79955761255 scopus 로고    scopus 로고
    • Training variability in the evaluation of automated classifiers
    • Chen W, Gallas BD. Training variability in the evaluation of automated classifiers. Proc. SPIE 2010;7624:762404.
    • (2010) Proc. SPIE , vol.7624 , pp. 762404
    • Chen, W.1    Gallas, B.D.2
  • 21
    • 79955754320 scopus 로고    scopus 로고
    • Effects of image compression and degradation on an automated diabetic retinopathy screening algorithm
    • Agurto C, Barriga S, Murray V, Pattichis M, Davis B, Soliz P. Effects of image compression and degradation on an automated diabetic retinopathy screening algorithm. Proc. SPIE 2010;7624:76240H.
    • (2010) Proc. SPIE , vol.7624
    • Agurto, C.1    Barriga, S.2    Murray, V.3    Pattichis, M.4    Davis, B.5    Soliz, P.6
  • 22
    • 70349669130 scopus 로고    scopus 로고
    • Detection and phenotyping of retinal disease using AM-FM processing for feature extraction
    • Systems and Computers, October 26-29, Conference on
    • Agurto C, Murillo S, Murray V, et al. Detection and phenotyping of retinal disease using AM-FM processing for feature extraction. 42nd IEEE Asilomar Conference on Signals, Systems and Computers, October 26-29, 2008. 2008:659-663. Conference on.
    • (2008) 42nd IEEE Asilomar Conference on Signals , vol.2008 , pp. 659-663
    • Agurto, C.1    Murillo, S.2    Murray, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.