메뉴 건너뛰기




Volumn 43, Issue 11, 2011, Pages 3068-3073

A raw water source heat pump air-conditioning system

Author keywords

Heat pump; Heating and cooling; Part load performance; Raw water source

Indexed keywords

AIRCONDITIONING SYSTEMS; AMBIENT AIR; BRAZED PLATE HEAT EXCHANGER; CENTRAL CONTROL; COOLING LOAD; COOLING PERFORMANCE; HEAT ENERGY; HEAT PUMPS; HEAT SOURCES; HEATING CAPACITY; HEATING SEASON; PART LOAD; POOR PERFORMANCE; RAW WATER; RAW-WATER SOURCE; SEWAGE WATER; WATER BASED; WATER TREATMENT FACILITIES;

EID: 80053316325     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2011.07.028     Document Type: Article
Times cited : (44)

References (7)
  • 1
    • 71849112569 scopus 로고    scopus 로고
    • Numerical simulation of ground heat and water transfer for groundwater heat pump system based on real-scale experiment
    • Y. Nam, and R. Ooka Numerical simulation of ground heat and water transfer for groundwater heat pump system based on real-scale experiment Energy and Buildings 42 2010 69 75
    • (2010) Energy and Buildings , vol.42 , pp. 69-75
    • Nam, Y.1    Ooka, R.2
  • 2
    • 77949912657 scopus 로고    scopus 로고
    • Development of dual-source hybrid heat pump system using groundwater and air
    • Y. Nam, R. Ooka, and Y. Shiba Development of dual-source hybrid heat pump system using groundwater and air Energy and Buildings 42 2010 909 916
    • (2010) Energy and Buildings , vol.42 , pp. 909-916
    • Nam, Y.1    Ooka, R.2    Shiba, Y.3
  • 3
    • 79551532424 scopus 로고    scopus 로고
    • Year round experimental study on a constant temperature and humidity air-conditioning system driven by ground source heat pump
    • X. Yu, R.Z. Wang, and X.Q. Zhai Year round experimental study on a constant temperature and humidity air-conditioning system driven by ground source heat pump Energy 36 2011 1309 1318
    • (2011) Energy , vol.36 , pp. 1309-1318
    • Yu, X.1    Wang, R.Z.2    Zhai, X.Q.3
  • 4
    • 22544459954 scopus 로고    scopus 로고
    • Underground water-source loop heat-pump air-conditioning system applied in a residential building in Beijing
    • DOI 10.1016/j.apenergy.2004.12.002, PII S0306261904001989
    • C. Chen, F. Sun, L. Feng, and M. Liu Underground water-source heat-pump air-conditioning system applied in a residential building in Beijing Applied Energy 82 2005 331 344 (Pubitemid 41019648)
    • (2005) Applied Energy , vol.82 , Issue.4 , pp. 331-344
    • Chen, C.1    Sun, F.-L.2    Feng, L.3    Liu, M.4
  • 6
    • 0020761388 scopus 로고
    • Using uncertainty analysis in the planning of an experiment
    • R.J. Moffat Using uncertainty analysis in the planning of an experiment Journal of Fluids Engineering 107 1985 173 178
    • (1985) Journal of Fluids Engineering , vol.107 , pp. 173-178
    • Moffat, R.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.