메뉴 건너뛰기




Volumn 11, Issue 9, 2011, Pages 863-869

Biomechanical analysis of a novel posterior construct in a transforaminal lumbar interbody fusion model an in vitro study

Author keywords

Bilateral pedicle screws; Biomechanics; In vitro testing; TLIF; Translaminar facet screws

Indexed keywords

ADULT; AGED; ARTICLE; BIOMECHANICS; BONE SCREW; CADAVER; FEMALE; FRACTURE FIXATION; HUMAN; IN VITRO STUDY; INTERMETHOD COMPARISON; LUMBAR SPINE; LUMBAR SPINE AXIAL ROTATION; LUMBAR SPINE EXTENSION; LUMBAR SPINE FLEXION; LUMBAR SPINE LATERAL BENDING; MALE; MUSCULOSKELETAL SYSTEM PARAMETERS; OUTCOME ASSESSMENT; PEDICLE AND TRANSLAMINAR FACET SCREW CONSTRUCT; PEDICLE SCREW; PRIORITY JOURNAL; PROCESS MODEL; RANGE OF MOTION; SPINAL MOTION SEGMENT STABILITY; SPINE FUSION; SPINE MOBILITY; TRANSFORAMINAL LUMBAR INTERBODY FUSION;

EID: 80053303836     PISSN: 15299430     EISSN: 18781632     Source Type: Journal    
DOI: 10.1016/j.spinee.2011.06.015     Document Type: Article
Times cited : (38)

References (27)
  • 1
    • 33845512540 scopus 로고    scopus 로고
    • Biomechanical comparison of a novel percutaneous transfacet device and a traditional posterior system for single level fusion
    • DOI 10.1097/01.bsd.0000211238.21835.e4, PII 0002472020061200000009
    • A. Mahar, C. Kim, and R. Oka Biomechanical comparison of a novel percutaneous transfacet device and a traditional posterior system for single level fusion J Spinal Disord Tech 19 2006 591 594 (Pubitemid 44912350)
    • (2006) Journal of Spinal Disorders and Techniques , vol.19 , Issue.8 , pp. 591-594
    • Mahar, A.1    Kim, C.2    Oka, R.3    Odell, T.4    Perry, A.5    Mirkovic, S.6    Garfin, S.7
  • 2
    • 0343526849 scopus 로고    scopus 로고
    • Unilateral versus bilateral pedicle screw fixation in lumbar spinal fusion
    • DOI 10.1097/00007632-200007150-00017
    • K.S. Suk, H.M. Lee, N.H. Kim, and J.W. Ha Unilateral versus bilateral pedicle screw fixation in lumbar spinal fusion Spine 25 2000 1843 1847 (Pubitemid 30469664)
    • (2000) Spine , vol.25 , Issue.14 , pp. 1843-1847
    • Suk, K.S.1    Lee, H.M.2    Kim, N.H.3    Ha, J.W.4
  • 3
    • 67349089565 scopus 로고    scopus 로고
    • Transforaminal lumbar interbody fusion using unilateral pedicle screws and a translaminar screw
    • A. Sethi, S. Lee, and R. Vaidya Transforaminal lumbar interbody fusion using unilateral pedicle screws and a translaminar screw Eur Spine J 18 2009 430 434
    • (2009) Eur Spine J , vol.18 , pp. 430-434
    • Sethi, A.1    Lee, S.2    Vaidya, R.3
  • 4
    • 80053305292 scopus 로고    scopus 로고
    • Ipsilateral pedicle screw placement with contralateral percutaneous facet screws: Early results with an alternative in lumbar arthrodesis
    • R.B. Rhiew, S. Manjila, and A.M. Lozen Ipsilateral pedicle screw placement with contralateral percutaneous facet screws: early results with an alternative in lumbar arthrodesis Open Access Surg 2 2009 1 4
    • (2009) Open Access Surg , vol.2 , pp. 1-4
    • Rhiew, R.B.1    Manjila, S.2    Lozen, A.M.3
  • 5
    • 33646559889 scopus 로고    scopus 로고
    • Unilateral pedicle screw instrumentation for minimally invasive transforaminal lumbar interbody fusion
    • W.F. Beringer, and J.P. Mobasser Unilateral pedicle screw instrumentation for minimally invasive transforaminal lumbar interbody fusion Neurosurg Focus 20 2006 E41 E45
    • (2006) Neurosurg Focus , vol.20
    • Beringer, W.F.1    Mobasser, J.P.2
  • 6
    • 33746428750 scopus 로고    scopus 로고
    • Efficacy of translaminar facet screw fixation in circumferential interbody fusions as compared to pedicle screw fixation
    • DOI 10.1097/01.bsd.0000179244.76244.5e, PII 0002472020060400000004
    • N.M. Best, and R.C. Sasso Efficacy of translaminar facet screw fixation in circumferential interbody fusions as compared to pedicle screw fixation J Spinal Disord Tech 19 2006 98 103 (Pubitemid 44284153)
    • (2006) Journal of Spinal Disorders and Techniques , vol.19 , Issue.2 , pp. 98-103
    • Best, N.M.1    Sasso, R.C.2
  • 7
    • 0026101847 scopus 로고
    • Effects of rigidity of an internal fixation device. A comprehensive biomechanical investigation
    • V.K. Goel, T.H. Lim, and J. Gwon Effects of rigidity of an internal fixation device. A comprehensive biomechanical investigation Spine 16 1991 S155 S156
    • (1991) Spine , vol.16
    • Goel, V.K.1    Lim, T.H.2    Gwon, J.3
  • 8
    • 0031811469 scopus 로고    scopus 로고
    • Translaminar screw fixation in the lumbar spine: Technique, indications, results
    • DOI 10.1007/s005860050053
    • D. Grob, and T. Humke Translaminar screw fixation in the lumbar spine: technique, indications, results Eur Spine J 7 1998 178 186 (Pubitemid 28313827)
    • (1998) European Spine Journal , vol.7 , Issue.3 , pp. 178-186
    • Grob, D.1    Humke, T.2
  • 9
    • 0029980342 scopus 로고    scopus 로고
    • Back muscle injury after posterior lumbar spine surgery: A histologic and enzymatic analysis
    • DOI 10.1097/00007632-199604150-00007
    • Y. Kawaguchi, H. Matsui, and H. Tsuji Back muscle injury after posterior lumbar spine surgery: a histologic and enzymatic analysis Spine 21 1996 941 944 (Pubitemid 26127214)
    • (1996) Spine , vol.21 , Issue.8 , pp. 941-944
    • Kawaguchi, Y.1    Matsui, H.2    Tsuji, H.3
  • 10
    • 0026548045 scopus 로고
    • Isolated L4-L5 fusions using the variable screw placement system: Unilateral versus bilateral
    • M.B. Kabins, J.N. Weinstein, and K.F. Spratt Isolated L4-L5 fusions using the variable screw placement system: unilateral versus bilateral J Spinal Disord 5 1992 39 49
    • (1992) J Spinal Disord , vol.5 , pp. 39-49
    • Kabins, M.B.1    Weinstein, J.N.2    Spratt, K.F.3
  • 11
    • 30544452136 scopus 로고    scopus 로고
    • Less invasive posterior fixation method following transforaminal lumbar interbody fusion: A biomechanical analysis
    • DOI 10.1016/j.spinee.2005.08.003, PII S1529943005008314
    • A.V. Slucky, D.S. Brodke, and K.N. Bachus Less invasive posterior fixation method following transforaminal lumbar interbody fusion: a biomechanical analysis Spine J 6 2006 78 85 (Pubitemid 43079179)
    • (2006) Spine Journal , vol.6 , Issue.1 , pp. 78-85
    • Slucky, A.V.1    Brodke, D.S.2    Bachus, K.N.3    Droge, J.A.4    Braun, J.T.5
  • 12
    • 27244442890 scopus 로고    scopus 로고
    • Minimally invasive transforaminal lumbar interbody fusion with ipsilateral pedicle screw and contralateral facet screw fixation
    • J.S. Jang, and S.H. Lee Minimally invasive transforaminal lumbar interbody fusion with ipsilateral pedicle screw and contralateral facet screw fixation J Neurosurg Spine 3 2005 218 223
    • (2005) J Neurosurg Spine , vol.3 , pp. 218-223
    • Jang, J.S.1    Lee, S.H.2
  • 13
    • 4444329571 scopus 로고    scopus 로고
    • Adjacent segment disease after lumbar or lumbosacral fusion: Review of the literature
    • DOI 10.1097/01.brs.0000137069.88904.03
    • P. Park, H.J. Garton, and V.C. Gala Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature Spine 29 2004 1938 1944 (Pubitemid 39181056)
    • (2004) Spine , vol.29 , Issue.17 , pp. 1938-1944
    • Park, P.1    Garton, H.J.2    Gala, V.C.3    Hoff, J.T.4    McGillicuddy, J.E.5
  • 14
    • 0028837713 scopus 로고
    • Postfusion instability at the adjacent segments after rigid pedicle screw fixation for degenerative lumbar spinal disorders
    • Y. Aota, K. Kumano, and S. Hirabayashi Postfusion instability at the adjacent segments after rigid pedicle screw fixation for degenerative lumbar spinal disorders J Spinal Disord 8 1995 464 473
    • (1995) J Spinal Disord , vol.8 , pp. 464-473
    • Aota, Y.1    Kumano, K.2    Hirabayashi, S.3
  • 15
    • 62649169631 scopus 로고    scopus 로고
    • Biomechanical rigidity of an all-polyetheretherketone anterior thoracolumbar spinal reconstruction construct: An in vitro corpectomy model
    • S.M. Moon, A. Ingalhalikar, J.A. Highsmith, and A.R. Vaccaro Biomechanical rigidity of an all-polyetheretherketone anterior thoracolumbar spinal reconstruction construct: an in vitro corpectomy model Spine J 9 2009 330 335
    • (2009) Spine J , vol.9 , pp. 330-335
    • Moon, S.M.1    Ingalhalikar, A.2    Highsmith, J.A.3    Vaccaro, A.R.4
  • 16
    • 78650293755 scopus 로고    scopus 로고
    • A novel crossed rod configuration incorporating translaminar screws for occipitocervical internal fixation: An in vitro biomechanical study
    • G.P. Josue, A.M. Muzumdar, S. Khalil, and A. Ingalhalikar A novel crossed rod configuration incorporating translaminar screws for occipitocervical internal fixation: an in vitro biomechanical study Spine J 11 2011 30 35
    • (2011) Spine J , vol.11 , pp. 30-35
    • Josue, G.P.1    Muzumdar, A.M.2    Khalil, S.3    Ingalhalikar, A.4
  • 18
    • 0031924426 scopus 로고    scopus 로고
    • Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of spinal implants
    • DOI 10.1007/s005860050045
    • H.J. Wilke, K. Wenger, and L. Claes Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants Eur Spine J 7 1998 148 154 (Pubitemid 28223601)
    • (1998) European Spine Journal , vol.7 , Issue.2 , pp. 148-154
    • Wilke, H.-J.1    Wenger, K.2    Claes, L.3
  • 19
    • 0021135620 scopus 로고
    • Stabilization of the lower thoracic and lumbar spine with external skeletal fixation
    • F.P. Magerl Stabilization of the lower thoracic and lumbar spine with external skeletal fixation Clin Orthop Relat Res 189 1984 125 141 (Pubitemid 14024471)
    • (1984) Clinical Orthopaedics and Related Research , vol.189 , pp. 125-141
    • Magerl, F.P.1
  • 20
    • 0033562385 scopus 로고    scopus 로고
    • A follower load increases the load-carrying capacity of the lumbar spine in compression
    • DOI 10.1097/00007632-199905150-00014
    • A.G. Patwardhan, R.M. Havey, and K.P. Meade A follower load increases the load-carrying capacity of the lumbar spine in compression Spine 24 1999 1003 1009 (Pubitemid 29222622)
    • (1999) Spine , vol.24 , Issue.10 , pp. 1003-1009
    • Patwardhan, A.G.1    Havey, R.M.2    Meade, K.P.3    Lee, B.4    Dunlap, B.5
  • 22
    • 0031573532 scopus 로고    scopus 로고
    • Degenerative lumbar spondylolisthesis with spinal stenosis: A prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation
    • DOI 10.1097/00007632-199712150-00003
    • J.S. Fischgrund, M. Mackay, and H.N. Herkowitz 1997 Volvo Award winner in clinical studies. Degenerative lumbar spondylolisthesis with spinal stenosis: a prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation Spine 22 1997 2807 2812 (Pubitemid 28070625)
    • (1997) Spine , vol.22 , Issue.24 , pp. 2807-2812
    • Fischgrund, J.S.1    Mackay, M.2    Herkowitz, H.N.3    Brower, R.4    Montgomery, D.M.5    Kurz, L.T.6
  • 23
    • 33645054088 scopus 로고    scopus 로고
    • Biomechanical comparison of posterior lumbar interbody fusion and transforaminal lumbar interbody fusion performed at 1 and 2 levels
    • C.P. Ames, F.L. Acosta Jr., and J. Chi Biomechanical comparison of posterior lumbar interbody fusion and transforaminal lumbar interbody fusion performed at 1 and 2 levels Spine 30 2005 E562 E566
    • (2005) Spine , vol.30
    • Ames, C.P.1    Acosta, Jr.F.L.2    Chi, J.3
  • 24
    • 15244362216 scopus 로고    scopus 로고
    • Analysis of operative complications in a series of 471 anterior lumbar interbody fusion procedures
    • DOI 10.1097/01.brs.0000155423.18218.75
    • R.C. Sasso, N.M. Best, and P.V. Mummaneni Analysis of operative complications in a series of 471 anterior lumbar interbody fusion procedures Spine 30 2005 670 674 (Pubitemid 40388651)
    • (2005) Spine , vol.30 , Issue.6 , pp. 670-674
    • Sasso, R.C.1    Best, N.M.2    Mummaneni, P.V.3    Reilly, T.M.4    Hussain, S.M.5
  • 25
    • 34748883759 scopus 로고    scopus 로고
    • A comparison of long-term outcomes of translaminar facet screw fixation and pedicle screw fixation: A prospective study
    • DOI 10.3171/SPI-07/09/287
    • J. Tuli, S. Tuli, M.E. Eichler, and E.J. Woodard A comparison of long-term outcomes of translaminar facet screw fixation and pedicle screw fixation: a prospective study J Neurosurg Spine 7 2007 287 292 (Pubitemid 47480453)
    • (2007) Journal of Neurosurgery: Spine , vol.7 , Issue.3 , pp. 287-292
    • Tuli, J.1    Tuli, S.2    Eichler, M.E.3    Woodard, E.J.4
  • 26
    • 3042698903 scopus 로고    scopus 로고
    • Transforaminal lumbar interbody fusion: The effect of various instrumentation techniques on the flexibility of the lumbar spine
    • B.M. Harris, A.S. Hilibrand, and P.E. Savas Transforaminal lumbar interbody fusion: the effect of various instrumentation techniques on the flexibility of the lumbar spine Spine 29 2004 E65 E70
    • (2004) Spine , vol.29
    • Harris, B.M.1    Hilibrand, A.S.2    Savas, P.E.3
  • 27
    • 85047683251 scopus 로고    scopus 로고
    • Biomechanical evaluation of different asymmetrical posterior stabilization methods for minimally invasive transforaminal lumbar interbody fusion laboratory investigation
    • P. Schleicher, P. Beth, and A. Ottenbacher Biomechanical evaluation of different asymmetrical posterior stabilization methods for minimally invasive transforaminal lumbar interbody fusion laboratory investigation J Neurosurg Spine 9 2008 363 371
    • (2008) J Neurosurg Spine , vol.9 , pp. 363-371
    • Schleicher, P.1    Beth, P.2    Ottenbacher, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.