메뉴 건너뛰기




Volumn 95, Issue 10, 2011, Pages 1410-1414

Single versus sequential testing with scanning peripheral anterior chamber depth analyser, IOLMaster and anterior segment optical coherence tomography for the detection of narrow angles

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANTERIOR EYE CHAMBER ANGLE; ANTERIOR EYE CHAMBER DEPTH; ANTERIOR EYE SEGMENT; ARTICLE; CLINICAL ASSESSMENT; CLOSED ANGLE GLAUCOMA; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; GONIOSCOPY; HUMAN; INTERMETHOD COMPARISON; INTERNAL VALIDITY; IOLMASTER; MALE; OPTICAL COHERENCE TOMOGRAPHY; OPTICAL INSTRUMENTATION; PRIORITY JOURNAL; PROSPECTIVE STUDY; SCANNING PERIPHERAL ANTERIOR CHAMBER DEPTH ANALYSER; SENSITIVITY AND SPECIFICITY; SEQUENTIAL ANALYSIS;

EID: 80053263994     PISSN: 00071161     EISSN: 14682079     Source Type: Journal    
DOI: 10.1136/bjo.2009.175869     Document Type: Article
Times cited : (12)

References (21)
  • 1
    • 33645287990 scopus 로고    scopus 로고
    • The epidemiology of age related eye diseases in Asia
    • Wong TY, Loon SC, Saw SM. The epidemiology of age related eye diseases in Asia. Br J Ophthalmol 2006;90:506-11.
    • (2006) Br J Ophthalmol , vol.90 , pp. 506-511
    • Wong, T.Y.1    Loon, S.C.2    Saw, S.M.3
  • 2
    • 0033764724 scopus 로고    scopus 로고
    • YAG laser iridotomy treatment for primary angle closure in east Asian eyes
    • Nolan WP, Foster PJ, Devereux JG, et al. YAG laser iridotomy treatment for primary angle closure in east Asian eyes. Br J Ophthalmol 2000;84:1255-9.
    • (2000) Br J Ophthalmol , vol.84 , pp. 1255-1259
    • Nolan, W.P.1    Foster, P.J.2    Devereux, J.G.3
  • 3
    • 0037341814 scopus 로고    scopus 로고
    • Screening for primary angle closure in Mongolia: A randomised controlled trial to determine whether screening and prophylactic treatment will reduce the incidence of primary angle closure glaucoma in an east Asian population
    • DOI 10.1136/bjo.87.3.271
    • Nolan WP, Baasanhu J, Undraa A, et al. Screening for primary angle closure in Mongolia: a randomised controlled trial to determine whether screening and prophylactic treatment will reduce the incidence of primary angle closure glaucoma in an east Asian population. Br J Ophthalmol 2003;87:271-4. (Pubitemid 36307896)
    • (2003) British Journal of Ophthalmology , vol.87 , Issue.3 , pp. 271-274
    • Nolan, W.P.1    Baasanhu, J.2    Undraa, A.3    Uranchimeg, D.4    Ganzorig, S.5    Johnson, G.J.6
  • 5
    • 52949152877 scopus 로고    scopus 로고
    • Screening for narrow angles in the Singapore population: Evaluation of new noncontact screening methods
    • Lavanya R, Foster PJ, Sakata LM, et al. Screening for narrow angles in the Singapore population: evaluation of new noncontact screening methods. Ophthalmology 2008;115:1720-7, 1727.e1-2.
    • (2008) Ophthalmology , vol.115
    • Lavanya, R.1    Foster, P.J.2    Sakata, L.M.3
  • 7
    • 33748931156 scopus 로고    scopus 로고
    • Development of a fully automated peripheral anterior chamber depth analyzer and evaluation of its accuracy
    • DOI 10.1097/01.ijg.0000212256.25573.44, PII 0006119820061000000007
    • Kashiwagi K, Shinbayashi E, Tsukahara S. Development of a fully automated peripheral anterior chamber depth analyzer and evaluation of its accuracy. J Glaucoma 2006;15:388-93. (Pubitemid 44434991)
    • (2006) Journal of Glaucoma , vol.15 , Issue.5 , pp. 388-393
    • Kashiwagi, K.1    Shinbayashi, E.2    Tsukahara, S.3
  • 8
    • 33646268792 scopus 로고    scopus 로고
    • Finding cases of angle-closure glaucoma in clinic setting using a newly developed instrument
    • Kashiwagi K, Kashiwagi F, Hiejima Y, et al. Finding cases of angle-closure glaucoma in clinic setting using a newly developed instrument. Eye (Lond) 2006;20:319-24.
    • (2006) Eye (Lond) , vol.20 , pp. 319-324
    • Kashiwagi, K.1    Kashiwagi, F.2    Hiejima, Y.3
  • 9
    • 33748945549 scopus 로고    scopus 로고
    • Comparison between newly developed scanning peripheral anterior chamber depth analyzer and conventional methods of evaluating anterior chamber configuration
    • DOI 10.1097/01.ijg.0000212254.17950.0b, PII 0006119820061000000006
    • Kashiwagi K, Tsumura T, Tsukahara S. Comparison between newly developed scanning peripheral anterior chamber depth analyzer and conventional methods of evaluating anterior chamber configuration. J Glaucoma 2006;15:380-7. (Pubitemid 44434990)
    • (2006) Journal of Glaucoma , vol.15 , Issue.5 , pp. 380-387
    • Kashiwagi, K.1    Tsumura, T.2    Tsukahara, S.3
  • 10
    • 43649088112 scopus 로고    scopus 로고
    • Anterior Chamber Angle Assessment Techniques
    • DOI 10.1016/j.survophthal.2007.10.012, PII S0039625707002597
    • Friedman DS, He M. Anterior chamber angle assessment techniques. Surv Ophthalmol 2008;53:250-73. (Pubitemid 351685721)
    • (2008) Survey of Ophthalmology , vol.53 , Issue.3 , pp. 250-273
    • Friedman, D.S.1    He, M.2
  • 11
    • 27144445263 scopus 로고    scopus 로고
    • Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer
    • DOI 10.1016/j.jcrs.2005.02.030, PII S0886335005001720
    • Baikoff G, JitsuoJodai H, Bourgeon G. Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer. J Cataract Refract Surg 2005;31:1722-8. (Pubitemid 41503428)
    • (2005) Journal of Cataract and Refractive Surgery , vol.31 , Issue.9 , pp. 1722-1728
    • Baikoff, G.1    Jodai, H.J.2    Bourgeon, G.3
  • 12
    • 34247239221 scopus 로고    scopus 로고
    • Recent advances in ophthalmic anterior segment imaging: A new era for ophthalmic diagnosis?
    • DOI 10.1136/bjo.2006.103408
    • Konstantopoulos A, Hossain P, Anderson DF. Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis? Br J Ophthalmol 2007;91:551-7. (Pubitemid 46623694)
    • (2007) British Journal of Ophthalmology , vol.91 , Issue.4 , pp. 551-557
    • Konstantopoulos, A.1    Hossain, P.2    Anderson, D.F.3
  • 13
    • 57149085122 scopus 로고    scopus 로고
    • Quantitative analysis of anterior segment optical coherence tomography images: The Zhongshan Angle Assessment Program
    • Console JW, Sakata LM, Aung T, et al. Quantitative analysis of anterior segment optical coherence tomography images: the Zhongshan Angle Assessment Program. Br J Ophthalmol 2008;92:1612-16.
    • (2008) Br J Ophthalmol , vol.92 , pp. 1612-1616
    • Console, J.W.1    Sakata, L.M.2    Aung, T.3
  • 14
    • 0026552857 scopus 로고
    • Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes
    • Pavlin CJ, Harasiewicz K, Foster FS. Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes. Am J Ophthalmol 1992;113:381-9.
    • (1992) Am J Ophthalmol , vol.113 , pp. 381-389
    • Pavlin, C.J.1    Harasiewicz, K.2    Foster, F.S.3
  • 15
    • 0032738125 scopus 로고    scopus 로고
    • Ultrasound biomicroscopy dark room provocative testing: A quantitative method for estimating anterior chamber angle width
    • Ishikawa H, Esaki K, Liebmann JM, et al. Ultrasound biomicroscopy dark room provocative testing: a quantitative method for estimating anterior chamber angle width. Jpn J Ophthalmol 1999;43:526-34.
    • (1999) Jpn J Ophthalmol , vol.43 , pp. 526-534
    • Ishikawa, H.1    Esaki, K.2    Liebmann, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.