메뉴 건너뛰기




Volumn 115, Issue 2, 2011, Pages 157-160

Factors contributing to failure of vacuum delivery and associated maternal/neonatal morbidity

Author keywords

Failed vacuum delivery; Maternal; Morbidity; Neonatal

Indexed keywords

ADULT; APGAR SCORE; CASE CONTROL STUDY; CONTROLLED STUDY; DISEASE ASSOCIATION; FEMALE; FETUS MALFORMATION; HUMAN; MAJOR CLINICAL STUDY; MATERNAL MORBIDITY; MEDICAL RECORD REVIEW; MULTIVARIATE LOGISTIC REGRESSION ANALYSIS; NEWBORN MORBIDITY; PREGNANCY OUTCOME; PRIORITY JOURNAL; RETROSPECTIVE STUDY; REVIEW; VACUUM EXTRACTION;

EID: 80053224891     PISSN: 00207292     EISSN: 18793479     Source Type: Journal    
DOI: 10.1016/j.ijgo.2011.06.016     Document Type: Article
Times cited : (18)

References (22)
  • 2
    • 78650797857 scopus 로고    scopus 로고
    • Indications and maternofetal outcome of instrumental deliveries at the University Teaching Hospital of Yaounde, Cameroon
    • E. Nkwabong, P.N. Nana, R. Mbu, W. Takang, M.R. Ekono, and L. Kouam Indications and maternofetal outcome of instrumental deliveries at the University Teaching Hospital of Yaounde, Cameroon Trop Doct 41 1 2011 5 7
    • (2011) Trop Doct , vol.41 , Issue.1 , pp. 5-7
    • Nkwabong, E.1    Nana, P.N.2    Mbu, R.3    Takang, W.4    Ekono, M.R.5    Kouam, L.6
  • 3
    • 2042503040 scopus 로고    scopus 로고
    • Vacuum extraction: Is there any need to improve the current training in the UK?
    • DOI 10.1111/j.0001-6349.2004.0399.x
    • A. Sau, M. Sau, H. Ahmed, and R. Brown Vacuum extraction: is there any need to improve the current training in the UK? Acta Obstet Gynecol Scand 83 5 2004 466 470 (Pubitemid 38534766)
    • (2004) Acta Obstetricia et Gynecologica Scandinavica , vol.83 , Issue.5 , pp. 466-470
    • Sau, A.1    Sau, M.2    Ahmed, H.3    Brown, R.4
  • 6
    • 0028097249 scopus 로고
    • The role of vacuum extraction in modern obstetrics
    • M.J. Lucas The role of vacuum extraction in modern obstetrics Clin Obstet Gynecol 37 4 1994 794 805 (Pubitemid 24354380)
    • (1994) Clinical Obstetrics and Gynecology , vol.37 , Issue.4 , pp. 794-805
    • Lucas, M.J.1
  • 8
    • 84921431368 scopus 로고    scopus 로고
    • Soft versus rigid vacuum extractor cups for assisted vaginal delivery
    • R. Johanson, and V. Menon Soft versus rigid vacuum extractor cups for assisted vaginal delivery Cochrane Database Syst Rev 2 2000 CD000446
    • (2000) Cochrane Database Syst Rev , Issue.2 , pp. 000446
    • Johanson, R.1    Menon, V.2
  • 9
    • 33646512448 scopus 로고    scopus 로고
    • Head injuries after instrumental vaginal deliveries
    • S.K. Doumouchtsis, and S. Arulkumaran Head injuries after instrumental vaginal deliveries Curr Opin Obstet Gynecol 18 2 2006 129 134
    • (2006) Curr Opin Obstet Gynecol , vol.18 , Issue.2 , pp. 129-134
    • Doumouchtsis, S.K.1    Arulkumaran, S.2
  • 10
    • 0033518193 scopus 로고    scopus 로고
    • Effect of mode of delivery in nulliparous women on neonatal intracranial injury
    • D. Towner, M.A. Castro, E. Eby-Wilkens, and W.M. Gilbert Effect of mode of delivery in nulliparous women on neonatal intracranial injury N Engl J Med 341 23 1999 1709 1714
    • (1999) N Engl J Med , vol.341 , Issue.23 , pp. 1709-1714
    • Towner, D.1    Castro, M.A.2    Eby-Wilkens, E.3    Gilbert, W.M.4
  • 11
    • 34548495857 scopus 로고    scopus 로고
    • Predictors of failed operative vaginal delivery: A single-center experience
    • A. Ben-Haroush, N. Melamed, B. Kaplan, and Y. Yogev Predictors of failed operative vaginal delivery: a single-center experience Am J Obstet Gynecol 197 3 2007 308.e1 308.e5
    • (2007) Am J Obstet Gynecol , vol.197 , Issue.3
    • Ben-Haroush, A.1    Melamed, N.2    Kaplan, B.3    Yogev, Y.4
  • 13
    • 33645008398 scopus 로고    scopus 로고
    • Royal College of Obstetricians and Gynaecologists http://www.rcog.org.uk/ files/rcog-corp/GTG26.pdf Published 2011
    • Royal College of Obstetricians and Gynaecologists Operative Vaginal Delivery (Green-top 26) www.rcog.org http://www.rcog.org.uk/files/rcog-corp/ GTG26.pdf Published 2011
    • Operative Vaginal Delivery (Green-top 26)
  • 16
    • 0038687120 scopus 로고    scopus 로고
    • Failed individual and sequential instrumental vaginal delivery: Contributing risk factors and maternal-neonatal complications
    • DOI 10.1034/j.1600-0412.2003.00162.x
    • H. Al-Kadri, Y. Sabr, S. Al-Saif, B. Abulaimoun, H. Ba'Aqeel, and A. Saleh Failed individual and sequential instrumental vaginal delivery: contributing risk factors and maternal-neonatal complications Acta Obstet Gynecol Scand 82 7 2003 642 648 (Pubitemid 36735139)
    • (2003) Acta Obstetricia et Gynecologica Scandinavica , vol.82 , Issue.7 , pp. 642-648
    • Al-Kadri, H.1    Sabr, Y.2    Al-Saif, S.3    Abulaimoun, B.4    Ba'Aqeel, H.5    Saleh, A.6
  • 17
    • 0034435942 scopus 로고    scopus 로고
    • Vacuum extraction in modern obstetric practice: A review and critique
    • DOI 10.1097/00001703-200012000-00003
    • J.P. O'Grady, C.S. Pope, and S.S. Patel Vacuum extraction in modern obstetric practice: a review and critique Curr Opin Obstet Gynecol 12 6 2000 475 480 (Pubitemid 32673556)
    • (2000) Current Opinion in Obstetrics and Gynecology , vol.12 , Issue.6 , pp. 475-480
    • O'Grady, J.P.1    Pope, C.S.2    Patel, S.S.3
  • 18
    • 0026756748 scopus 로고
    • Effect of angular traction on the performance of modern vacuum extractors
    • K.L. Muise, M.A. Duchon, and R.H. Brown Effect of angular traction on the performance of modern vacuum extractors Am J Obstet Gynecol 167 4 Pt 1 1992 1125 1129
    • (1992) Am J Obstet Gynecol , vol.167 , Issue.4 PART 1 , pp. 1125-1129
    • Muise, K.L.1    Duchon, M.A.2    Brown, R.H.3
  • 20
    • 0036898793 scopus 로고    scopus 로고
    • Clinical evaluation of a "Hand Pump" vacuum delivery device
    • DOI 10.1016/S0029-7844(02)02384-0, PII S0029784402023840
    • R. Hayman, J. Gilby, and S. Arulkumaran Clinical evaluation of a "hand pump" vacuum delivery device Obstet Gynecol 100 6 2002 1190 1195 (Pubitemid 35449184)
    • (2002) Obstetrics and Gynecology , vol.100 , Issue.6 , pp. 1190-1195
    • Hayman, R.1    Gilby, J.2    Arulkumaran, S.3
  • 21
    • 34547673138 scopus 로고    scopus 로고
    • Maternal and neonatal outcome after failed ventouse delivery: Comparison of forceps versus cesarean section
    • DOI 10.1080/14767050701412297, PII 779968902
    • A. Bhide, M. Guven, F. Prefumo, P. Vankalayapati, and B. Thilaganathan Maternal and neonatal outcome after failed ventouse delivery: comparison of forceps versus cesarean section J Matern Fetal Neonatal Med 20 7 2007 541 545 (Pubitemid 47221566)
    • (2007) Journal of Maternal-Fetal and Neonatal Medicine , vol.20 , Issue.7 , pp. 541-545
    • Bhide, A.1    Guven, M.2    Prefumo, F.3    Vankalayapati, P.4    Thilaganathan, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.