메뉴 건너뛰기




Volumn 11, Issue 9, 2011, Pages 8323-8338

A biosensor for urea from succinimide-modified acrylic microspheres based on reflectance transduction

Author keywords

Acrylic microspheres; Optical biosensor; Photopolymerisation; Reflectance; Succinimide; Urea

Indexed keywords

IMMOBILIZED ENZYME; MICROSPHERE; SUCCINIMIDE; SUCCINIMIDE DERIVATIVE; UREA; UREASE;

EID: 80053204432     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s110908323     Document Type: Article
Times cited : (41)

References (35)
  • 1
    • 0030964378 scopus 로고    scopus 로고
    • Studies on a potentiometric urea biosensor based on an ammonia electrode and urease, immobilized on a γ-aluminium oxide matrix
    • Liu, B.; Hu, R.; Deng, J. Studies on a potentiometric urea biosensor based on an ammonia electrode and urease, immobilized on a γ-aluminium oxide matrix. Anal. Chim. Acta 1997, 341, 161-169.
    • (1997) Anal. Chim. Acta , vol.341 , pp. 161-169
    • Liu, B.1    Hu, R.2    Deng, J.3
  • 3
    • 0033991965 scopus 로고    scopus 로고
    • Sol-gel-derived thick-film conductometric biosensor for urea determination in serum
    • Lee, W.Y.; Kim, S.R.; Kim, T.H.; Lee, K.S.; Shin, M.C.; Park, J.K. Sol-gel-derived thick-film conductometric biosensor for urea determination in serum. Anal. Chim. Acta 2000, 404, 195-203.
    • (2000) Anal. Chim. Acta , vol.404 , pp. 195-203
    • Lee, W.Y.1    Kim, S.R.2    Kim, T.H.3    Lee, K.S.4    Shin, M.C.5    Park, J.K.6
  • 4
    • 2342496713 scopus 로고    scopus 로고
    • Urea biosensor based on PANi (urease)®/Au composite electrode
    • Luo, Y.C.; Do, J.S. Urea biosensor based on PANi (urease)®/Au composite electrode. Biosens. Bioelectron. 2004, 20, 15-23.
    • (2004) Biosens. Bioelectron , vol.20 , pp. 15-23
    • Luo, Y.C.1    Do, J.S.2
  • 5
    • 0036016414 scopus 로고    scopus 로고
    • Immobilization of urease on poly(N-vinyl carbazole)/stearic acid Langmuir-Blodgett films for application to urea biosensor
    • Singhal, R.; Gambhir, A.; Pandey, M.K.; Annapoorni, S.; Malhotra, B.D. Immobilization of urease on poly(N-vinyl carbazole)/stearic acid Langmuir-Blodgett films for application to urea biosensor. Biosens. Bioelectron. 2002, 17, 697-703.
    • (2002) Biosens. Bioelectron , vol.17 , pp. 697-703
    • Singhal, R.1    Gambhir, A.2    Pandey, M.K.3    Annapoorni, S.4    Malhotra, B.D.5
  • 6
    • 36049047301 scopus 로고    scopus 로고
    • A urea biosensor from stacked sol-gel films with immobilized Nile blue chromoionophore and urease enzyme
    • Muawia, S.A.; Lee, Y.H.; Musa, A. A urea biosensor from stacked sol-gel films with immobilized Nile blue chromoionophore and urease enzyme. Sensor 2007, 7, 2251-2262.
    • (2007) Sensor , vol.7 , pp. 2251-2262
    • Muawia, S.A.1    Lee, Y.H.2    Musa, A.3
  • 7
    • 0033598186 scopus 로고    scopus 로고
    • A miniaturized urea sensor based on the integration of both ammonium based urease enzyme field effect transistor and a reference field effect transistor for in a single chip
    • Senillou, A.; Renault, N.J.; Martelet, C.; Consnier, S. A miniaturized urea sensor based on the integration of both ammonium based urease enzyme field effect transistor and a reference field effect transistor for in a single chip. Talanta 1999, 50, 219-226.
    • (1999) Talanta , vol.50 , pp. 219-226
    • Senillou, A.1    Renault, N.J.2    Martelet, C.3    Consnier, S.4
  • 8
    • 0021297386 scopus 로고
    • Determination of urea in whole blood using a urea electrode with immobilized urease membrane
    • Yashuda, K.; Miyagi, H.; Hamada, Y.; Takata, Y. Determination of urea in whole blood using a urea electrode with immobilized urease membrane. Analyst 1984, 109, 61-64.
    • (1984) Analyst , vol.109 , pp. 61-64
    • Yashuda, K.1    Miyagi, H.2    Hamada, Y.3    Takata, Y.4
  • 9
    • 0015425913 scopus 로고
    • Enzyme electrode based on the use of carbon dioxide sensor
    • Guilbault, G.G.; Shu, F.R. Enzyme electrode based on the use of carbon dioxide sensor. Anal. Chem. 1972, 44, 2161-2165.
    • (1972) Anal. Chem , vol.44 , pp. 2161-2165
    • Guilbault, G.G.1    Shu, F.R.2
  • 10
    • 0018434019 scopus 로고
    • Enzymatic determination of urea in serum based on pH measurement with flow injection method
    • Ruzicka, J.; Hansen, E.H.; Ghose, K. Enzymatic determination of urea in serum based on pH measurement with flow injection method. Anal. Chem. 1979, 51, 199-206.
    • (1979) Anal. Chem , vol.51 , pp. 199-206
    • Ruzicka, J.1    Hansen, E.H.2    Ghose, K.3
  • 11
    • 0016371052 scopus 로고
    • Specific enzyme electrode for urea
    • Guilbault, G.G.; Trap, M.A. Specific enzyme electrode for urea. Anal. Chim. Acta 1974, 73, 355-365.
    • (1974) Anal. Chim. Acta , vol.73 , pp. 355-365
    • Guilbault, G.G.1    Trap, M.A.2
  • 12
    • 0032170809 scopus 로고    scopus 로고
    • Urea potentiometric biosensor based on urease immobilized on chitosan membranes
    • Magalhães, J.M.; Machado, A.A. Urea potentiometric biosensor based on urease immobilized on chitosan membranes. Talanta 1998, 47, 183-191.
    • (1998) Talanta , vol.47 , pp. 183-191
    • Magalhães, J.M.1    McHado, A.A.2
  • 13
    • 0037178188 scopus 로고    scopus 로고
    • Enhancement of operational stability of an enzyme biosensor for glucose and sucrose using protein based stabilizing agents
    • Gouda, M.D.; Kumar, M.A.; Thakur, M.S.; Karanth, N.G. Enhancement of operational stability of an enzyme biosensor for glucose and sucrose using protein based stabilizing agents. Biosens. Bioelectron. 2002, 17, 503-507.
    • (2002) Biosens. Bioelectron , vol.17 , pp. 503-507
    • Gouda, M.D.1    Kumar, M.A.2    Thakur, M.S.3    Karanth, N.G.4
  • 14
    • 2442453337 scopus 로고    scopus 로고
    • Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films
    • Lakard, B.; Herlem, G.; Lakard, S.; Antoniou, A.; Fahys, B. Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films. Biosens. Bioelectron. 2004, 19, 1641-1647.
    • (2004) Biosens. Bioelectron , vol.19 , pp. 1641-1647
    • Lakard, B.1    Herlem, G.2    Lakard, S.3    Antoniou, A.4    Fahys, B.5
  • 16
    • 1342306779 scopus 로고    scopus 로고
    • A novel method to construct a third-generation biosensor: Self-assembling gold nanoparticles on thiol-functionlized poly(styrene-co-acrylic acid) nanospheres
    • Xu, S.; Han, X. A novel method to construct a third-generation biosensor: Self-assembling gold nanoparticles on thiol-functionlized poly(styrene-co-acrylic acid) nanospheres. Biosens. Bioelectron. 2004, 19, 1117-1120.
    • (2004) Biosens. Bioelectron , vol.19 , pp. 1117-1120
    • Xu, S.1    Han, X.2
  • 17
    • 33744994339 scopus 로고    scopus 로고
    • Self-assembling gold nanoparticles on thiol-functionalized poly(styrene-co-acrylic acid) nanospheres for fabrication of a mediatorless biosensor
    • Xu, S.; Tu, G.; Peng, B.; Han, X. Self-assembling gold nanoparticles on thiol-functionalized poly(styrene-co-acrylic acid) nanospheres for fabrication of a mediatorless biosensor. Anal. Chim. Acta 2006, 570, 151-157.
    • (2006) Anal. Chim. Acta , vol.570 , pp. 151-157
    • Xu, S.1    Tu, G.2    Peng, B.3    Han, X.4
  • 18
    • 33846587198 scopus 로고    scopus 로고
    • A third-generation H2O2 biosensor based on horseradish peroxidase-labeled Au nanoparticles self-assembled to hollow porous polymeric nanopheres
    • Xu, S.; Peng, B.; Han, X. A third-generation H2O2 biosensor based on horseradish peroxidase-labeled Au nanoparticles self-assembled to hollow porous polymeric nanopheres. Biosens. Bioelectron. 2007, 22, 1807-1810.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 1807-1810
    • Xu, S.1    Peng, B.2    Han, X.3
  • 19
    • 33646564967 scopus 로고    scopus 로고
    • An optical biosensor for dichlovos using stacked sol-gel containing acetylcholinesterase and a lipophilic chromoionophore
    • Wong, F.C.M.; Ahmad, M.; Heng, L.Y.; Peng, L.B. An optical biosensor for dichlovos using stacked sol-gel containing acetylcholinesterase and a lipophilic chromoionophore. Talanta 2006, 69, 888-893.
    • (2006) Talanta , vol.69 , pp. 888-893
    • Wong, F.C.M.1    Ahmad, M.2    Heng, L.Y.3    Peng, L.B.4
  • 20
    • 1842868513 scopus 로고    scopus 로고
    • Optical biosensor for urea with improve response time
    • Kovács, B.; Nagy, G.R.; Dombi, R.; Tóth, K. Optical biosensor for urea with improve response time. Biosens. Bioelectron. 2003, 18, 111-118.
    • (2003) Biosens. Bioelectron , vol.18 , pp. 111-118
    • Kovács, B.1    Nagy, G.R.2    Dombi, R.3    Tóth, K.4
  • 21
    • 0027218103 scopus 로고
    • Fluorescence optical urea biosensor with an ammonium optrode as transducer
    • Wofbies, O.S.; Li, H. Fluorescence optical urea biosensor with an ammonium optrode as transducer. Biosens. Bioelectron. 1993, 8, 161-166.
    • (1993) Biosens. Bioelectron , vol.8 , pp. 161-166
    • Wofbies, O.S.1    Li, H.2
  • 22
    • 0034005332 scopus 로고    scopus 로고
    • A poly(N-isopropylacrylamide-co-N-acryloxysuccinimede-co-2-hydroxyethyl methacrylate) composite hydrogel membrane for urease immobilization to enhance urea hydrolysis rate by temperature swing
    • Chen, J.P.; Chiu, S.H. A poly(N-isopropylacrylamide-co-N-acryloxysuccinimede-co-2-hydroxyethyl methacrylate) composite hydrogel membrane for urease immobilization to enhance urea hydrolysis rate by temperature swing. Enzym. Micro. Technol. 2000, 26, 359-367.
    • (2000) Enzym. Micro. Technol , vol.26 , pp. 359-367
    • Chen, J.P.1    Chiu, S.H.2
  • 23
    • 0037447792 scopus 로고    scopus 로고
    • Surface functionalization of oil-in-water nanoemulsion with a reactive copolymer: Colloidal characterization and peptide immobilization
    • Chaix, C.; Pacard, E.; Elaissari, A.; Hilaire, J.F.; Picot, C. Surface functionalization of oil-in-water nanoemulsion with a reactive copolymer: Colloidal characterization and peptide immobilization. Colloids Surf. B 2002, 29, 39-52.
    • (2002) Colloids Surf. B , vol.29 , pp. 39-52
    • Chaix, C.1    Pacard, E.2    Elaissari, A.3    Hilaire, J.F.4    Picot, C.5
  • 24
    • 0029917011 scopus 로고    scopus 로고
    • Linearization of the bradford protein assay increases its sensitivity: Theoretical and experimental studies
    • Zor, T.; Selinger, Z. Linearization of the bradford protein assay increases its sensitivity: Theoretical and experimental studies. Anal. Biochem. 1996, 36, 302-308.
    • (1996) Anal. Biochem , vol.36 , pp. 302-308
    • Zor, T.1    Selinger, Z.2
  • 26
    • 0002849122 scopus 로고    scopus 로고
    • Methacrylic-acrylic polymers in ion-selective membranes: Achieving theright polymer recipe
    • Lee, Y.H.; Hall, E.A.H. Methacrylic-acrylic polymers in ion-selective membranes: Achieving theright polymer recipe. Anal. Chim. Acta 2000, 403, 77-89.
    • (2000) Anal. Chim. Acta , vol.403 , pp. 77-89
    • Lee, Y.H.1    Hall, E.A.H.2
  • 27
    • 0345096626 scopus 로고    scopus 로고
    • Particle size distribution in mini-emulsion polymerization
    • Landfester, K.; Schork, F.J.; Kusuma, V.A. Particle size distribution in mini-emulsion polymerization. Compt. Rendus Chim. 2003, 6, 1337-1342.
    • (2003) Compt. Rendus Chim , vol.6 , pp. 1337-1342
    • Landfester, K.1    Schork, F.J.2    Kusuma, V.A.3
  • 28
    • 18144397430 scopus 로고    scopus 로고
    • Preparation and characterization of magnetic polymer nanospheres with high protein binding capacity
    • Liu, X.Q.; Guan, Y.P.; Liu, H.Z.; Ma, Z.Y.; Yang, Y.; Wu, X.B. Preparation and characterization of magnetic polymer nanospheres with high protein binding capacity. J. Magn. Magn. Mater. 2005, 293, 111-118.
    • (2005) J. Magn. Magn. Mater , vol.293 , pp. 111-118
    • Liu, X.Q.1    Guan, Y.P.2    Liu, H.Z.3    Ma, Z.Y.4    Yang, Y.5    Wu, X.B.6
  • 29
    • 80053200798 scopus 로고
    • ACS Symposium Series 556; American Chemical Society: Washington, DC, USA
    • Usmani, A.; Akmal, N. Diagnostic Biosensor Polymer; ACS Symposium Series 556; American Chemical Society: Washington, DC, USA, 1994.
    • (1994) Diagnostic Biosensor Polymer
    • Usmani, A.1    Akmal, N.2
  • 30
    • 0033521508 scopus 로고    scopus 로고
    • The effect of phosphate buffer in the range of pH 5.80-8.07 on jack bean urease activity
    • Krajewska, B.; Zaborska, W. The effect of phosphate buffer in the range of pH 5.80-8.07 on jack bean urease activity. J. Mol. Catal. B: Enzym. 1999, 6, 75-81.
    • (1999) J. Mol. Catal. B: Enzym , vol.6 , pp. 75-81
    • Krajewska, B.1    Zaborska, W.2
  • 31
    • 33646564967 scopus 로고    scopus 로고
    • An optical biosensor for dichlovos using stacked sol-gel films containing acetylcholinesterase and a lipophilic chromoionophore
    • Francis, C.M.W.; Musa, A.; Lee, Y.H.; Lim, B.P. An optical biosensor for dichlovos using stacked sol-gel films containing acetylcholinesterase and a lipophilic chromoionophore. Talanta 2006, 69, 888-893.
    • (2006) Talanta , vol.69 , pp. 888-893
    • Francis, C.M.W.1    Musa, A.2    Lee, Y.H.3    Lim, B.P.4
  • 32
    • 12844287697 scopus 로고    scopus 로고
    • Simultaneous determination of pH, urea, acethylcholine and heavy metals using array-based enzymatic optical biosensor
    • Tsai, H.C.; Dong, R. Simultaneous determination of pH, urea, acethylcholine and heavy metals using array-based enzymatic optical biosensor. Biosens. Bioelectron. 2005, 20, 1796-1804.
    • (2005) Biosens. Bioelectron , vol.20 , pp. 1796-1804
    • Tsai, H.C.1    Dong, R.2
  • 33
    • 77956176992 scopus 로고    scopus 로고
    • Nanoengineered optical urea biosensor for estimating hemodialysis parameters in spent dialysate
    • Swati, M.; Hase, N.K.; Srivastava, R. Nanoengineered optical urea biosensor for estimating hemodialysis parameters in spent dialysate. Anal. Chim. Acta 2010, 676, 68-74.
    • (2010) Anal. Chim. Acta , vol.676 , pp. 68-74
    • Swati, M.1    Hase, N.K.2    Srivastava, R.3
  • 34
    • 0029114847 scopus 로고
    • Enzyme biosensor for urea based on a novel pH bulk optode membrane
    • Koncki, R.; Mohr, G.J.; Wolfe's, O.S. Enzyme biosensor for urea based on a novel pH bulk optode membrane. Biosens. Bioelectron. 1995, 10, 653-659.
    • (1995) Biosens. Bioelectron , vol.10 , pp. 653-659
    • Koncki, R.1    Mohr, G.J.2    Wolfe's, O.S.3
  • 35
    • 80053212503 scopus 로고    scopus 로고
    • Development of an optical urea biosensor using polypyrrole-polyvinyl sulphonate film
    • Kharat, H.J.; Datta, K.; Ghosh, P.; Shirsat, M.S. Development of an optical urea biosensor using polypyrrole-polyvinyl sulphonate film. Sens. Trans. J. 2009, 101, 112-122.
    • (2009) Sens. Trans. J , vol.101 , pp. 112-122
    • Kharat, H.J.1    Datta, K.2    Ghosh, P.3    Shirsat, M.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.