-
1
-
-
0036216170
-
Determination of zinc levels in waters from southeastern Spain by electrothermal atomic absorption spectrometry: relationship with industrial activity
-
Terres-Martos C, Navarro-Alarcon M, Martin-Lagos F, Gimenez-Martinez R, Lopez-Garcia De La Serrena H, Lopez Martinez MC (2002) Determination of zinc levels in waters from southeastern Spain by electrothermal atomic absorption spectrometry: relationship with industrial activity. Water Res 36: 1912-1916.
-
(2002)
Water Res
, vol.36
, pp. 1912-1916
-
-
Terres-Martos, C.1
Navarro-Alarcon, M.2
Martin-Lagos, F.3
Gimenez-Martinez, R.4
de la Lopez-Garcia, S.H.5
Lopez Martinez, M.C.6
-
2
-
-
33746512675
-
Cloud point extraction and spectrofluorimetric determination of aluminium and zinc in foodstuffs and water samples
-
Bavili Tabrizi A (2007) Cloud point extraction and spectrofluorimetric determination of aluminium and zinc in foodstuffs and water samples. Food Chem 100: 1698-1703.
-
(2007)
Food Chem
, vol.100
, pp. 1698-1703
-
-
Bavili Tabrizi, A.1
-
3
-
-
0343826869
-
Determination of zinc, cadmium, cobalt and nickel by flame atomic absorption spectrometry after preconcentration by poly(ethylene terephthalate) fibers grafted with methacrylic acid
-
Bag H, Turker AR, Coskun R, Sacak M, Yigitoglu M (2000) Determination of zinc, cadmium, cobalt and nickel by flame atomic absorption spectrometry after preconcentration by poly(ethylene terephthalate) fibers grafted with methacrylic acid. Spectrochim Acta B 55: 1099-1106.
-
(2000)
Spectrochim Acta B
, vol.55
, pp. 1099-1106
-
-
Bag, H.1
Turker, A.R.2
Coskun, R.3
Sacak, M.4
Yigitoglu, M.5
-
4
-
-
0037417181
-
On-line preconcentration system using a minicolumn of polyurethane foam loaded with Me-BTABr for zinc determination by flame atomic absorption spectrometry
-
Lemos VA, Lopes dos Santos WN, Santos JS, de Carvalho MB (2003) On-line preconcentration system using a minicolumn of polyurethane foam loaded with Me-BTABr for zinc determination by flame atomic absorption spectrometry. Anal Chim Acta 481: 283-290.
-
(2003)
Anal Chim Acta
, vol.481
, pp. 283-290
-
-
Lemos, V.A.1
dos Lopes, S.W.N.2
Santos, J.S.3
de Carvalho, M.B.4
-
5
-
-
7944231927
-
Determination of lead, copper, manganese and zinc in botanic and other biological samples by electrothermal atomic absorption spectrometry using scandium-containing chemical modifiers
-
Acar O (2004) Determination of lead, copper, manganese and zinc in botanic and other biological samples by electrothermal atomic absorption spectrometry using scandium-containing chemical modifiers. Anal Chim Acta 526: 103-109.
-
(2004)
Anal Chim Acta
, vol.526
, pp. 103-109
-
-
Acar, O.1
-
6
-
-
34548853727
-
Flow injection on-line dilution for zinc determination in human saliva with electrothermal atomic absorption spectrometry detection
-
Burguera-Pascu M, Rodriguez-Archilla A, Burguera JL, Burguera M, Rondon C, Carrero P (2007) Flow injection on-line dilution for zinc determination in human saliva with electrothermal atomic absorption spectrometry detection. Anal Chim Acta 600: 214-220.
-
(2007)
Anal Chim Acta
, vol.600
, pp. 214-220
-
-
Burguera-Pascu, M.1
Rodriguez-Archilla, A.2
Burguera, J.L.3
Burguera, M.4
Rondon, C.5
Carrero, P.6
-
7
-
-
79960768452
-
Use of multivariate analysis techniques for the characterization of analytical results for the determination of the mineral composition of kale
-
Fadigas JC, dos Santos AMP, de Jesus RM, Lima DC, Fragoso WD, David JM, Ferreira SLC (2010) Use of multivariate analysis techniques for the characterization of analytical results for the determination of the mineral composition of kale. Microchem J 96: 352-356.
-
(2010)
Microchem J
, vol.96
, pp. 352-356
-
-
Fadigas, J.C.1
dos Santos, A.M.P.2
de Jesus, R.M.3
Lima, D.C.4
Fragoso, W.D.5
David, J.M.6
Ferreira, S.L.C.7
-
8
-
-
77955576900
-
Determination of toxic and other trace elements in calcium-rich materials using cloud point extraction and inductively coupled plasma emission spectrometry
-
Borkowska-Burnecka J, Szymczycha-Madeja A, Zyrnicki W (2010) Determination of toxic and other trace elements in calcium-rich materials using cloud point extraction and inductively coupled plasma emission spectrometry. J Hazard Mater 182: 477-483.
-
(2010)
J Hazard Mater
, vol.182
, pp. 477-483
-
-
Borkowska-Burnecka, J.1
Szymczycha-Madeja, A.2
Zyrnicki, W.3
-
9
-
-
78149283615
-
Determination of trace elements in biological samples treated with formic acid by inductively coupled plasma mass spectrometry using a microconcentric nebulizer
-
Tormen L, Gil RA, Frescura VLA, Martinez LD, Curtius AJ (2010) Determination of trace elements in biological samples treated with formic acid by inductively coupled plasma mass spectrometry using a microconcentric nebulizer. Spectrochim Acta B 65: 959-966.
-
(2010)
Spectrochim Acta B
, vol.65
, pp. 959-966
-
-
Tormen, L.1
Gil, R.A.2
Frescura, V.L.A.3
Martinez, L.D.4
Curtius, A.J.5
-
10
-
-
38149047538
-
An optical sensor for zinc determination based on Zincon as sensing reagent
-
Rastegarzadeh S, Rezaei V (2008) An optical sensor for zinc determination based on Zincon as sensing reagent. Sens Actuator B-Chem 129: 327-331.
-
(2008)
Sens Actuator B-Chem
, vol.129
, pp. 327-331
-
-
Rastegarzadeh, S.1
Rezaei, V.2
-
11
-
-
33847719486
-
Sequential injection spectrophotometric determination of zinc(II) in pharmaceuticals based on zinc(II)-PAN in non-ionic surfactant medium
-
Thanasarakhan W, Liawruangrath S, Wangkarn S, Liawruangrath B (2007) Sequential injection spectrophotometric determination of zinc(II) in pharmaceuticals based on zinc(II)-PAN in non-ionic surfactant medium. Talanta 71: 1849-1855.
-
(2007)
Talanta
, vol.71
, pp. 1849-1855
-
-
Thanasarakhan, W.1
Liawruangrath, S.2
Wangkarn, S.3
Liawruangrath, B.4
-
12
-
-
55149118019
-
Differential pulse stripping voltammetric determination of heavy metals simultaneously using new polymer modified glassy carbon electrodes
-
Manisankar P, Vedhi C, Selvanathan G, Arumugam P (2008) Differential pulse stripping voltammetric determination of heavy metals simultaneously using new polymer modified glassy carbon electrodes. Microchim Acta 163: 289-295.
-
(2008)
Microchim Acta
, vol.163
, pp. 289-295
-
-
Manisankar, P.1
Vedhi, C.2
Selvanathan, G.3
Arumugam, P.4
-
13
-
-
79551570353
-
Simultaneous determination of trace zinc and cadmium by anodic stripping voltammetry using a polymeric film nanoparticle self-assembled electrode
-
Gholivand MB, Azadbakht A, Pashabadi A (2011) Simultaneous determination of trace zinc and cadmium by anodic stripping voltammetry using a polymeric film nanoparticle self-assembled electrode. Electroanal 23: 364-370.
-
(2011)
Electroanal
, vol.23
, pp. 364-370
-
-
Gholivand, M.B.1
Azadbakht, A.2
Pashabadi, A.3
-
14
-
-
33646176823
-
Determination of organic compounds in water using dispersive liquid-liquid microextraction
-
Rezaee M, Assadi Y, Milani Hosseini MR, Aghaee E, Ahmadi F, Berijani S (2006) Determination of organic compounds in water using dispersive liquid-liquid microextraction. J Chromatogr A 1116: 1-9.
-
(2006)
J Chromatogr A
, vol.1116
, pp. 1-9
-
-
Rezaee, M.1
Assadi, Y.2
Milani Hosseini, M.R.3
Aghaee, E.4
Ahmadi, F.5
Berijani, S.6
-
15
-
-
33745712205
-
Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection. Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water
-
Berijani S, Assadi Y, Anbia M, Milani Hosseini MR, Aghaee E (2006) Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection. Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water. J Chromatogr A 1123: 1-9.
-
(2006)
J Chromatogr A
, vol.1123
, pp. 1-9
-
-
Berijani, S.1
Assadi, Y.2
Anbia, M.3
Milani Hosseini, M.R.4
Aghaee, E.5
-
16
-
-
33846581110
-
Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry. Ultra trace determination of cadmium in water samples
-
Jahromi EZ, Bidari A, Assadi Y, Milani Hosseini MR, Jamali MR (2007) Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry. Ultra trace determination of cadmium in water samples. Anal Chim Acta 585: 305-311.
-
(2007)
Anal Chim Acta
, vol.585
, pp. 305-311
-
-
Jahromi, E.Z.1
Bidari, A.2
Assadi, Y.3
Milani Hosseini, M.R.4
Jamali, M.R.5
-
17
-
-
70449530613
-
Speciation of chromium in water samples using dispersive liquid-liquid microextraction and flame atomic absorption spectrometry
-
Hemmatkhah P, Bidari A, Jafarvand S, Milani Hosseini MR, Assadi Y (2009) Speciation of chromium in water samples using dispersive liquid-liquid microextraction and flame atomic absorption spectrometry. Microchim Acta 166: 69-75.
-
(2009)
Microchim Acta
, vol.166
, pp. 69-75
-
-
Hemmatkhah, P.1
Bidari, A.2
Jafarvand, S.3
Milani Hosseini, M.R.4
Assadi, Y.5
-
18
-
-
70449532136
-
Preconcentration and determination of ultra trace amounts of palladium in water samples by dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry
-
Shamsipur M, Ramezani M, Sadeghi M (2009) Preconcentration and determination of ultra trace amounts of palladium in water samples by dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry. Microchim Acta 166: 235-242.
-
(2009)
Microchim Acta
, vol.166
, pp. 235-242
-
-
Shamsipur, M.1
Ramezani, M.2
Sadeghi, M.3
-
19
-
-
55149089898
-
Selenium analysis in water samples by dispersive liquid-liquid microextraction based on piazselenol formation and GC-ECD
-
Bidari A, Hemmatkhah P, Jafarvand S, Milani Hosseini MR, Assadi Y (2008) Selenium analysis in water samples by dispersive liquid-liquid microextraction based on piazselenol formation and GC-ECD. Microchim Acta 163: 243-249.
-
(2008)
Microchim Acta
, vol.163
, pp. 243-249
-
-
Bidari, A.1
Hemmatkhah, P.2
Jafarvand, S.3
Milani Hosseini, M.R.4
Assadi, Y.5
-
20
-
-
29944441835
-
Analytical applications of room-temperature ionic liquids: A review of recent efforts
-
Pandey S (2006) Analytical applications of room-temperature ionic liquids: A review of recent efforts. Anal Chim Acta 556: 38-45.
-
(2006)
Anal Chim Acta
, vol.556
, pp. 38-45
-
-
Pandey, S.1
-
21
-
-
8144227915
-
Use of 1-alkyl-3-methylimidazolium hexafluorophosphate room temperature ionic liquids as chelate extraction solvent with 4,4,4-trifluoro-1-(2-thienyl)-1,3-butanedione
-
Hirayama N, Deguchi M, Kawasumi H, Honjo T (2005) Use of 1-alkyl-3-methylimidazolium hexafluorophosphate room temperature ionic liquids as chelate extraction solvent with 4, 4, 4-trifluoro-1-(2-thienyl)-1, 3-butanedione. Talanta 65: 255-260.
-
(2005)
Talanta
, vol.65
, pp. 255-260
-
-
Hirayama, N.1
Deguchi, M.2
Kawasumi, H.3
Honjo, T.4
-
22
-
-
64049088822
-
Room temperature ionic liquid-based microextraction for vanadium species separation and determination in water samples by electrothermal atomic absorption spectrometry
-
Berton P, Martinis EM, Martinezc LD, Wuilloud RG (2009) Room temperature ionic liquid-based microextraction for vanadium species separation and determination in water samples by electrothermal atomic absorption spectrometry. Anal Chim Acta 640: 40-46.
-
(2009)
Anal Chim Acta
, vol.640
, pp. 40-46
-
-
Berton, P.1
Martinis, E.M.2
Martinezc, L.D.3
Wuilloud, R.G.4
-
23
-
-
64549156479
-
Cold-induced aggregation microextraction based on ionic liquids and fiber optic-linear array detection spectrophotometry of cobalt in water samples
-
Gharehbaghi M, Shemirani F, Farahani MD (2009) Cold-induced aggregation microextraction based on ionic liquids and fiber optic-linear array detection spectrophotometry of cobalt in water samples. J Hazard Mater 165: 1049-1055.
-
(2009)
J Hazard Mater
, vol.165
, pp. 1049-1055
-
-
Gharehbaghi, M.1
Shemirani, F.2
Farahani, M.D.3
-
24
-
-
77049092513
-
Ionic liquid-based single-drop microextraction followed by liquid chromatography-ultraviolet spectrophotometry detection to determine typical UV filters in surface water samples
-
Vidal L, Chisvert A, Canals A, Salvador A (2010) Ionic liquid-based single-drop microextraction followed by liquid chromatography-ultraviolet spectrophotometry detection to determine typical UV filters in surface water samples. Talanta 81: 549-555.
-
(2010)
Talanta
, vol.81
, pp. 549-555
-
-
Vidal, L.1
Chisvert, A.2
Canals, A.3
Salvador, A.4
-
25
-
-
53949099622
-
Determination of trihalomethanes in waters by ionic liquid-based single drop microextraction/gas chromatographic/mass spectrometry
-
Aguilera-Herrador E, Lucena R, Cardenas S, Valcarcel M (2008) Determination of trihalomethanes in waters by ionic liquid-based single drop microextraction/gas chromatographic/mass spectrometry. J Chromatogr A 1209: 76-82.
-
(2008)
J Chromatogr A
, vol.1209
, pp. 76-82
-
-
Aguilera-Herrador, E.1
Lucena, R.2
Cardenas, S.3
Valcarcel, M.4
-
26
-
-
46149106139
-
Ionic liquid for improved single-drop microextraction of aromatic amines in water samples
-
Zhou Q, Ye C (2008) Ionic liquid for improved single-drop microextraction of aromatic amines in water samples. Microchim Acta 162: 153-159.
-
(2008)
Microchim Acta
, vol.162
, pp. 153-159
-
-
Zhou, Q.1
Ye, C.2
-
27
-
-
70350218839
-
Dispersive liquid-liquid microextraction using an in situ metathesis reaction to form an ionic liquid extraction phase for the preconcentration of aromatic compounds from water
-
Yao C, Anderson JL (2009) Dispersive liquid-liquid microextraction using an in situ metathesis reaction to form an ionic liquid extraction phase for the preconcentration of aromatic compounds from water. Anal Bioanal Chem 395: 1491-1502.
-
(2009)
Anal Bioanal Chem
, vol.395
, pp. 1491-1502
-
-
Yao, C.1
Anderson, J.L.2
-
28
-
-
79952107635
-
Selective extraction of emerging contaminants from water samples by dispersive liquid-liquid microextraction using functionalized ionic liquids
-
Yao C, Li T, Twu P, Pitner WR, Anderson JL (2011) Selective extraction of emerging contaminants from water samples by dispersive liquid-liquid microextraction using functionalized ionic liquids. J Chromatogr A 1218: 1556-1566.
-
(2011)
J Chromatogr A
, vol.1218
, pp. 1556-1566
-
-
Yao, C.1
Li, T.2
Twu, P.3
Pitner, W.R.4
Anderson, J.L.5
-
29
-
-
56749178643
-
Dispersive liquid-liquid microextraction based on ionic liquid and spectrophotometric determination of mercury in water samples
-
Gharehbaghi M, Shemirani F, Baghdadi M (2009) Dispersive liquid-liquid microextraction based on ionic liquid and spectrophotometric determination of mercury in water samples. Int J Environ An Ch 89: 21-33.
-
(2009)
Int J Environ aN Ch
, vol.89
, pp. 21-33
-
-
Gharehbaghi, M.1
Shemirani, F.2
Baghdadi, M.3
-
30
-
-
77949283095
-
Combination of ionic liquid-based dispersive liquid-liquid micro-extraction with stopped-flow spectrofluorometry for the pre-concentration and determination of aluminum in natural waters, fruit juice and food samples
-
Abdolmohammad-Zadeh H, Sadeghi GH (2010) Combination of ionic liquid-based dispersive liquid-liquid micro-extraction with stopped-flow spectrofluorometry for the pre-concentration and determination of aluminum in natural waters, fruit juice and food samples. Talanta 81: 778-785.
-
(2010)
Talanta
, vol.81
, pp. 778-785
-
-
Abdolmohammad-Zadeh, H.1
Sadeghi, G.H.2
-
31
-
-
77953362140
-
Development of a robust ionic liquid-based dispersive liquid-liquid microextraction against high concentration of salt for preconcentration of trace metals in saline aqueous samples: application to the determination of Pb and Cd
-
Yousefi SR, Shemirani F (2010) Development of a robust ionic liquid-based dispersive liquid-liquid microextraction against high concentration of salt for preconcentration of trace metals in saline aqueous samples: application to the determination of Pb and Cd. Anal Chim Acta 669: 25-31.
-
(2010)
Anal Chim Acta
, vol.669
, pp. 25-31
-
-
Yousefi, S.R.1
Shemirani, F.2
-
32
-
-
37249019196
-
Temperature-controlled ionic liquid dispersive liquid phase micro-extraction
-
Zhou QX, Bai HH, Xie GH, Xiao JP (2008) Temperature-controlled ionic liquid dispersive liquid phase micro-extraction. J Chromatogr A 1177: 43-49.
-
(2008)
J Chromatogr A
, vol.1177
, pp. 43-49
-
-
Zhou, Q.X.1
Bai, H.H.2
Xie, G.H.3
Xiao, J.P.4
-
33
-
-
78651314849
-
Determination of benzoic acid in water samples by ionic liquid cold-Induced aggregation dispersive LLME coupling with LC
-
Zhang H, Cheng M, Jiang X (2010) Determination of benzoic acid in water samples by ionic liquid cold-Induced aggregation dispersive LLME coupling with LC. Chromatographia 72: 1195-1199.
-
(2010)
Chromatographia
, vol.72
, pp. 1195-1199
-
-
Zhang, H.1
Cheng, M.2
Jiang, X.3
-
34
-
-
78650171498
-
Optimization of dispersive liquid-liquid microextraction coupled with inductively coupled plasma-optical emission spectrometry with the aid of experimental design for simultaneous determination of heavy metals in natural waters
-
Sereshti H, Khojeh V, Samadi S (2011) Optimization of dispersive liquid-liquid microextraction coupled with inductively coupled plasma-optical emission spectrometry with the aid of experimental design for simultaneous determination of heavy metals in natural waters. Talanta 83: 885-890.
-
(2011)
Talanta
, vol.83
, pp. 885-890
-
-
Sereshti, H.1
Khojeh, V.2
Samadi, S.3
-
35
-
-
75749110644
-
Solidified floating organic drop microextraction for determination of trace amounts of zinc in water samples by flame atomic absorption spectrometry
-
Ma J, Zhang J, Du X, Lei X, Li J (2010) Solidified floating organic drop microextraction for determination of trace amounts of zinc in water samples by flame atomic absorption spectrometry. Microchim Acta 168: 153-159.
-
(2010)
Microchim Acta
, vol.168
, pp. 153-159
-
-
Ma, J.1
Zhang, J.2
Du, X.3
Lei, X.4
Li, J.5
-
36
-
-
18844426583
-
Solid phase extraction and flame atomic absorption spectrometric determination of trace amounts of zinc and cobalt ions in water samples
-
Yamini Y, Hosseini MH, Morsali A (2004) Solid phase extraction and flame atomic absorption spectrometric determination of trace amounts of zinc and cobalt ions in water samples. Microchim Acta 146: 67-72.
-
(2004)
Microchim Acta
, vol.146
, pp. 67-72
-
-
Yamini, Y.1
Hosseini, M.H.2
Morsali, A.3
-
37
-
-
70349403768
-
Simultaneous preconcentration of copper, zinc, cadmium, and nickel in water samples by cloud point extraction using 4-(2-pyridylazo)-resorcinol and their determination by inductively coupled plasma optic emission spectrometry
-
Silva EL, Roldan PDS, Gine MF (2009) Simultaneous preconcentration of copper, zinc, cadmium, and nickel in water samples by cloud point extraction using 4-(2-pyridylazo)-resorcinol and their determination by inductively coupled plasma optic emission spectrometry. J Hazard Mater 171: 1133-1138.
-
(2009)
J Hazard Mater
, vol.171
, pp. 1133-1138
-
-
Silva, E.L.1
Roldan, P.D.S.2
Gine, M.F.3
|