메뉴 건너뛰기




Volumn 500, Issue , 2011, Pages 457-508

How to obtain true and accurate rate-values

Author keywords

Chemostat; Compound balance; Data reconciliation; Experimental pitfalls; q Rate

Indexed keywords

CARBON DIOXIDE; OXYGEN;

EID: 80053066884     PISSN: 00766879     EISSN: 15577988     Source Type: Book Series    
DOI: 10.1016/B978-0-12-385118-5.00023-2     Document Type: Chapter
Times cited : (3)

References (11)
  • 1
    • 0030128998 scopus 로고    scopus 로고
    • Data reconciliation - Progress and challenges
    • C.M. Crowe Data reconciliation - Progress and challenges J. Process Cont. 6 2-3 spec. 1996 89 98 (Pubitemid 126350773)
    • (1996) Journal of Process Control , vol.6 , Issue.2-3 SPEC. ISS. , pp. 89-98
    • Crowe, C.M.1
  • 2
    • 0020843611 scopus 로고
    • Reconciliation of process flow rates by matrix projection
    • C.M. Crowe, and Y.A.G. Campos Reconciliation of process flow rates by matrix projection. Part I: Linear case AIChE. J. 29 6 1983 881 888 (Pubitemid 14488611)
    • (1983) AIChE Journal , vol.29 , Issue.6 , pp. 881-888
    • Crowe, C.M.1    Campos Y.A.Garcia2    Hrymak, A.3
  • 3
    • 0018576817 scopus 로고
    • Application of balancing methods in modeling the penicillin fermentation
    • J.J. Heijnen, and J.A. Roels Application of balancing methods in modeling the penicillin fermentation Biotechnol. Bioeng. 21 12 1979 2175 2201 (Pubitemid 10142834)
    • (1979) Biotechnology and Bioengineering , vol.21 , Issue.12 , pp. 2175-2201
    • Heijnen, J.J.1    Roels, J.A.2    Stouthamer, A.H.3
  • 4
    • 84890161096 scopus 로고    scopus 로고
    • Process monitoring and data reconciliation
    • L. Puigjaner, G. Heyen, Wiley-VCH Weinheim
    • G. Heyen, and B. Kalitvenzeff Process monitoring and data reconciliation L. Puigjaner, G. Heyen, Computer Aided Process and Product Engineering 2007 Wiley-VCH Weinheim 517 539
    • (2007) Computer Aided Process and Product Engineering , pp. 517-539
    • Heyen, G.1    Kalitvenzeff, B.2
  • 5
    • 0025778993 scopus 로고
    • The bioreactor overflow device: An undesired selective separator in continuous cultures?
    • H.J. Noorman, and J. Baksteen The bioreactor overflow device: An undesired selective separator in continuous cultures? J. Gen. Microbiol. 137 9 1991 2171 2177
    • (1991) J. Gen. Microbiol. , vol.137 , Issue.9 , pp. 2171-2177
    • Noorman, H.J.1    Baksteen, J.2
  • 7
    • 58349085312 scopus 로고    scopus 로고
    • Development and application of a differential method for reliable metabolome analysis in Escherichia coli
    • H. Taymaz-Nikerel, and M. de Mey Development and application of a differential method for reliable metabolome analysis in Escherichia coli Anal. Biochem. 386 1 2009 9 19
    • (2009) Anal. Biochem. , vol.386 , Issue.1 , pp. 9-19
    • Taymaz-Nikerel, H.1    De Mey, M.2
  • 8
    • 78149245282 scopus 로고    scopus 로고
    • Genome-derived minimal metabolic models for Escherichia coli MG1655 with estimated in vivo respiratory ATP stoichiometry
    • H. Taymaz-Nikerel, and A.E. Borujeni Genome-derived minimal metabolic models for Escherichia coli MG1655 with estimated in vivo respiratory ATP stoichiometry Biotechnol. Bioeng. 107 2 2010 369 381
    • (2010) Biotechnol. Bioeng. , vol.107 , Issue.2 , pp. 369-381
    • Taymaz-Nikerel, H.1    Borujeni, A.E.2
  • 9
    • 0028764687 scopus 로고
    • Linear constraint relations in biochemical reaction systems: I. Classification of the calculability and the balanceability of conversion rates
    • DOI 10.1002/bit.260430103
    • R.T.J.M. Van Der Heijden, and J.J. Heijnen Linear constraint relations in biochemical reaction systems: I. Classification of the calculability and the balanceability of conversion rates Biotechnol. Bioeng. 43 1 1994 3 10 (Pubitemid 24001731)
    • (1994) Biotechnology and Bioengineering , vol.43 , Issue.1 , pp. 3-10
    • Van Der Heijden, R.T.J.M.1    Heijnen, J.J.2    Hellinga, C.3    Romein, B.4    Luyben, K.C.A.M.5
  • 11
    • 0020812944 scopus 로고
    • Application of macroscopic balances to the identification of gross measurement errors
    • N.S. Wang, and G. Stephanopoulos Application of macroscopic balances to the identification of gross measurement errors Biotechnol. Bioeng. 25 9 1983 2177 2208 (Pubitemid 14526831)
    • (1983) Biotechnology and Bioengineering , vol.25 , Issue.9 , pp. 2177-2208
    • Wang, N.S.1    Stephanopoulos, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.