메뉴 건너뛰기




Volumn 93, Issue SUPPL. 2, 2011, Pages 84-88

Evolution in hip resurfacing design and contemporary experience with an uncemented device

Author keywords

[No Author keywords available]

Indexed keywords

BISMUTH; METAL ION;

EID: 80052930296     PISSN: 00219355     EISSN: 15351386     Source Type: Journal    
DOI: 10.2106/JBJS.J.01716     Document Type: Article
Times cited : (13)

References (15)
  • 1
    • 0029810740 scopus 로고    scopus 로고
    • Metal on metal surface replacement of the hip. Experience of the McMinn prosthesis
    • McMinn D, Treacy R, Lin K, Pynsent P.Metal on metal surface replacement of the hip. Experience of the McMinn prosthesis. Clin Orthop Relat Res. 1996;329 Suppl:S89-98.
    • (1996) Clin Orthop Relat Res , vol.329 , Issue.SUPPL.
    • McMinn, D.1    Treacy, R.2    Lin, K.3    Pynsent, P.4
  • 2
    • 84873546382 scopus 로고    scopus 로고
    • Cormet Hip Resurfacing System-P050016. Jul 3; updated 2007 Aug 21. Accessed 2007 Nov 21
    • Cormet Hip Resurfacing System-P050016. Summary of safety and effectiveness. 2007 Jul 3; updated 2007 Aug 21. http://www.accessdata.fda.gov/ cdrh-docs/pdf5/P050016b.pdf. Accessed 2007 Nov 21.
    • (2007) Summary of Safety and Effectiveness
  • 3
    • 33645239883 scopus 로고    scopus 로고
    • 'Severe' wear challenge to 'ascast' and 'double heat-treated' large-diameter metal-on-metal hip bearings
    • Bowsher JG, Nevelos J, Williams PA, Shelton JC. 'Severe' wear challenge to 'ascast' and 'double heat-treated' large-diameter metal-on-metal hip bearings. Proc Inst Mech Eng H. 2006;220:135-43.
    • (2006) Proc Inst Mech Eng H , vol.220 , pp. 135-143
    • Bowsher, J.G.1    Nevelos, J.2    Williams, P.A.3    Shelton, J.C.4
  • 4
    • 33645218204 scopus 로고    scopus 로고
    • History and modern concepts in surface replacement
    • McMinn D, Daniel J. History and modern concepts in surface replacement. Proc Inst Mech Eng H. 2006;220:239-51.
    • (2006) Proc Inst Mech Eng H , vol.220 , pp. 239-251
    • McMinn, D.1    Daniel, J.2
  • 9
    • 17044433022 scopus 로고    scopus 로고
    • Hydroxyapatite-coated femoral implant in metal-on- metal resurfacing hip arthroplasty: Minimum of two years follow-up
    • Lilikakis AK, Vowler SL, Villar RN. Hydroxyapatite-coated femoral implant in metal-on- metal resurfacing hip arthroplasty: minimum of two years follow-up. Orthop Clin North Am. 2005;36:215-22, ix.
    • (2005) Orthop Clin North Am , vol.36
    • Lilikakis, A.K.1    Vowler, S.L.2    Villar, R.N.3
  • 13
    • 78650100740 scopus 로고    scopus 로고
    • Metal ion levels following resurfacing arthroplasty of the hip: Serial results over a ten-year period
    • deSouza RM, Parsons NR, Oni T, Dalton P, Costa M, Krikler S. Metal ion levels following resurfacing arthroplasty of the hip: serial results over a ten-year period. J Bone Joint Surg Br. 2010;92:1642-7.
    • (2010) J Bone Joint Surg Br , vol.92 , pp. 1642-1647
    • DeSouza, R.M.1    Parsons, N.R.2    Oni, T.3    Dalton, P.4    Costa, M.5    Krikler, S.6
  • 14
    • 34047242914 scopus 로고    scopus 로고
    • Serum cobalt and chromium elevations following hip resurfacing with the Cormet 2000 device
    • Allan DG, Trammell R, Dyrstad B, Barnhart B, Milbrandt JC. Serum cobalt and chromium elevations following hip resurfacing with the Cormet 2000 device. J Surg Orthop Adv. 2007;16:12-8.
    • (2007) J Surg Orthop Adv , vol.16 , pp. 12-18
    • Allan, D.G.1    Trammell, R.2    Dyrstad, B.3    Barnhart, B.4    Milbrandt, J.C.5