메뉴 건너뛰기




Volumn 10, Issue , 2011, Pages 1955-1960

Microscopic analysis of fractured dental implant surface after clinical use

Author keywords

Abutment screw; Dental implant; Fatigue fracture; Fatigue striation; FE SEM

Indexed keywords

BRITTLE FRACTURE; CORROSION RESISTANCE; FATIGUE OF MATERIALS; FIXTURES (TOOLING); FRACTURE; SCANNING ELECTRON MICROSCOPY; SCREWS; ULTRASONIC CLEANING;

EID: 80052917511     PISSN: 18777058     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1016/j.proeng.2011.04.324     Document Type: Conference Paper
Times cited : (11)

References (21)
  • 1
    • 0025471133 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants: The toronto study. Part III. Problems and complication encountered
    • Rangert Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III. Problems and complication encountered. J Prosthet Dent 1990; 64:185-94.
    • (1990) J Prosthet Dent , vol.64 , pp. 185-194
    • Rangert Zarb, G.A.1    Schmitt, A.2
  • 4
    • 0030141079 scopus 로고    scopus 로고
    • Use of wide implants and double implants in the posterior jaw: A clinical report
    • Bahat O. Handelsman M. Use of wide implants and double implants in the posterior jaw: a clinical report. Int J Oral Maxillofac Implants 1996; 11:379-86
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 379-386
    • Bahat, O.1    Handelsman, M.2
  • 6
    • 80052947272 scopus 로고    scopus 로고
    • A study on surface alternation of implant screws after function
    • Han MJ, Chung CH, Choi HC. A study on surface alternation of implant screws after function. J Korean Acad Prosthodont 2002; 40:275-86
    • (2002) J Korean Acad Prosthodont , vol.40 , pp. 275-286
    • Han, M.J.1    Chung, C.H.2    Choi, H.C.3
  • 7
    • 0026832538 scopus 로고
    • Failures and complications in 127 consecutively placed fixed partial prostheses supported by brånemak implants: From prosthetic treatment to first annual chekup
    • Jemt T, Lindén B, Lekholm U. Failures and complications in 127 consecutively placed fixed partial prostheses supported by Brånemak implants: from prosthetic treatment to first annual chekup. Int J Oral Maxillofac Implants 1992; 7:40-4
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 40-44
    • Jemt, T.1    Lindén, B.2    Lekholm, U.3
  • 11
    • 0026834154 scopus 로고
    • Retrieval analyses of a blade implant after 231 months of clinical function
    • Linkow LI, Donath K, Lemons JE. Retrieval analyses of a blade implant after 231 months of clinical function. Implant Dent 1992; 1:37-43
    • (1992) Implant Dent , vol.1 , pp. 37-43
    • Linkow, L.I.1    Donath, K.2    Lemons, J.E.3
  • 14
    • 11144267884 scopus 로고    scopus 로고
    • Analyses of fracutred implant fixture after prolonged implantation
    • Choe HC, Lee JK, Chung CH. Analyses of fracutred implant fixture after prolonged implantation. Met Mater Int 2004; 10:327-35
    • (2004) Met Mater Int , vol.10 , pp. 327-335
    • Choe, H.C.1    Lee, J.K.2    Chung, C.H.3
  • 16
    • 68949146669 scopus 로고
    • Comparative surface analysis and clinical performance studies of brånemark implants and related clones
    • A. Helsingen, T. Lyberg, Comparative surface analysis and clinical performance studies of Brånemark implants and related clones. Int J Oral Maxillofac Implnats 1994; 9:422-30
    • (1994) Int J Oral Maxillofac Implnats , vol.9 , pp. 422-430
    • Helsingen, A.1    Lyberg, T.2
  • 17
    • 0034574104 scopus 로고    scopus 로고
    • Mechanical complications of dental implants
    • Schwarz MS. Mechanical complications of dental implants. Clin Oral Impl Res 2000; 11 (Suppl.); 156-8
    • (2000) Clin Oral Impl Res , vol.11 , Issue.SUPPL. , pp. 156-158
    • Schwarz, M.S.1
  • 18
    • 0028185281 scopus 로고
    • Osseointegrated implants for single-tooth replacement: Progress report from a multicenter prospective study after 3 years
    • W. Laney, T. Jemt, and D. Harris. Osseointegrated implants for single-tooth replacement: progress report from a multicenter prospective study after 3 years. Int J Oral Maxillofac Implants 1994; 9:49-54
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 49-54
    • Laney, W.1    Jemt, T.2    Harris, D.3
  • 19
    • 0026829920 scopus 로고
    • Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants
    • Patterson EA, Johns RB. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants 1992; 7; 26-34
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 26-34
    • Patterson, E.A.1    Johns, R.B.2
  • 20
    • 0031989688 scopus 로고    scopus 로고
    • Hollow implants retrieved for fracture:A light and scanning electron microscope analysis of 4 cases
    • Piattelli A, Scarano A, Piattelli m, Vaiva E, Matarasso S. Hollow implants retrieved for fracture:a light and scanning electron microscope analysis of 4 cases. J Periodontol 1998; 69(2):185-9
    • (1998) J Periodontol , vol.69 , Issue.2 , pp. 185-189
    • Piattelli, A.1    Scarano, A.2    Piattelli, M.3    Vaiva, E.4    Matarasso, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.