메뉴 건너뛰기




Volumn 22, Issue 9, 2011, Pages 1007-1012

Randomized comparison of cavotricuspid isthmus ablation for atrial flutter using an open irrigation-tip versus a large-tip radiofrequency ablation catheter

Author keywords

atrial flutter; catheter ablation; cavotricuspid isthmus; irrigated tip catheter; monitoring

Indexed keywords

INFUSION FLUID;

EID: 80052841264     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2011.02045.x     Document Type: Article
Times cited : (25)

References (21)
  • 2
    • 0027534580 scopus 로고
    • Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter
    • DOI 10.1016/0002-9149(93)91014-9
    • Cosio FG, Lopez-Gil M, Goicolea A, Arribas F, Barroso JL,: Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter. Am J Cardiol 1993; 71: 705-709. (Pubitemid 23085822)
    • (1993) American Journal of Cardiology , vol.71 , Issue.8 , pp. 705-709
    • Cosio, F.G.1    Lopez-Gil, M.2    Goicolea, A.3    Arribas, F.4    Barroso, J.L.5
  • 3
    • 13544262681 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation of Type 1 atrial flutter using a large-tip electrode catheter and high-power radiofrequency energy generator
    • DOI 10.1586/17434440.1.2.187
    • Feld GK,: Radiofrequency catheter ablation of type 1 atrial flutter using a large-tip electrode catheter and high-power radiofrequency energy generator. Expert Rev Med Devices 2004; 1: 187-192. (Pubitemid 40220431)
    • (2004) Expert Review of Medical Devices , vol.1 , Issue.2 , pp. 187-192
    • Feld, G.K.1
  • 6
    • 3042835885 scopus 로고    scopus 로고
    • Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter
    • DOI 10.1016/j.ehj.2004.03.017, PII S0195668X04002027
    • Scavee C, Jais P, Hsu LF, Sanders P, Hocini M, Weerasooriya R, Macle L, Raybaud F, Clementy J, Haissaguerre M,: Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter. Eur Heart J 2004; 25: 963-969. (Pubitemid 38857870)
    • (2004) European Heart Journal , vol.25 , Issue.11 , pp. 963-969
    • Scavee, C.1    Jais, P.2    Hsu, L.-F.3    Sanders, P.4    Hocini, M.5    Weerasooriya, R.6    Macle, L.7    Raybaud, F.8    Clementy, J.9    Haissaguerre, M.10
  • 7
    • 4844229375 scopus 로고    scopus 로고
    • Effect of isthmus anatomy and ablation catheter on radiofrequency catheter ablation of the cavotricuspid isthmus
    • DOI 10.1161/01.CIR.0000139845.40818.75
    • Da Costa A, Faure E, Thevenin J, Messier M, Bernard S, Abdel K, Robin C, Romeyer C, Isaaz K,: Effect of isthmus anatomy and ablation catheter on radiofrequency catheter ablation of the cavotricuspid isthmus. Circulation 2004; 110: 1030-1035. (Pubitemid 39318998)
    • (2004) Circulation , vol.110 , Issue.9 , pp. 1030-1035
    • Da Costa, A.1    Faure, E.2    Thevenin, J.3    Messier, M.4    Bernard, S.5    Abdel, K.6    Robin, C.7    Romeyer, C.8    Isaaz, K.9
  • 8
    • 0342470431 scopus 로고    scopus 로고
    • Prospective randomized comparison of irrigated-tip versus conventional- tip catheters for ablation of common flutter
    • Jais P, Shah DC, Haissaguerre M, Hocini M, Garrigue S, Le Metayer P, Clementy J,: Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter. Circulation 2000; 101: 772-776. (Pubitemid 30100084)
    • (2000) Circulation , vol.101 , Issue.7 , pp. 772-776
    • Jais, P.1    Shah, D.C.2    Haissaguerre, M.3    Hocini, M.4    Garrigue, S.5    Le Metayer, P.6    Clementy, J.7
  • 9
    • 0034332724 scopus 로고    scopus 로고
    • Comparison of effectiveness of an 8-mm versus a 4-mm tip electrode catheter for radiofrequency ablation of typical atrial flutter
    • A1010.
    • Kasai A, Anselme F, Teo WS, Cribier A, Saoudi N,: Comparison of effectiveness of an 8-mm versus a 4-mm tip electrode catheter for radiofrequency ablation of typical atrial flutter. Am J Cardiol 2000; 86: 1029-1032, A1010.
    • (2000) Am J Cardiol , vol.86 , pp. 1029-1032
    • Kasai, A.1    Anselme, F.2    Teo, W.S.3    Cribier, A.4    Saoudi, N.5
  • 11
    • 65349173592 scopus 로고    scopus 로고
    • Radiofrequency catheter selection based on cavotricuspid angiography compared with a control group with an externally cooled-tip catheter: A randomized pilot study
    • Da Costa A, Romeyer-Bouchard C, Jamon Y, Bisch L, Isaaz K,: Radiofrequency catheter selection based on cavotricuspid angiography compared with a control group with an externally cooled-tip catheter: A randomized pilot study. J Cardiovasc Electrophysiol 2009; 20: 492-498.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 492-498
    • Da Costa, A.1    Romeyer-Bouchard, C.2    Jamon, Y.3    Bisch, L.4    Isaaz, K.5
  • 12
    • 33748036367 scopus 로고    scopus 로고
    • Cavotricuspid isthmus angiography predicts atrial flutter ablation efficacy in 281 patients randomized between 8 mm- and externally irrigated-tip catheter
    • DOI 10.1093/eurheartj/ehl121
    • Da Costa A, Romeyer-Bouchard C, Dauphinot V, Lipp D, Abdellaoui L, Messier M, Thevenin J, Barthelemy JC, Isaaz K,: Cavotricuspid isthmus angiography predicts atrial flutter ablation efficacy in 281 patients randomized between 8 mm- and externally irrigated-tip catheter. Eur Heart J 2006; 27: 1833-1840. (Pubitemid 44297390)
    • (2006) European Heart Journal , vol.27 , Issue.15 , pp. 1833-1840
    • Da Costa, A.1    Romeyer-Bouchard, C.2    Dauphinot, V.3    Lipp, D.4    Abdellaoui, L.5    Messier, M.6    Thevenin, J.7    Barthelemy, J.-C.8    Isaaz, K.9
  • 13
    • 0031795163 scopus 로고    scopus 로고
    • The architecture of the atrial musculature between the orifice of the inferior caval vein and the tricuspid valve: The anatomy of the isthmus
    • Cabrera JA, Sanchez-Quintana D, Ho SY, Medina A, Anderson RH,: The architecture of the atrial musculature between the orifice of the inferior caval vein and the tricuspid valve: The anatomy of the isthmus. J Cardiovasc Electrophysiol 1998; 9: 1186-1195. (Pubitemid 28516147)
    • (1998) Journal of Cardiovascular Electrophysiology , vol.9 , Issue.11 , pp. 1186-1195
    • Cabrera, J.A.1    Sanchez-Quintana, D.2    Ho, S.Y.3    Medina, A.4    Anderson, R.H.5
  • 14
    • 67649497555 scopus 로고    scopus 로고
    • Effect of electroanatomically guided versus conventional catheter ablation of typical atrial flutter on the fluoroscopy time and resource use: A prospective randomized multicenter study
    • Hindricks G, Willems S, Kautzner J, De Chillou C, Wiedemann M, Schepel S, Piorkowski C, Risius T, Kottkamp H,: Effect of electroanatomically guided versus conventional catheter ablation of typical atrial flutter on the fluoroscopy time and resource use: A prospective randomized multicenter study. J Cardiovasc Electrophysiol 2009; 20: 734-740.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 734-740
    • Hindricks, G.1    Willems, S.2    Kautzner, J.3    De Chillou, C.4    Wiedemann, M.5    Schepel, S.6    Piorkowski, C.7    Risius, T.8    Kottkamp, H.9
  • 15
    • 2442480299 scopus 로고    scopus 로고
    • Randomized comparison of anatomical versus voltage guided ablation of the cavotricuspid isthmus for atrial flutter
    • DOI 10.1016/j.hrthm.2004.01.004, PII S154752710400013X
    • Hall B, Veerareddy S, Cheung P, Good E, Lemola K, Han J, Kamala T, Chugh A, Pelosi F Jr, Morady F, Oral H,: Randomized comparison of anatomical versus voltage guided ablation of the cavotricuspid isthmus for atrial flutter. Heart Rhythm 2004; 1: 43-48. (Pubitemid 38647248)
    • (2004) Heart Rhythm , vol.1 , Issue.1 , pp. 43-48
    • Hall, B.1    Veerareddy, S.2    Cheung, P.3    Good, E.4    Lemola, K.5    Han, J.6    Kamala, T.7    Chugh, A.8    Pelosi Jr., F.9    Morady, F.10    Oral, H.11
  • 16
    • 0028942447 scopus 로고
    • Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
    • Nakagawa H, Yamanashi WS, Pitha JV, Arruda M, Wang X, Ohtomo K, Beckman KJ, McClelland JH, Lazzara R, Jackman WM,: Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995; 91: 2264-2273.
    • (1995) Circulation , vol.91 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.S.2    Pitha, J.V.3    Arruda, M.4    Wang, X.5    Ohtomo, K.6    Beckman, K.J.7    McClelland, J.H.8    Lazzara, R.9    Jackman, W.M.10
  • 20
    • 23744475227 scopus 로고    scopus 로고
    • Radiofrequency ablation for common atrial flutter using an 8-mm tip catheter and up to 150W
    • DOI 10.1016/j.eupc.2005.03.002, PII S1099512905001741
    • Hillock RJ, Melton IC, Crozier IG,: Radiofrequency ablation for common atrial flutter using an 8-mm tip catheter and up to 150 W. Europace 2005; 7: 409-412. (Pubitemid 41122265)
    • (2005) Europace , vol.7 , Issue.5 , pp. 409-412
    • Hillock, R.J.1    Melton, I.C.2    Crozier, I.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.