메뉴 건너뛰기




Volumn , Issue , 2011, Pages 631-636

Investigations on sensitivity of FRA method in diagnosis of interturn faults in transformer winding

Author keywords

[No Author keywords available]

Indexed keywords

FRA METHOD; FREQUENCY RESPONSE ANALYSIS; INTER-TURN FAULT; IRON CORES; MAGNITUDE SPECTRUM; REDUCED SCALE; SHORTED TURNS; TRACTION TRANSFORMER; WAVE FORMS;

EID: 80052840483     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISIE.2011.5984231     Document Type: Conference Paper
Times cited : (11)

References (7)
  • 1
    • 0018038144 scopus 로고
    • Transformer diagnostic testing by frequency response analysis
    • Nov.
    • E.P. Dick, C.C. Erven, "Transformer diagnostic testing by frequency response analysis," IEEE Transactions on Power Appl. Systems, vol. PAS-97, No-6, Nov. 1978, pp. 2144-2153.
    • (1978) IEEE Transactions on Power Appl. Systems , vol.PAS-97 , Issue.6 , pp. 2144-2153
    • Dick, E.P.1    Erven, C.C.2
  • 2
    • 0037667689 scopus 로고    scopus 로고
    • Diagnosing transformer faults using frequency response analysis
    • March/April
    • S.A. Ryder, "Diagnosing transformer faults using frequency response analysis," IEEE Electrical Insulation magazine, vol. 19, No. 2, pp. 16-22, March/April 2003.
    • (2003) IEEE Electrical Insulation Magazine , vol.19 , Issue.2 , pp. 16-22
    • Ryder, S.A.1
  • 3
    • 84954429870 scopus 로고    scopus 로고
    • Detection of shorted turns and winding movements in large power transformers using frequency response analysis
    • Jan., Singapure
    • S. Islam, "Detection of shorted turns and winding movements in large power transformers using frequency response analysis," IEEE PES winter meeting, vol. 3, pp. 2233-2238, Jan. 2327, 2000, Singapure.
    • (2000) IEEE PES Winter Meeting , vol.3 , Issue.2327 , pp. 2233-2238
    • Islam, S.1
  • 5
    • 84861522153 scopus 로고    scopus 로고
    • A new development in power transformer frequency response analysis to determine winding deformation without the need for comparison to historical data
    • Feb. 17-20, San Antonio
    • L. Coffen, J. Hildreth, "A new development in power transformer frequency response analysis to determine winding deformation without the need for comparison to historical data," Proc. of the 2002 EPRI Substation Equipment Diagnostics Conference X, Feb. 17-20, San Antonio, 2002.
    • (2002) Proc. of the 2002 EPRI Substation Equipment Diagnostics Conference X
    • Coffen, L.1    Hildreth, J.2
  • 7
    • 50249181070 scopus 로고    scopus 로고
    • Application of numerical evaluation techniques for interpreting frequency response measurements in power transformers
    • P.M. Nirgude, D. Ashokraju, A.D. Rajkumar, B.P. Singh, "Application of numerical evaluation techniques for interpreting frequency response measurements in power transformers," IET Sci. Meas. Technol., 2008, Vol. 2, No. 5, pp. 275-285.
    • (2008) IET Sci. Meas. Technol. , vol.2 , Issue.5 , pp. 275-285
    • Nirgude, P.M.1    Ashokraju, D.2    Rajkumar, A.D.3    Singh, B.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.