메뉴 건너뛰기




Volumn 46, Issue 9, 2011, Pages 943-948

Development and validation of a high-performance liquid chromatography-electrospray ionization-MS/MS method for the simultaneous quantitation of levodopa and carbidopa in human plasma

Author keywords

carbidopa HPLC ESI MS MS; levodopa; pharmacokinetics; plasma

Indexed keywords

CARBIDOPA; ELECTROSPRAY SOURCE; HPLC-ESI-MS/MS; HUMAN PLASMAS; INTERNAL STANDARDS; ION TRANSITION; LEVODOPA; METHYLDOPA; MOBILE PHASE; PERCHLORIC ACIDS; PHARMACOKINETIC STUDIES; POSITIVE MODE; PROTEIN PRECIPITATION; SELECTIVE REACTION MONITORING; TABLET FORMULATIONS; TRIPLE-QUADRUPOLE MASS SPECTROMETER;

EID: 80052790907     PISSN: 10765174     EISSN: 10969888     Source Type: Journal    
DOI: 10.1002/jms.1973     Document Type: Article
Times cited : (35)

References (16)
  • 1
    • 33344469306 scopus 로고    scopus 로고
    • Pharmacokinetic optimisation in the treatment of Parkinson's disease
    • D. Nyholm,. Pharmacokinetic optimisation in the treatment of Parkinson's disease. Clin. Pharmacokinet. 2006, 45, 109.
    • (2006) Clin. Pharmacokinet. , vol.45 , pp. 109
    • Nyholm, D.1
  • 2
    • 66949117423 scopus 로고    scopus 로고
    • The scientific and clinical basis for the treatment of Parkinson disease (2009)
    • C.W. Olanow, M.B. Stern, K. Sethi,. The scientific and clinical basis for the treatment of Parkinson disease (2009). Neurology. 2009, 72, S1.
    • (2009) Neurology , vol.72
    • Olanow, C.W.1    Stern, M.B.2    Sethi, K.3
  • 3
    • 77951278327 scopus 로고    scopus 로고
    • Levodopa/carbidopa and entacapone in the treatment of Parkinson's disease: Efficacy, safety and patient preference
    • T. Muller,. Levodopa/carbidopa and entacapone in the treatment of Parkinson's disease: efficacy, safety and patient preference. Patient Prefer. Adherence 2009, 3, 51.
    • (2009) Patient Prefer. Adherence , vol.3 , pp. 51
    • Muller, T.1
  • 4
    • 77952430396 scopus 로고    scopus 로고
    • Direct switch from levodopa/benserazide or levodopa/carbidopa to levodopa/carbidopa/entacapone in Parkinson's disease patients with wearing-off: Efficacy, safety and feasibility - An open-label, 6-week study
    • K. Eggert, O. Skogar, K. Amar, L. Luotonen, M. Kuoppamaki, M. Leinonen, H. Nissinen, W. Oertel,. Direct switch from levodopa/benserazide or levodopa/carbidopa to levodopa/carbidopa/entacapone in Parkinson's disease patients with wearing-off: efficacy, safety and feasibility-an open-label, 6-week study. J. Neural Transm. 2010, 117, 333.
    • (2010) J. Neural Transm. , vol.117 , pp. 333
    • Eggert, K.1    Skogar, O.2    Amar, K.3    Luotonen, L.4    Kuoppamaki, M.5    Leinonen, M.6    Nissinen, H.7    Oertel, W.8
  • 6
    • 0023637175 scopus 로고
    • Inhibition of decarboxylase and levels of dopa and 3-Omethyldopa: A comparative study of benserazide versus carbidopa in rodents and of Madopar standard versus Madopar HBS in volunteers
    • M. Da Prada, R. Kettler, G. Zurcher, R. Shaffner, W.E. Haefely,. Inhibition of decarboxylase and levels of dopa and 3-Omethyldopa: a comparative study of benserazide versus carbidopa in rodents and of Madopar standard versus Madopar HBS in volunteers. Eur. Neurol. 1987, 27, 9.
    • (1987) Eur. Neurol. , vol.27 , pp. 9
    • Da Prada, M.1    Kettler, R.2    Zurcher, G.3    Shaffner, R.4    Haefely, W.E.5
  • 8
    • 0034126257 scopus 로고    scopus 로고
    • Bioavailability studies of oral dosage forms containing levodopa and carbidopa using column-switching chromatography followed by electrochemical detection
    • K.A. Sagar, M.R. Smyth,. Bioavailability studies of oral dosage forms containing levodopa and carbidopa using column-switching chromatography followed by electrochemical detection. Analyst 2000, 125, 439.
    • (2000) Analyst , vol.125 , pp. 439
    • Sagar, K.A.1    Smyth, M.R.2
  • 9
    • 0034064565 scopus 로고    scopus 로고
    • Simultaneous determination of levodopa, carbidopa and their metabolites in human plasma and urine samples using LC-EC
    • K.A. Sagar, M.R. Smyth,. Simultaneous determination of levodopa, carbidopa and their metabolites in human plasma and urine samples using LC-EC. J. Pharm. Biomed. Anal. 2000, 22, 613.
    • (2000) J. Pharm. Biomed. Anal. , vol.22 , pp. 613
    • Sagar, K.A.1    Smyth, M.R.2
  • 10
    • 33646253888 scopus 로고    scopus 로고
    • Modified high-performance liquid chromatography with electrochemical detection method for plasma measurement of levodopa, 3-O-methyldopa, dopamine, carbidopa and 3,4-dihydroxyphenyl acetic acid
    • M. Karimi, J.L. Carl, S. Loftin, J.S. Perlmutter,. Modified high-performance liquid chromatography with electrochemical detection method for plasma measurement of levodopa, 3-O-methyldopa, dopamine, carbidopa and 3,4-dihydroxyphenyl acetic acid. J. Chromatogr. B 2006, 836, 120.
    • (2006) J. Chromatogr. B , vol.836 , pp. 120
    • Karimi, M.1    Carl, J.L.2    Loftin, S.3    Perlmutter, J.S.4
  • 11
    • 0026034997 scopus 로고
    • Simultaneous determination of levodopa, its main metabolites and carbidopa in plasma by liquid chromatography
    • T. Wikberg,. Simultaneous determination of levodopa, its main metabolites and carbidopa in plasma by liquid chromatography. J. Pharm. Biomed. Anal. 1991, 9, 167.
    • (1991) J. Pharm. Biomed. Anal. , vol.9 , pp. 167
    • Wikberg, T.1
  • 12
    • 0030756481 scopus 로고    scopus 로고
    • Automated determination of levodopa and carbidopa in plasma by high-performance liquid chromatography-electrochemical detection using an on-line flow injection analysis sample pretreatment unit
    • A. Tolokan, I. Klebovich, K. Balogh-Nemes, G. Horvai,. Automated determination of levodopa and carbidopa in plasma by high-performance liquid chromatography-electrochemical detection using an on-line flow injection analysis sample pretreatment unit. J. Chromatogr. B 1997, 698, 201.
    • (1997) J. Chromatogr. B , vol.698 , pp. 201
    • Tolokan, A.1    Klebovich, I.2    Balogh-Nemes, K.3    Horvai, G.4
  • 13
    • 0025633701 scopus 로고
    • Simultaneous high-performance liquid chromatographic analysis of carbidopa, levodopa and 3-O-methyldopa in plasma and carbidopa, levodopa and dopamine in urine using electrochemical detection
    • D.C. Titus, T.F. August, K.C. Yeh, R. Eisenhandler, W.F. Bayne, D.G. Musson,. Simultaneous high-performance liquid chromatographic analysis of carbidopa, levodopa and 3-O-methyldopa in plasma and carbidopa, levodopa and dopamine in urine using electrochemical detection. J. Chromatogr. B 1990, 534, 87.
    • (1990) J. Chromatogr. B , vol.534 , pp. 87
    • Titus, D.C.1    August, T.F.2    Yeh, K.C.3    Eisenhandler, R.4    Bayne, W.F.5    Musson, D.G.6
  • 14
    • 77949288102 scopus 로고    scopus 로고
    • Quantitative analysis of levodopa, carbidopa and methyldopa in human plasma samples using HPLC-DAD combined with second-order calibration based on alternating trilinear decomposition algorithm
    • S.F. Li, H.L. Wu, Y.J. Yu, Y.N. Li, J.F. Nie, H.Y. Fu, R.Q. Yu,. Quantitative analysis of levodopa, carbidopa and methyldopa in human plasma samples using HPLC-DAD combined with second-order calibration based on alternating trilinear decomposition algorithm. Talanta 2010, 81, 805.
    • (2010) Talanta , vol.81 , pp. 805
    • Li, S.F.1    Wu, H.L.2    Yu, Y.J.3    Li, Y.N.4    Nie, J.F.5    Fu, H.Y.6    Yu, R.Q.7
  • 15
    • 77954864483 scopus 로고    scopus 로고
    • Simultaneous determination of L-dopa and its prodrug (S)-4-(2-acetamido- 3-ethoxy-3-oxopropyl)-1,2-phenylene diacetate in rat plasma by high-performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
    • W. Jiang, L. Lv, S. Zhou, X. Huang, X. Shi, C. Lv, L. Wu, C. Xu,. Simultaneous determination of L-dopa and its prodrug (S)-4-(2-acetamido-3- ethoxy-3-oxopropyl)-1,2-phenylene diacetate in rat plasma by high-performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study. J. Pharm. Biomed. Anal. 2010, 53, 751.
    • (2010) J. Pharm. Biomed. Anal. , vol.53 , pp. 751
    • Jiang, W.1    Lv, L.2    Zhou, S.3    Huang, X.4    Shi, X.5    Lv, C.6    Wu, L.7    Xu, C.8
  • 16
    • 0038296381 scopus 로고    scopus 로고
    • Food and Drug Administration. U.S. Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research: Rockville.
    • Food and Drug Administration. FDA Guidance for Industry: Bioanalytical Method Validation. U.S. Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research: Rockville, 2001.
    • (2001) FDA Guidance for Industry: Bioanalytical Method Validation


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.