메뉴 건너뛰기




Volumn 34, Issue 7, 2011, Pages 1587-1595

Research on air-source heat pump coupled with economized vapor injection scroll compressor and ejector

Author keywords

Air source; Calculation; Design; Ejector; Heat pump; Injection; Scroll compressor

Indexed keywords

AIR-SOURCE; DESIGN METHOD; ENTRAINMENT RATIO; EVAPORATION TEMPERATURE; EXPERIMENTAL SETUP; HEAT PUMPS; HEATING CAPACITY; LOW TEMPERATURE CONDITIONS; MEASURED RESULTS; OPTIMAL LOCATIONS; REASONABLE VALUE; VAPOR INJECTION; WORKING CHAMBERS;

EID: 80052755141     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2010.06.003     Document Type: Article
Times cited : (46)

References (14)
  • 1
    • 34247562854 scopus 로고    scopus 로고
    • Effect of throat diameters of the ejector on the performance of the refrigeration cycle using a two-phase ejector as an expansion device
    • P. Chaiwongsa, and S. Wongwises Effect of throat diameters of the ejector on the performance of the refrigeration cycle using a two-phase ejector as an expansion device International Journal of Refrigeration 24 2007 1 8
    • (2007) International Journal of Refrigeration , vol.24 , pp. 1-8
    • Chaiwongsa, P.1    Wongwises, S.2
  • 2
    • 80052762962 scopus 로고    scopus 로고
    • Chinese national standards GB 5773-86, the standard for performance tests for positive displacement refrigerant compressors
    • Chinese national standards GB 5773-86, the standard for performance tests for positive displacement refrigerant compressors.
  • 3
    • 80052717570 scopus 로고    scopus 로고
    • Chinese national standards GB/T 9056-1999, the standard for performance tests for positive displacement refrigerant compressor condensing units
    • Chinese national standards GB/T 9056-1999, the standard for performance tests for positive displacement refrigerant compressor condensing units.
  • 4
    • 0037211454 scopus 로고    scopus 로고
    • Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor
    • DOI 10.1016/S0140-7007(02)00017-8, PII S0140700702000178
    • H. Cho, J.T. Chung, and Y. Kim Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor International Journal of Refrigeration 26 2003 87 94 (Pubitemid 35411899)
    • (2003) International Journal of Refrigeration , vol.26 , Issue.1 , pp. 87-94
    • Cho, H.1    Chung, J.T.2    Kim, Y.3
  • 6
    • 0035452618 scopus 로고    scopus 로고
    • An investigation of the performance of a scroll compressor under liquid refrigerant injection
    • DOI 10.1016/S0140-7007(00)00041-4, PII S0140700700000414
    • A.K. Dutta, T. Yanagisawa, and M. Fukuta An investigation of the performance of a scroll compressor under liquid refrigerant injection International Journal of Refrigeration 24 2001 577 587 (Pubitemid 32640124)
    • (2001) International Journal of Refrigeration , vol.24 , Issue.6 , pp. 577-587
    • Dutta, A.K.1    Yanagisawa, T.2    Fukuta, M.3
  • 7
    • 77950850204 scopus 로고
    • (in Chinese) Science Press Beijing
    • Q.Y. Huang Ejector (in Chinese) 1977 Science Press Beijing pp. 1-132
    • (1977) Ejector , pp. 1-132
    • Huang, Q.Y.1
  • 8
    • 4644346686 scopus 로고    scopus 로고
    • (in Chinese) China Machine Press Beijing
    • L.S. Li Scroll Compressor (in Chinese) 1998 China Machine Press Beijing pp. 14-32
    • (1998) Scroll Compressor , pp. 14-32
    • Li, L.S.1
  • 9
    • 0037211453 scopus 로고    scopus 로고
    • Experimental investigation of air-source heat pump for cold regions
    • G.Y. Ma, Q.H. Chai, and Y. Jiang Experimental investigation of air-source heat pump for cold regions International Journal of Refrigeration 26 1 2003 12 18
    • (2003) International Journal of Refrigeration , vol.26 , Issue.1 , pp. 12-18
    • Ma, G.Y.1    Chai, Q.H.2    Jiang, Y.3
  • 12
    • 33845215651 scopus 로고    scopus 로고
    • Design of experiment bench and internal pressure measurement of scroll compressor with refrigerant injection
    • B.L. Wang, X.T. Li, W.X. Shi, and Q.S. Yan Design of experiment bench and internal pressure measurement of scroll compressor with refrigerant injection International Journal of Refrigeration 30 2007 179 186
    • (2007) International Journal of Refrigeration , vol.30 , pp. 179-186
    • Wang, B.L.1    Li, X.T.2    Shi, W.X.3    Yan, Q.S.4
  • 13
    • 0036462726 scopus 로고    scopus 로고
    • Experimental analysis and simplified modelling of a hermetic scroll refrigeration compressor
    • DOI 10.1016/S1359-4311(01)00083-7, PII S1359431101000837
    • E. Winandy, O.C. Saavedra, and J. Lebrun Experimental analysis and simplified modeling of a hermetic scroll refrigeration compressor Applied Thermal Engineering 22 2002 107 120 (Pubitemid 33039393)
    • (2002) Applied Thermal Engineering , vol.22 , Issue.2 , pp. 107-120
    • Winandy, E.1    Saavedra O, C.S.2    Lebrun, J.3
  • 14
    • 33745662411 scopus 로고    scopus 로고
    • Experiment study on heat pump system with scroll compressor flash tank
    • H.X. Zhao, S.G. Liu, Z.B. Liu, and G.Y. Ma Experiment study on heat pump system with scroll compressor flash tank Acta Energiae Solaris Sinica 27 5 2006 377 381
    • (2006) Acta Energiae Solaris Sinica , vol.27 , Issue.5 , pp. 377-381
    • Zhao, H.X.1    Liu, S.G.2    Liu, Z.B.3    Ma, G.Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.