메뉴 건너뛰기




Volumn 22, Issue 10, 2011, Pages

Quantitative electrical detection of immobilized protein using gold nanoparticles and gold enhancement on a biochip

Author keywords

gold nanoparticles; immunoassay; interdigitated electrode; microfluidics

Indexed keywords

BIOCHIPS; CHEMICAL DETECTION; CHEMICAL SENSORS; ELECTRODES; FIBER OPTIC SENSORS; GOLD; IMMUNOLOGY; MICROFLUIDICS; NANOPARTICLES; PROTEINS; TIN OXIDES;

EID: 80052751749     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/22/10/105802     Document Type: Article
Times cited : (19)

References (32)
  • 1
    • 0036646094 scopus 로고    scopus 로고
    • Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection
    • DOI 10.1021/ac015645b
    • Yakovleva J, Davidsson R, Lobanova A, Bengtsson M, Eremin S, Laurell T and Emneus J 2002 Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection Anal. Chem. 74 2994-3004 (Pubitemid 34759949)
    • (2002) Analytical Chemistry , vol.74 , Issue.13 , pp. 2994-3004
    • Yakovleva, J.1    Davidsson, R.2    Lobanova, A.3    Bengtsson, M.4    Eremin, S.5    Laurell, T.6    Emneus, J.7
  • 2
    • 33746801083 scopus 로고    scopus 로고
    • On-chip enzyme immunoassay of a cardiac marker using a microfluidic device combined with a portable surface plasmon resonance system
    • DOI 10.1021/ac060480y
    • Kurita R, Yokota Y, Sato Y, Mizutani F and Niwa O 2006 On-chip enzyme immunoassay of a cardiac marker using a microfluidic device combined with a portable surface plasmon resonance system Anal. Chem. 78 5525-31 (Pubitemid 44182373)
    • (2006) Analytical Chemistry , vol.78 , Issue.15 , pp. 5525-5531
    • Kurita, R.1    Yokota, Y.2    Sato, Y.3    Mizutani, F.4    Niwa, O.5
  • 7
    • 67650333626 scopus 로고    scopus 로고
    • Design and testing of a microfluidic biochip for cytokine enzyme-linked immunosorbent assay
    • He H, Yuan Y, Wang W, Chiou N R, Epstein A J and Lee L J 2009 Design and testing of a microfluidic biochip for cytokine enzyme-linked immunosorbent assay Biomicrofluidics 3 022401
    • (2009) Biomicrofluidics , vol.3 , Issue.2 , pp. 022401
    • He, H.1    Yuan, Y.2    Wang, W.3    Chiou, N.R.4    Epstein, A.J.5    Lee, L.J.6
  • 8
    • 18844373863 scopus 로고    scopus 로고
    • Magnetic bead-based chemiluminescent metal immunoassay with a colloidal gold label
    • DOI 10.1021/ac050163b
    • Fan A, Lau C and Lu J 2005 Magnetic bead-based chemiluminescent metal immunoassay with a colloidal gold label Anal. Chem. 77 3238-42 (Pubitemid 40695481)
    • (2005) Analytical Chemistry , vol.77 , Issue.10 , pp. 3238-3242
    • Fan, A.1    Lau, C.2    Lu, J.3
  • 9
    • 5644282799 scopus 로고    scopus 로고
    • Metal-enhanced fluorescence immunoassays using total internal reflection and silver island-coated surfaces
    • DOI 10.1016/j.ab.2004.08.034, PII S0003269704006979
    • Matveeva E, Gryczynski Z, Malicka J, Gryczynski I and Lakowicz J R 2004 Metal-enhanced fluorescence immunoassays using total internal reflection and silver island-coated surfaces Anal. Biochem. 334 303-311 (Pubitemid 39370966)
    • (2004) Analytical Biochemistry , vol.334 , Issue.2 , pp. 303-311
    • Matveeva, E.1    Gryczynski, Z.2    Malicka, J.3    Gryczynski, I.4    Lakowicz, J.R.5
  • 11
    • 57349200274 scopus 로고    scopus 로고
    • Development and evaluation of realistic microbioassays in freely suspended droplets on a chip
    • Rastogi V and Velev O D 2007 Development and evaluation of realistic microbioassays in freely suspended droplets on a chip Biomicrofluidics 1 014107
    • (2007) Biomicrofluidics , vol.1 , Issue.1 , pp. 014107
    • Rastogi, V.1    Velev, O.D.2
  • 12
    • 22144458002 scopus 로고    scopus 로고
    • Sensitivity enhancement of surface plasmon resonance biosensing of small molecules
    • DOI 10.1016/j.ab.2005.05.001, PII S0003269705003623
    • Mitchell J S, Wu Y, Cook C J and Main L 2005 Sensitivity enhancement of surface plasmon resonance biosensing of small molecules Anal. Biochem. 343 125-35 (Pubitemid 40978617)
    • (2005) Analytical Biochemistry , vol.343 , Issue.1 , pp. 125-135
    • Mitchell, J.S.1    Wu, Y.2    Cook, C.J.3    Main, L.4
  • 13
    • 0033230274 scopus 로고    scopus 로고
    • Immunoassay readout method using extrinsic Raman labels adsorbed on immunogold colloids
    • Ni J, Lipert R J, Dawson G B and Porter M D 1999 Immunoassay readout method using extrinsic Raman labels adsorbed on immunogold colloids Anal. Chem. 71 4903-8
    • (1999) Anal. Chem. , vol.71 , Issue.21 , pp. 4903-4908
    • Ni, J.1    Lipert, R.J.2    Dawson, G.B.3    Porter, M.D.4
  • 15
    • 0022893721 scopus 로고
    • Silver-enhanced colloidal gold probes as markers for scanning electron microscopy
    • Seopsi L, Larsson L I, Bastholm L and Nielsen M H 1986 Silver-enhanced colloidal gold probes as markers for scanning electron microscopy Histochem. Cell Biol. 86 35-41 (Pubitemid 17022928)
    • (1986) Histochemistry , vol.86 , Issue.1 , pp. 35-41
    • Scopsi, L.1    Larsson, L.I.2    Bastholm, L.3    Hartvig Nielsen, M.4
  • 16
    • 0034622970 scopus 로고    scopus 로고
    • Scanometric DNA array detection with nanoparticle probes
    • Taton T A, Mirkin C A and Letsinger R L 2000 Scanometric DNA array detection with nanoparticle probes Science 289 1757-60
    • (2000) Science , vol.289 , Issue.5485 , pp. 1757-1760
    • Taton, T.A.1    Mirkin, C.A.2    Letsinger, R.L.3
  • 18
    • 0037154825 scopus 로고    scopus 로고
    • Array-based electrical detection of DNA with nanoparticle probes
    • DOI 10.1126/science.1067003
    • Park S J, Taton T A and Mirkin C A 2002 Array-based electrical detection of DNA with nanoparticle probes Science 295 1503-6 (Pubitemid 34174000)
    • (2002) Science , vol.295 , Issue.5559 , pp. 1503-1506
    • Park, S.-J.1    Taton, T.A.2    Mirkin, C.A.3
  • 20
    • 58149134813 scopus 로고    scopus 로고
    • Electrical detection of oligonucleotide using an aggregate of gold nanoparticles as a conductive tag
    • Fang C, Fan Y, Kong J, Gao Z and Balasubramanian N 2008 Electrical detection of oligonucleotide using an aggregate of gold nanoparticles as a conductive tag Anal. Chem. 80 9387-94
    • (2008) Anal. Chem. , vol.80 , Issue.24 , pp. 9387-9394
    • Fang, C.1    Fan, Y.2    Kong, J.3    Gao, Z.4    Balasubramanian, N.5
  • 21
    • 54249145028 scopus 로고    scopus 로고
    • A label-free visual immunoassay on solid support with silver nanoparticles as plasmon resonance scattering indicator
    • Ling J, Li Y F and Huang C Z 2008 A label-free visual immunoassay on solid support with silver nanoparticles as plasmon resonance scattering indicator Anal. Biochem. 383 168-73
    • (2008) Anal. Biochem. , vol.383 , Issue.2 , pp. 168-173
    • Ling, J.1    Li, Y.F.2    Huang, C.Z.3
  • 22
    • 58249094557 scopus 로고    scopus 로고
    • An immunoassay using antibody-gold nanoparticle conjugate, silver enhancement and flat bed scanner
    • Yeh C H, Hung C Y, Chang T C, Lin H P and Lin Y C 2009 An immunoassay using antibody-gold nanoparticle conjugate, silver enhancement and flat bed scanner Microfluid. Nanofluid. 6 85-91
    • (2009) Microfluid. Nanofluid. , vol.6 , Issue.1 , pp. 85-91
    • Yeh, C.H.1    Hung, C.Y.2    Chang, T.C.3    Lin, H.P.4    Lin, Y.C.5
  • 23
    • 72149101596 scopus 로고    scopus 로고
    • Colorimetric immunoassay chip based on gold nanoparticles and gold enhancement
    • Lei K F and Butt Y K C 2010 Colorimetric immunoassay chip based on gold nanoparticles and gold enhancement Microfluid. Nanofluid. 8 131-7
    • (2010) Microfluid. Nanofluid. , vol.8 , Issue.1 , pp. 131-137
    • Lei, K.F.1    Butt, Y.K.C.2
  • 24
    • 0034669305 scopus 로고    scopus 로고
    • An electrochemical metalloimmunoassay based on a colloidal gold label
    • Dequaire M, Degrand C and Limoges B 2000 An electrochemical metalloimmunoassay based on a colloidal gold label Anal. Chem. 72 5521-8
    • (2000) Anal. Chem. , vol.72 , Issue.22 , pp. 5521-5528
    • Dequaire, M.1    Degrand, C.2    Limoges, B.3
  • 25
    • 12844262355 scopus 로고    scopus 로고
    • An electrochemical stripping metalloimmunoassay based on silver-enhanced gold nanoparticle label
    • DOI 10.1016/j.bios.2004.07.012, PII S0956566304003227
    • Chu X, Fu X, Chen K, Shen G L and Yu R Q 2005 An electrochemical stripping metalloimmunoassay based on silver-enhanced gold nanoparticle label Biosens. Bioelectron. 20 1805-12 (Pubitemid 40170150)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.9 , pp. 1805-1812
    • Chu, X.1    Fu, X.2    Chen, K.3    Shen, G.-L.4    Yu, R.-Q.5
  • 26
    • 33751427439 scopus 로고    scopus 로고
    • A chemiluminescent metalloimmunoassay based on silver deposition on colloidal gold labels
    • Li Z P, Liu C H, Fan Y S, Wang Y C and Duan X R 2006 A chemiluminescent metalloimmunoassay based on silver deposition on colloidal gold labels Anal. Biochem. 359 247-52
    • (2006) Anal. Biochem. , vol.359 , Issue.2 , pp. 247-252
    • Li, Z.P.1    Liu, C.H.2    Fan, Y.S.3    Wang, Y.C.4    Duan, X.R.5
  • 27
    • 0028295673 scopus 로고    scopus 로고
    • Covalent immobilization of protein monolayers for biosensor applications
    • Williams R A and Blanch H W 2004 Covalent immobilization of protein monolayers for biosensor applications Biosens. Bioelectron. 9 159-67
    • (2004) Biosens. Bioelectron. , vol.9 , Issue.2 , pp. 159-167
    • Williams, R.A.1    Blanch, H.W.2
  • 28
    • 0001553437 scopus 로고    scopus 로고
    • Oriented Immobilization of Proteins
    • Rao S V, Anderson K W and Bachas L G 1998 Oriented immobilization of proteins Mikrochim. Acta 128 127-43 (Pubitemid 128476578)
    • (1998) Mikrochimica Acta , vol.128 , Issue.3 , pp. 127-143
    • Rao, S.V.1    Anderson, K.W.2    Bachas, L.G.3
  • 29
    • 0025943379 scopus 로고
    • Gold enhancement of gold-labeled probes: Gold-intensified staining technique (GIST)
    • Morris R E, Ciraolo G M and Saelinger C B 1991 Gold enhancement of gold-labeled probes: gold-intensified staining technique (GIST) J. Histochem. Cytochem. 39 1585-91
    • (1991) J. Histochem. Cytochem. , vol.39 , Issue.11 , pp. 1585-1591
    • Morris, R.E.1    Ciraolo, G.M.2    Saelinger, C.B.3
  • 30
    • 0026738878 scopus 로고
    • Localization of immunoreactive tyrosine hydroxylase in the goldfish retina with pre-embedding immunolabeling with one-nanometer colloidal gold particles and gold toning
    • Marshak D W 1992 Localization of immunoreactive tyrosine hydroxylase in the goldfish retina with pre-embedding immunolabeling with one-nanometer colloidal gold particles and gold toning J. Histochem. Cytochem. 40 1465-70
    • (1992) J. Histochem. Cytochem. , vol.40 , Issue.10 , pp. 1465-1470
    • Marshak, D.W.1
  • 31
    • 0034524912 scopus 로고    scopus 로고
    • Signal enhancement at the electron microscopic level using nanogold and gold-based autometallography
    • Weipoltshammer K, Schofer C, Almeder M and Wachtler F 2000 Signal enhancement at the electron microscopic level using nanogold and gold-based autometallography Histochem. Cell Biol. 114 489-95 (Pubitemid 32039600)
    • (2000) Histochemistry and Cell Biology , vol.114 , Issue.6 , pp. 489-495
    • Weipoltshammer, K.1    Schofer, C.2    Almeder, M.3    Wachtler, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.