메뉴 건너뛰기




Volumn , Issue , 2011, Pages 71-76

Design a portable bio-sensing system for glucose measurement

Author keywords

bio sensors; carbon electrode; enzyme; Glucose electrochemical; potentiostat

Indexed keywords

AUTOMATIC TEST SYSTEM; BIODETECTION; BIOSENSING; CARBON-ELECTRODE; DAQ CARDS; ELECTRONIC SIGNALS; GLUCOSE BIOSENSOR; GLUCOSE CONCENTRATION; GLUCOSE DETECTION; GLUCOSE MEASUREMENTS; GLUCOSE TEST; LAB VIEW; MEASUREMENT RESULTS; OUTPUT RANGE; OXIDATION-REDUCTION REACTION; POTENTIOSTATS; PROCESSING PROPERTIES; READ-OUT CIRCUIT; READ-OUT DATA; VLSI DESIGN;

EID: 80052737882     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CISIS.2011.20     Document Type: Conference Paper
Times cited : (11)

References (15)
  • 1
    • 10244223555 scopus 로고
    • Electrode Systems for Continuous Monitoring in Cardiovascular Surgery
    • L. Clark and C. Lyons, "Electrode Systems for Continuous Monitoring in Cardiovascular Surgery," Ann. N. Y. Acad. Sci, vol. 102, 1962.
    • (1962) Ann. N. Y. Acad. Sci , vol.102
    • Clark, L.1    Lyons, C.2
  • 4
    • 0028845409 scopus 로고
    • Interface Analysis in Biosensor design
    • W. Gopel and P. Heiduschka, "Interface Analysis in Biosensor design,"Biosensors & bioelectronics, Vol. 10, pp. 853-8838, 1995.
    • (1995) Biosensors & Bioelectronics , vol.10 , pp. 853-8838
    • Gopel, W.1    Heiduschka, P.2
  • 6
    • 29944443113 scopus 로고    scopus 로고
    • Electrochemical Nonenzymatic Glucose sensors
    • Sejin park, Hankil Boo, and taek Dong Chung, "Electrochemical Nonenzymatic Glucose sensors," Analytica Chemica Acta, Vol. 556, pp. 46-57, 2006.
    • (2006) Analytica Chemica Acta , vol.556 , pp. 46-57
    • Park, S.1    Boo, H.2    Chung, T.D.3
  • 7
    • 44349148840 scopus 로고    scopus 로고
    • Current Development in Non-invasive Glucose Monitoring
    • Carlos Eduardo Ferrante do Amaral, Benhard Wolf, " Current Development in Non-invasive Glucose Monitoring," Medical Engineering & Physics, Vol. 30, pp. 541-549, 2008.
    • (2008) Medical Engineering & Physics , vol.30 , pp. 541-549
    • Do Amaral, C.E.F.1    Wolf, B.2
  • 8
    • 67651160770 scopus 로고    scopus 로고
    • Current-Mirror Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors
    • July
    • Mohammad Mahdi Ahmadi, Graham A. Jullien, "Current-Mirror Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors," IEEE Transactions on Circuits and Systems I, Volume 56, Issue 7, pp.1339-1348, July 2009.
    • (2009) IEEE Transactions on Circuits and Systems I , vol.56 , Issue.7 , pp. 1339-1348
    • Ahmadi, M.M.1    Jullien, G.A.2
  • 9
    • 67349205845 scopus 로고    scopus 로고
    • Polymeric Luminol on Pre-treated Screen-printed Electrodes for the Design of Performant Reagentless bio-Sensor
    • Audrey Sassolas, L. Blum, B.D. Leca-Bouvier, "Polymeric Luminol on Pre-treated Screen-printed Electrodes for the Design of Performant Reagentless bio-Sensor," Sensors and Actuators B: Chemical, Vol. 139, pp.214-221, 2009.
    • (2009) Sensors and Actuators B: Chemical , vol.139 , pp. 214-221
    • Sassolas, A.1    Blum, L.2    Leca-Bouvier, B.D.3
  • 11
    • 1642373669 scopus 로고    scopus 로고
    • CMOS Chip as Luminescent Sensor for Biochemical Reactions
    • June
    • U.Lu, C.-P.Hu, Y.C. Shih, Y.-S.Yang, C.-Y. Wu, and et al, "CMOS Chip as Luminescent Sensor for Biochemical Reactions," IEEE Journal of Sensor, vol. 3, no. 3, pp. 310-316, June 2003.
    • (2003) IEEE Journal of Sensor , vol.3 , Issue.3 , pp. 310-316
    • Lu, U.1    Hu, C.-P.2    Shih, Y.C.3    Yang, Y.-S.4    Wu, C.-Y.5
  • 14
    • 56449089458 scopus 로고    scopus 로고
    • Model the Effect of Environmental Solution pH on the Mechanical Characteristics of Glucose-sensitive Hygrogels
    • Rongmo Luo, Hua Li, and Khin Yong Lam, " Model the Effect of Environmental Solution pH on the Mechanical Characteristics of Glucose-sensitive Hygrogels," Biomaterials, Vol. 30, pp.690-700, 2009.
    • (2009) Biomaterials , vol.30 , pp. 690-700
    • Luo, R.1    Li, H.2    Lam, K.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.