메뉴 건너뛰기




Volumn 50, Issue 12, 2011, Pages 2514-2521

Numerical investigations of solar cell temperature for photovoltaic concentrator system with and without passive cooling arrangements

Author keywords

Cell temperature correlation; Cooling fins; PV concentrator; Solar cell temperature

Indexed keywords

2-D MODEL; A-THERMAL; CELL TEMPERATURE; CONCENTRATING PV; CONCENTRATION RATIO; CONCENTRATOR SYSTEMS; COOLING FINS; INFLUENCING PARAMETERS; NUMERICAL INVESTIGATIONS; NUMERICAL STUDIES; PASSIVE COOLING; PHOTOVOLTAIC CONCENTRATOR SYSTEM; PV CONCENTRATOR; SOLAR CELL TEMPERATURE; SOLAR RADIATION INTENSITY; THERMAL MODEL; UNIFIED MODEL;

EID: 80052732700     PISSN: 12900729     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijthermalsci.2011.06.014     Document Type: Article
Times cited : (101)

References (24)
  • 2
    • 1842534278 scopus 로고    scopus 로고
    • Thermal regulation of building-integrated photovoltaics using phase change materials
    • DOI 10.1016/j.ijheatmasstransfer.2003.11.015, PII S0017931003006380
    • M.J. Huang, P.C. Eames, and B. Norton Thermal regulations of building-integrated photovoltaics using phase change materials Int. J. Heat Mass Transfer 47 2004 2715 2733 (Pubitemid 38454056)
    • (2004) International Journal of Heat and Mass Transfer , vol.47 , Issue.12-13 , pp. 2715-2733
    • Huang, M.J.1    Eames, P.C.2    Norton, B.3
  • 3
    • 0032058188 scopus 로고    scopus 로고
    • Effect of ambient temperature on the demanded energy of solar cells at different inclinations
    • PII S0960148198000615
    • A.M. Al-Sabounchi Effect of ambient temperature on the demanded energy of solar cells at different inclinations Renew. Energy 14 1-4 1998 149 155 (Pubitemid 128369234)
    • (1998) Renewable Energy , vol.14 , Issue.1-4 , pp. 149-155
    • Al- Sabounchi, A.M.1
  • 8
    • 0035796497 scopus 로고    scopus 로고
    • The experimental validation of a comprehensive unified model for optics and heat transfer in line-axis solar energy systems
    • DOI 10.1016/S0038-092X(01)00027-5, PII S0038092X01000275
    • P.C. Eames, M. Smyth, and B. Norton The experimental validation of a comprehensive unified model for optics and heat transfer in line-axis solar energy systems Solar Energy 71 2 2001 121 133 (Pubitemid 32632865)
    • (2001) Solar Energy , vol.71 , Issue.2 , pp. 121-133
    • Eames, P.C.1    Smyth, M.2    Norton, B.3
  • 9
    • 33846063756 scopus 로고    scopus 로고
    • Using air flow to alleviate temperature elevation in solar cells within asymmetric compound parabolic concentrators
    • DOI 10.1016/j.solener.2006.04.003, PII S0038092X0600106X
    • T.K. Mallick, P.C. Eames, and B. Norton Using air flow to alleviate temperature elevation in solar cells within asymmetric compound parabolic concentrators Solar Energy 81 2007 173 184 (Pubitemid 46070187)
    • (2007) Solar Energy , vol.81 , Issue.2 , pp. 173-184
    • Mallick, T.K.1    Eames, P.C.2    Norton, B.3
  • 12
    • 33847020724 scopus 로고    scopus 로고
    • Design and fabrication of low concentrating second generation PRIDE concentrator
    • DOI 10.1016/j.solmat.2006.11.016, PII S0927024806004569
    • T.K. Mallick, and P.C. Eames Design and fabrication of low concentrating second generation PRIDE concentrator Solar Energy Mater. Solar Cells 91 2007 597 608 (Pubitemid 46274201)
    • (2007) Solar Energy Materials and Solar Cells , vol.91 , Issue.7 , pp. 597-608
    • Mallick, T.K.1    Eames, P.C.2
  • 13
    • 0000754350 scopus 로고    scopus 로고
    • Linear dielectric non-imaging concentrating covers for PV integrated building facades
    • A. Zacharopoulos, P.C. Eames, D. Mclarnon, and B. Norton Linear dielectric non-imaging concentrating covers for PV integrated building facades Solar Energy 68 5 2000 439 452
    • (2000) Solar Energy , vol.68 , Issue.5 , pp. 439-452
    • Zacharopoulos, A.1    Eames, P.C.2    McLarnon, D.3    Norton, B.4
  • 15
    • 13844316975 scopus 로고    scopus 로고
    • Cooling of photovoltaic cells under concentrated illumination: A critical review
    • DOI 10.1016/j.solmat.2004.09.003, PII S0927024804003071
    • A. Royne, C.J. Dey, and D.R. Mills Cooling of photovoltaic cells under concentrated illumination: a critical review Solar Energy Mater. Solar Cells 86 2005 451 483 (Pubitemid 40259542)
    • (2005) Solar Energy Materials and Solar Cells , vol.86 , Issue.4 , pp. 451-483
    • Royne, A.1    Dey, C.J.2    Mills, D.R.3
  • 16
    • 19944389571 scopus 로고    scopus 로고
    • Design and simulation of a low concentrating photovoltaic/thermal system
    • J.I. Rosell, X. Vallverdu, M.A. Lechon, and M. Ibanez Design and simulation of a low concentrating photovoltaic/thermal system Energy Convers. Manage. 46 2005 3034 3046
    • (2005) Energy Convers. Manage. , vol.46 , pp. 3034-3046
    • Rosell, J.I.1    Vallverdu, X.2    Lechon, M.A.3    Ibanez, M.4
  • 17
    • 30744467416 scopus 로고    scopus 로고
    • Performance of concentrator solar cells with passive cooling
    • DOI 10.1088/0268-1242/21/2/007, PII S0268124206042556
    • K. Cheknane, B. Benyoucef, and A. Chaker Performance of concentrator solar cells with passive cooling Semiconduct. Sci. Technol. 21 2006 144 147 (Pubitemid 43099586)
    • (2006) Semiconductor Science and Technology , vol.21 , Issue.2 , pp. 144-147
    • Cheknane, A.1    Benyoucef, B.2    Chaker, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.