메뉴 건너뛰기




Volumn 29, Issue 7, 2011, Pages 457-465

Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography

Author keywords

Bolus tracking; Cardiac; Computed tomography; Contrast injection protocol; Test bolus

Indexed keywords

IOHEXOL;

EID: 80052714212     PISSN: 18671071     EISSN: 1867108X     Source Type: Journal    
DOI: 10.1007/s11604-011-0579-5     Document Type: Article
Times cited : (25)

References (23)
  • 1
    • 33646102670 scopus 로고    scopus 로고
    • Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: Comparison with conventional invasive angiography
    • 16636491 10.1253/circj.70.564
    • M. Ehara J.F. Surmely M. Kawai O. Katoh T. Matsubara M. Terashima, et al. 2006 Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography Circ J 70 564 571 16636491 10.1253/circj.70.564
    • (2006) Circ J , vol.70 , pp. 564-571
    • Ehara, M.1    Surmely, J.F.2    Kawai, M.3    Katoh, O.4    Matsubara, T.5    Terashima, M.6
  • 3
    • 33747146464 scopus 로고    scopus 로고
    • Coronary CT angiography with 64-MDCT: Assessment of vessel visibility
    • DOI 10.2214/AJR.05.0908
    • H.K. Pannu J.E. Jacobs S. Lai E.K. Fishman 2006 Coronary CT angiography with 64-MDCT: assessment of vessel visibility AJR Am J Roentgenol 187 119 126 16794165 10.2214/AJR.05.0908 (Pubitemid 46100156)
    • (2006) American Journal of Roentgenology , vol.187 , Issue.1 , pp. 119-126
    • Pannu, H.K.1    Jacobs, J.E.2    Lai, S.3    Fishman, E.K.4
  • 4
    • 33750106461 scopus 로고    scopus 로고
    • Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography
    • 16985117 10.2214/AJR.05.1406
    • F. Cademartiri N.R. Mollet P.A. Lemos F. Saia M. Midiri P.J. de Feyter, et al. 2006 Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography AJR Am J Roentgenol 187 W430 W433 16985117 10.2214/AJR.05.1406
    • (2006) AJR Am J Roentgenol , vol.187
    • Cademartiri, F.1    Mollet, N.R.2    Lemos, P.A.3    Saia, F.4    Midiri, M.5    De Feyter, P.J.6
  • 6
    • 50949087072 scopus 로고    scopus 로고
    • Contrast injection protocols for coronary computed tomography angiography using a 64-detector scanner: Comparison between patient weight-adjusted- and fixed iodinedose protocols
    • 18580334 10.1097/RLI.0b013e3181727505
    • T. Nakaura K. Awai Y. Yauaga Y. Nakayama S. Oda M. Hatemura, et al. 2008 Contrast injection protocols for coronary computed tomography angiography using a 64-detector scanner: comparison between patient weight-adjusted- and fixed iodinedose protocols Invest Radiol 43 512 519 18580334 10.1097/RLI. 0b013e3181727505
    • (2008) Invest Radiol , vol.43 , pp. 512-519
    • Nakaura, T.1    Awai, K.2    Yauaga, Y.3    Nakayama, Y.4    Oda, S.5    Hatemura, M.6
  • 7
    • 39749180841 scopus 로고    scopus 로고
    • Contrast enhancement in cardiovascular MDCT: Effect of body weight, height, body surface area, body mass index, and obesity
    • DOI 10.2214/AJR.07.2765
    • K.T. Bae B.A. Seeck C.F. Hildebolt C. Tao F. Zhu M. Kanematsu, et al. 2008 Contrast enhancement in cardiovascular MDCT: effect of body weight, height, body surface area, body mass index, and obesity AJR Am J Roentgenol 190 777 784 18287452 10.2214/AJR.07.2765 (Pubitemid 351304525)
    • (2008) American Journal of Roentgenology , vol.190 , Issue.3 , pp. 777-784
    • Bae, K.T.1    Seeck, B.A.2    Hildebolt, C.F.3    Tao, C.4    Zhu, F.5    Kanematsu, M.6    Woodard, P.K.7
  • 8
    • 34147131781 scopus 로고    scopus 로고
    • Coronary angiography by 64-detector row computed tomography using low dose of contrast material with saline chaser: Influence of total injection volume on vessel attenuation
    • DOI 10.1097/01.rct.0000236422.35761.a1, PII 0000472820070300000020
    • M. Yamamuro E. Tadamura S. Kanao Y.W. Wu K. Tambara M. Komeda, et al. 2007 Coronary angiography by 64-detector row computed tomography using low dose of contrast material with saline chaser: influence of total injection volume on vessel attenuation J Comput Assist Tomogr 31 272 280 17414766 10.1097/01.rct.0000236422.35761.a1 (Pubitemid 46573368)
    • (2007) Journal of Computer Assisted Tomography , vol.31 , Issue.2 , pp. 272-280
    • Yamamuro, M.1    Tadamura, E.2    Kanao, S.3    Wu, Y.-W.4    Tambara, K.5    Komeda, M.6    Toma, M.7    Kimura, T.8    Kita, T.9    Togashi, K.10
  • 9
    • 0034885355 scopus 로고    scopus 로고
    • Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT
    • DOI 10.1007/s003300000816
    • J.J. Sandstede A. Tschammler M. Beer C. Vogelsang G. Wittenberg D. Hahn 2001 Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT Eur Radiol 11 1396 1400 11519548 10.1007/s003300000816 1:STN:280:DC%2BD3Mvns1aitQ%3D%3D (Pubitemid 32755624)
    • (2001) European Radiology , vol.11 , Issue.8 , pp. 1396-1400
    • Sandstede, J.J.W.1    Tschammler, A.2    Beer, M.3    Vogelsang, C.4    Wittenberg, G.5    Hahn, D.6
  • 10
    • 16544371386 scopus 로고    scopus 로고
    • Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique
    • 15516601 10.1148/radiol.2333030668
    • F. Cademartiri K. Nieman A. van der Lugt R.H. Raaijmakers N. Mollet P.M. Pattynama, et al. 2004 Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique Radiology 233 817 823 15516601 10.1148/radiol. 2333030668
    • (2004) Radiology , vol.233 , pp. 817-823
    • Cademartiri, F.1    Nieman, K.2    Van Der Lugt, A.3    Raaijmakers, R.H.4    Mollet, N.5    Pattynama, P.M.6
  • 11
    • 18844430618 scopus 로고    scopus 로고
    • Incidence of contrast nephropathy from cerebral CT angiography and CT perfusion imaging
    • DOI 10.1212/01.WNL.0000161845.69114.62
    • S.A. Josephson W.P. Dillon W.S. Smith 2005 Incidence of contrast nephropathy from cerebral CT angiography and CT perfusion imaging Neurology 64 1805 1806 15911820 10.1212/01.WNL.0000161845.69114.62 (Pubitemid 40695827)
    • (2005) Neurology , vol.64 , Issue.10 , pp. 1805-1806
    • Josephson, S.A.1    Dillon, W.P.2    Smith, W.S.3
  • 13
    • 22544474645 scopus 로고    scopus 로고
    • Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation
    • DOI 10.1148/radiol.2362040468
    • F. Cademartiri N.R. Mollet A. van der Lugt E.P. McFadden T. Stijnen P.J. de Feyter, et al. 2005 Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation Radiology 236 661 665 16040923 10.1148/radiol.2362040468 (Pubitemid 41023456)
    • (2005) Radiology , vol.236 , Issue.2 , pp. 661-665
    • Cademartin, F.1    Mollet, N.R.2    Van Der Lugt, A.3    McFadden, E.P.4    Stijnen, T.5    De Feyter, P.J.6    Krestin, G.P.7
  • 14
    • 46849122235 scopus 로고    scopus 로고
    • 64-MDCT coronary angiography: Phantom study of effects of vascular attenuation on detection of coronary stenosis
    • DOI 10.2214/AJR.07.2653
    • X. Fei X. Du Q. Yang Y. Shen P. Li J. Liao, et al. 2008 64-MDCT coronary angiography: phantom study of effects of vascular attenuation on detection of coronary stenosis AJR Am J Roentgenol 191 43 49 18562723 10.2214/AJR.07.2653 (Pubitemid 351955181)
    • (2008) American Journal of Roentgenology , vol.191 , Issue.1 , pp. 43-49
    • Fei, X.1    Du, X.2    Yang, Q.3    Shen, Y.4    Li, P.5    Liao, J.6    Li, K.7
  • 15
    • 0038626429 scopus 로고    scopus 로고
    • Peak contrast enhancement in CT and MR angiography: When does it occur and why? Pharmacokinetic study in a porcine model
    • DOI 10.1148/radiol.2273020102
    • K.T. Bae 2003 Peak contrast enhancement in CT and MR angiography: when does it occur and why? Pharmacokinetic study in a porcine model Radiology 227 809 816 12702823 10.1148/radiol.2273020102 (Pubitemid 36583041)
    • (2003) Radiology , vol.227 , Issue.3 , pp. 809-816
    • Bae, K.T.1
  • 17
    • 0031813548 scopus 로고    scopus 로고
    • Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model
    • 9609887 1:STN:280:DyaK1c3nt1yjtQ%3D%3D
    • K.T. Bae J.P. Heiken J.A. Brink 1998 Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model Radiology 207 657 662 9609887 1:STN:280:DyaK1c3nt1yjtQ%3D%3D
    • (1998) Radiology , vol.207 , pp. 657-662
    • Bae, K.T.1    Heiken, J.P.2    Brink, J.A.3
  • 18
    • 0026547052 scopus 로고
    • Posttraumatic shock in children: CT findings associated with hemodynamic instability
    • 1535886 1:STN:280:DyaK387lvFeltw%3D%3D
    • C.J. Sivit G.A. Taylor D.I. Bulas D.C. Kushner B.M. Potter M.R. Eichelberger 1992 Posttraumatic shock in children: CT findings associated with hemodynamic instability Radiology 182 723 726 1535886 1:STN:280: DyaK387lvFeltw%3D%3D
    • (1992) Radiology , vol.182 , pp. 723-726
    • Sivit, C.J.1    Taylor, G.A.2    Bulas, D.I.3    Kushner, D.C.4    Potter, B.M.5    Eichelberger, M.R.6
  • 19
    • 0033969237 scopus 로고    scopus 로고
    • Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography
    • D. Fleischmann G.D. Rubin A.A. Bankier K. Hittmair 2000 Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography Radiology 214 363 371 10671582 1:STN:280: DC%2BD3c7jvVKmsg%3D%3D (Pubitemid 30077690)
    • (2000) Radiology , vol.214 , Issue.2 , pp. 363-371
    • Fleischmann, D.1    Rubin, G.D.2    Bankier, A.A.3    Hittmair, K.4
  • 20
    • 2442642826 scopus 로고    scopus 로고
    • Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method
    • DOI 10.1148/radiol.2313030497
    • K.T. Bae H.Q. Tran J.P. Heiken 2004 Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method Radiology 231 732 736 15163812 10.1148/radiol.2313030497 (Pubitemid 38668090)
    • (2004) Radiology , vol.231 , Issue.3 , pp. 732-736
    • Bae, K.T.1    Tran, H.Q.2    Heiken, J.P.3
  • 22
    • 34250743798 scopus 로고    scopus 로고
    • CTA contrast enhancement of the aorta and pulmonary artery: The effect of saline chase injected at two different rates in a canine experimental model
    • DOI 10.1097/RLI.0b013e318032a9fe, PII 0000442420070700000002
    • C.H. Lee J.M. Goo K.T. Bae H.J. Lee K.G. Kim E.J. Chun, et al. 2007 CTA contrast enhancement of the aorta and pulmonary artery: the effect of saline chase injected at two different rates in a canine experimental model Invest Radiol 42 486 490 17568270 10.1097/RLI.0b013e318032a9fe (Pubitemid 46955242)
    • (2007) Investigative Radiology , vol.42 , Issue.7 , pp. 486-490
    • Lee, C.H.1    Goo, J.M.2    Bae, K.T.3    Lee, H.J.4    Kim, K.G.5    Chun, E.J.6    Park, C.M.7    Im, J.-G.8
  • 23
    • 0037366639 scopus 로고    scopus 로고
    • Use of high concentration contrast media: Principles and rationale - Vascular district
    • DOI 10.1016/S0720-048X(02)00365-0
    • D. Fleischmann 2003 Use of high concentration contrast media: principles and rationale-vascular district Eur J Radiol 45 suppl1 S88 S93 12598032 10.1016/S0720-048X(02)00365-0 (Pubitemid 36206506)
    • (2003) European Journal of Radiology , vol.45 , Issue.SUPPL. 1
    • Fleischmann, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.