메뉴 건너뛰기




Volumn 28, Issue 8, 2011, Pages 597-599

The influence of head and neck position on ventilation with the i-gel airway in paralysed, anaesthetised patients

Author keywords

Head and neck position; I gel airway; Ventilation

Indexed keywords

ADULT; AGED; AIRWAY PRESSURE; ARTICLE; CAPNOGRAPHY; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HEAD MOVEMENT; HEAD POSITION; HUMAN; HYPOTHESIS; LUNG VENTILATION; MALE; NECK POSITION; PARALYSIS; PATIENT POSITIONING; PRESSURE MEASUREMENT; SCORING SYSTEM; SURGICAL PATIENT;

EID: 80052711399     PISSN: 02650215     EISSN: 13652346     Source Type: Journal    
DOI: 10.1097/EJA.0b013e32834698f4     Document Type: Article
Times cited : (30)

References (9)
  • 2
    • 0032957712 scopus 로고    scopus 로고
    • The influence of head and neck position on oropharyngeal leak pressure and cuff position with the flexible and the standard laryngeal mask airway
    • Keller C, Brimacombe J. The influence of head and neck position on oropharyngeal leak pressure and cuff position with the flexible and the standard laryngeal mask airway. Anesth Analg 1999; 88:913-916. (Pubitemid 29168870)
    • (1999) Anesthesia and Analgesia , vol.88 , Issue.4 , pp. 913-916
    • Keller, C.1    Brimacombe, J.2
  • 3
    • 0035186143 scopus 로고    scopus 로고
    • Influence of head and neck position on cuff position and oropharyngeal sealing pressure with the laryngeal mask airway in children
    • DOI 10.1093/bja/86.1.122
    • Okuda K, Inagawa G, Miwa T, Hiroki K. Influence of head and neck position on cuff position and oropharyngeal sealing pressure with the laryngeal mask airway in children. Br J Anaesth 2001; 86:122-124. (Pubitemid 32014131)
    • (2001) British Journal of Anaesthesia , vol.86 , Issue.1 , pp. 122-124
    • Okuda, K.1    Inagawa, G.2    Miwa, T.3    Hiroki, K.4
  • 4
    • 58749107356 scopus 로고    scopus 로고
    • The influence of head and neck position on the oropharyngeal leak pressure and cuff position of three supraglottic airway devices
    • Park SH, Han SH, Do SH, et al. The influence of head and neck position on the oropharyngeal leak pressure and cuff position of three supraglottic airway devices. Anesth Analg 2009; 108:112-117.
    • (2009) Anesth Analg , vol.108 , pp. 112-117
    • Park, S.H.1    Han, S.H.2    Do, S.H.3
  • 5
    • 58849114522 scopus 로고    scopus 로고
    • Flexion compromises ventilation with the laryngeal tube suction II in children
    • Kim JT, Na HS, Bae JY, et al. Flexion compromises ventilation with the laryngeal tube suction II in children. Paediatr Anaesth 2009; 19:153-158.
    • (2009) Paediatr Anaesth , vol.19 , pp. 153-158
    • Kim, J.T.1    Na, H.S.2    Bae, J.Y.3
  • 6
    • 41349109832 scopus 로고    scopus 로고
    • A new single use supraglottic airway device with a noninflatable cuff and an esophageal vent: An observational study of the i-gel
    • DOI 10.1213/ane.0b013e318164f062, PII 0000053920080400000017
    • Richez B, Saltel L, Banchereau F, et al. A new single use supraglottic airway device with a noninflatable cuff and an esophageal vent: an observational study of the i-gel. Anesth Analg 2008; 106:1137-1139. (Pubitemid 351450538)
    • (2008) Anesthesia and Analgesia , vol.106 , Issue.4 , pp. 1137-1139
    • Richez, B.1    Saltel, L.2    Banchereau, F.3    Torrielli, R.4    Cros, A.M.5
  • 7
    • 71749104416 scopus 로고    scopus 로고
    • Randomized crossover comparison between the i-gel and the LMA-unique in anaesthetized, paralysed adults
    • Uppal V, Gangaiah S, Fletcher G, Kinsella J. Randomized crossover comparison between the i-gel and the LMA-Unique in anaesthetized, paralysed adults. Br J Anaesth 2009; 103:882-885.
    • (2009) Br J Anaesth , vol.103 , pp. 882-885
    • Uppal, V.1    Gangaiah, S.2    Fletcher, G.3    Kinsella, J.4
  • 8
    • 0027528467 scopus 로고
    • A proposed fiber-optic scoring system to standardize the assessment of laryngeal mask airway position [10]
    • Brimacombe J, Berry A. A proposed fiber-optic scoring system to standardize the assessment of laryngeal mask airway position. Anesth Analg 1993; 76:457. (Pubitemid 23085774)
    • (1993) Anesthesia and Analgesia , vol.76 , Issue.2 , pp. 457
    • Brimacombe, J.1    Berry, A.2
  • 9
    • 38449101530 scopus 로고    scopus 로고
    • Alternative method for predicting optimal insertion depth of the laryngeal tube in children
    • DOI 10.1093/bja/aem241
    • Kim JT, Jeon SY, Kim CS, et al. Alternative method for predicting optimal insertion depth of the laryngeal tube in children. Br J Anaesth 2007; 99:704-707. (Pubitemid 351773211)
    • (2007) British Journal of Anaesthesia , vol.99 , Issue.5 , pp. 704-707
    • Kim, J.T.1    Jeon, S.Y.2    Kim, C.S.3    Kim, S.D.4    Kim, H.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.