메뉴 건너뛰기




Volumn 30, Issue 10 SUPPL. 1, 2011, Pages

Chandelier illumination for use during descemet stripping automated endothelial keratoplasty in patients with advanced bullous keratopathy

Author keywords

bullous keratopathy; chandelier illumination; Descemet stripping automated endothelial keratoplasty; infusion cannula

Indexed keywords

ANTERIOR EYE CHAMBER; CANNULA; CATARACT; CILIARY DISK; CONFERENCE PAPER; CORNEA; DESCEMET STRIPPING ENDOTHELIAL KERATOPLASTY; HUMAN; ILLUMINATION; IRIDOCORNEAL ENDOTHELIAL SYNDROME; KERATOPATHY; LENS IMPLANT; PHACOEMULSIFICATION; PRIORITY JOURNAL; VISIBILITY;

EID: 80052701651     PISSN: 02773740     EISSN: 15364798     Source Type: Journal    
DOI: 10.1097/ICO.0b013e3182281538     Document Type: Conference Paper
Times cited : (9)

References (16)
  • 1
    • 22644443452 scopus 로고    scopus 로고
    • Descemet's stripping with endothelial keratoplasty in 50 eyes: A refractive neutral corneal transplant
    • Price FW Jr, Price MO. Descemet's stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant. J Refract Surg. 2005;21: 339-345. (Pubitemid 41026058)
    • (2005) Journal of Refractive Surgery , vol.21 , Issue.4 , pp. 339-345
    • Price Jr., F.W.1    Price, M.O.2
  • 2
    • 33646036099 scopus 로고    scopus 로고
    • Descemet's stripping with endothelial keratoplasty in 200 eyes: Early challenges and techniques to enhance donor adherence
    • Price FW Jr, Price MO. Descemet's stripping with endothelial keratoplasty in 200 eyes: early challenges and techniques to enhance donor adherence. J Cataract Refract Surg. 2006;32:411-418.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 411-418
    • Price Jr., F.W.1    Price, M.O.2
  • 3
    • 33751110218 scopus 로고    scopus 로고
    • Descemet-stripping automated endothelial keratoplasty
    • DOI 10.1097/01.ico.0000214224.90743.01, PII 0000322620060900000005
    • Gorovoy MS. Descemet-stripping automated endothelial keratoplasty. Cornea. 2006;25:886-889. (Pubitemid 44763845)
    • (2006) Cornea , vol.25 , Issue.8 , pp. 886-889
    • Gorovoy, M.S.1
  • 4
    • 34147112719 scopus 로고    scopus 로고
    • Experience and 12-month results of Descemet-stripping endothelial keratoplasty (DSEK) with a small-incision technique
    • DOI 10.1097/ICO.0b013e31802cd8c2, PII 0000322620070400000008
    • Mearza AA, Qureshi MA, Rostron CK. Experience and 12-month results of Descemet-stripping endothelial keratoplasty (DSEK) with a smallincision technique. Cornea. 2007;26:279-283. (Pubitemid 46568826)
    • (2007) Cornea , vol.26 , Issue.3 , pp. 279-283
    • Mearza, A.A.1    Qureshi, M.A.2    Rostron, C.K.3
  • 5
    • 33846534105 scopus 로고    scopus 로고
    • Early results of small-incision Descemet's stripping and automated endothelial keratoplasty
    • Koenig SB, Covert DJ. Early results of small-incision Descemet's stripping and automated endothelial keratoplasty. Ophthalmology. 2007; 114:221-226.
    • (2007) Ophthalmology , vol.114 , pp. 221-226
    • Koenig, S.B.1    Covert, D.J.2
  • 6
    • 43849110911 scopus 로고    scopus 로고
    • Descemet-stripping automated endothelial keratoplasty: Six-month results in a prospective study of 100 eyes
    • Chen ES, Terry MA, Shamie N, et al. Descemet-stripping automated endothelial keratoplasty: six-month results in a prospective study of 100 eyes. Cornea. 2008;27:514-520.
    • (2008) Cornea , vol.27 , pp. 514-520
    • Chen, E.S.1    Terry, M.A.2    Shamie, N.3
  • 8
    • 51649106309 scopus 로고    scopus 로고
    • Descemet stripping with automated endothelial keratoplasty for bullous keratopathies secondary to argon laser iridotomy-preliminary results and usefulness of double-glide donor insertion technique
    • Kobayashi A, Yokogawa H, Sugiyama K. Descemet stripping with automated endothelial keratoplasty for bullous keratopathies secondary to argon laser iridotomy-preliminary results and usefulness of double-glide donor insertion technique. Cornea. 2008;27(suppl 1):S62-S69.
    • (2008) Cornea , vol.27 , Issue.SUPPL. 1
    • Kobayashi, A.1    Yokogawa, H.2    Sugiyama, K.3
  • 9
    • 43649105567 scopus 로고    scopus 로고
    • Chandelier illumination to complete Descemet stripping through severe hazy cornea during Descemet-stripping automated endothelial keratoplasty
    • DOI 10.1016/j.jcrs.2008.02.032, PII S0886335008003180
    • Inoue T, Oshima Y, Shima C, et al. Chandelier illumination to complete Descemet stripping through severe hazy cornea during Descemetstripping automated endothelial keratoplasty. J Cataract Refract Surg. 2008;34:892-896. (Pubitemid 351685650)
    • (2008) Journal of Cataract and Refractive Surgery , vol.34 , Issue.6 , pp. 892-896
    • Inoue, T.1    Oshima, Y.2    Shima, C.3    Hori, Y.4    Maeda, N.5    Tano, Y.6
  • 10
    • 77955175463 scopus 로고    scopus 로고
    • A chandelier-illuminated anterior chamber maintainer for use during Descemet stripping automated endothelial keratoplasty in patients with advanced bullous keratopathy
    • Inoue T, Oshima Y, Hori Y, et al. A chandelier-illuminated anterior chamber maintainer for use during Descemet stripping automated endothelial keratoplasty in patients with advanced bullous keratopathy. Cornea. 2010;29:917-920.
    • (2010) Cornea , vol.29 , pp. 917-920
    • Inoue, T.1    Oshima, Y.2    Hori, Y.3
  • 11
    • 33845485896 scopus 로고    scopus 로고
    • Self-retaining 27-gauge transconjunctival chandelier endoillumination for panoramic viewing during vitreous surgery
    • Oshima Y, Awh CC, Tano Y. Self-retaining 27-gauge transconjunctival chandelier endoillumination for panoramic viewing during vitreous surgery. Am J Ophthalmol. 2007;143:166-167.
    • (2007) Am J Ophthalmol , vol.143 , pp. 166-167
    • Oshima, Y.1    Awh, C.C.2    Tano, Y.3
  • 12
    • 36349019647 scopus 로고    scopus 로고
    • Chandelier retroillumination-assisted torsional oscillation for cataract surgery in patients with severe corneal opacity
    • DOI 10.1016/j.jcrs.2007.07.055, PII S0886335007016744
    • Oshima Y, Shima C, Maeda N, et al. Chandelier retroillumination-assisted torsional oscillation for cataract surgery in patients with severe corneal opacity. J Cataract Refract Surg. 2007;33:2018-2022. (Pubitemid 350161285)
    • (2007) Journal of Cataract and Refractive Surgery , vol.33 , Issue.12 , pp. 2018-2022
    • Oshima, Y.1    Shima, C.2    Maeda, N.3    Tano, Y.4
  • 13
    • 34347212143 scopus 로고    scopus 로고
    • New triple procedure: Descemet's stripping and automated endothelial keratoplasty combined with phacoemulsification and intraocular lens implantation
    • Covert DJ, Koenig SB. New triple procedure: Descemet's stripping and automated endothelial keratoplasty combined with phacoemulsification and intraocular lens implantation. Ophthalmology. 2007;114:1272-1277.
    • (2007) Ophthalmology , vol.114 , pp. 1272-1277
    • Covert, D.J.1    Koenig, S.B.2
  • 14
    • 33751117195 scopus 로고    scopus 로고
    • Endothelial keratoplasty to restore clarity to a failed penetrating graft
    • DOI 10.1097/01.ico.0000227888.03877.22, PII 0000322620060900000007
    • Price FW Jr, Price MO. Endothelial keratoplasty to restore clarity to a failed penetrating graft. Cornea. 2006;25:895-899. (Pubitemid 44763847)
    • (2006) Cornea , vol.25 , Issue.8 , pp. 895-899
    • Price Jr., F.W.1    Price, M.O.2
  • 15
    • 34250665404 scopus 로고    scopus 로고
    • Diagnosis of residual Descemet's membrane after Descemet's stripping endothelial keratoplasty with anterior segment optical coherence tomography
    • DOI 10.1016/j.jcrs.2007.03.029, PII S0886335007005846
    • Kymionis GD, Suh LH, Dubovy SR, et al. Diagnosis of residual Descemet's membrane after Descemet's stripping endothelial keratoplasty with anterior segment optical coherence tomography. J Cataract Refract Surg. 2007;33:1322-1324. (Pubitemid 46936130)
    • (2007) Journal of Cataract and Refractive Surgery , vol.33 , Issue.7 , pp. 1322-1324
    • Kymionis, G.D.1    Suh, L.H.2    Dubovy, S.R.3    Yoo, S.H.4
  • 16
    • 63149182028 scopus 로고    scopus 로고
    • Histopathologic examination of failed grafts in Descemet's stripping with automated endothelial keratoplasty
    • Suh LH, Dawson DG, Mutapcic L, et al. Histopathologic examination of failed grafts in Descemet's stripping with automated endothelial keratoplasty. Ophthalmology. 2009;116:603-608.
    • (2009) Ophthalmology , vol.116 , pp. 603-608
    • Suh, L.H.1    Dawson, D.G.2    Mutapcic, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.