메뉴 건너뛰기




Volumn 54, Issue 11-12, 2011, Pages 2999-3006

On arterial blood flow in the presence of an overlapping stenosis

Author keywords

Arterial flow; Blood flow; Impedance; Shear stress; Stenosis throats

Indexed keywords

ARTERIAL BLOOD; ARTERIAL FLOW; AXISYMMETRIC; BLOOD FLOW; BLOOD VISCOSITY; CRITICAL HEIGHT; FLUID VISCOSITY; RED CELLS; STENOSIS THROATS;

EID: 80052620720     PISSN: 08957177     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mcm.2011.07.028     Document Type: Article
Times cited : (43)

References (8)
  • 1
    • 77952989761 scopus 로고    scopus 로고
    • A mathematical model for the analysis of blood flow in arterial stenosis
    • Mishra B.K. A mathematical model for the analysis of blood flow in arterial stenosis. The Math. Edu. 2003, 37:176-181.
    • (2003) The Math. Edu. , vol.37 , pp. 176-181
    • Mishra, B.K.1
  • 2
    • 78449259508 scopus 로고    scopus 로고
    • Non-Newtonian model of blood flow through an arterial stenosis
    • Mishra B.K., Panda T.C. Non-Newtonian model of blood flow through an arterial stenosis. Acta Cienc. Indica 2005, 31(M2):341-348.
    • (2005) Acta Cienc. Indica , vol.31 , Issue.M2 , pp. 341-348
    • Mishra, B.K.1    Panda, T.C.2
  • 3
    • 0015650235 scopus 로고
    • Flow characteristics in model of arterial stenosis-steady flow
    • Young D.F., Tsai F.Y. Flow characteristics in model of arterial stenosis-steady flow. J. Biomech. 1973, 6:395-410.
    • (1973) J. Biomech. , vol.6 , pp. 395-410
    • Young, D.F.1    Tsai, F.Y.2
  • 4
    • 15944417062 scopus 로고    scopus 로고
    • Numerical solution of unsteady blood flow through an indented tube with atherosclerosis
    • Venkateswarlu K., Rao J.A. Numerical solution of unsteady blood flow through an indented tube with atherosclerosis. Indian J. Biochem. Biophys. 2004, 41:241-245.
    • (2004) Indian J. Biochem. Biophys. , vol.41 , pp. 241-245
    • Venkateswarlu, K.1    Rao, J.A.2
  • 5
    • 79952032242 scopus 로고    scopus 로고
    • Non-Newtonian arterial blood flow through an overlapping stenosis
    • Srivastava V.P., Rastogi R., Mishra S. Non-Newtonian arterial blood flow through an overlapping stenosis. Appl. Appl. Math.: Int. J. 2010, 5(1):225-238.
    • (2010) Appl. Appl. Math.: Int. J. , vol.5 , Issue.1 , pp. 225-238
    • Srivastava, V.P.1    Rastogi, R.2    Mishra, S.3
  • 6
    • 0002229165 scopus 로고
    • Mathematical modeling of blood flow through an overlapping stenosis
    • Chacravart S., Mandal P.K. Mathematical modeling of blood flow through an overlapping stenosis. Math. Comput. Model. 1994, 19:59-73.
    • (1994) Math. Comput. Model. , vol.19 , pp. 59-73
    • Chacravart, S.1    Mandal, P.K.2
  • 8
    • 85008547434 scopus 로고
    • Effects of a time-dependent stenosis of flow through a tube
    • Young D.F. Effects of a time-dependent stenosis of flow through a tube. J. Eng. Ind. 1968, 90:248-254.
    • (1968) J. Eng. Ind. , vol.90 , pp. 248-254
    • Young, D.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.