메뉴 건너뛰기




Volumn 57, Issue 5, 2011, Pages 395-398

In vivo evaluation of a new surfactant polymer coating mimicking the glycocalyx of endothelial cells

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD PUMP; BLOOD SAMPLES; CARDIOPULMONARY BYPASS; CPB CIRCUITS; GAS EXCHANGE; HEPARINIZATION; IN-VIVO; OUTLET PRESSURES; OXYGEN TRANSFER RATE; POLYMER COATING; PUMP PERFORMANCE;

EID: 80052491722     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e318229ac9c     Document Type: Article
Times cited : (4)

References (8)
  • 1
    • 60849083283 scopus 로고    scopus 로고
    • Advances in mechanical circulatory support
    • Louis LB 4th, Sun B: Advances in mechanical circulatory support. Curr Opin Organ Transplant 13: 522-525, 2008.
    • (2008) Curr Opin Organ Transplant , vol.13 , pp. 522-525
    • Louis IV, L.B.1    Sun, B.2
  • 2
    • 0035007741 scopus 로고    scopus 로고
    • Efficacy of a new coating material, PMEA, for cardiopulmonary bypass circuits in a porcine model
    • Suhara H, Sawa Y, Nishimura M, et al: Efficacy of a new coating material, PMEA, for cardiopulmonary bypass circuits in a porcine model. Ann Thorac Surg 71: 1603-1608, 2001.
    • (2001) Ann Thorac Surg , vol.71 , pp. 1603-1608
    • Suhara, H.1    Sawa, Y.2    Nishimura, M.3
  • 4
    • 0032560218 scopus 로고    scopus 로고
    • Biomimetic engineering of non-adhesive glycocalyx-like surfaces using oligosaccharide surfactant polymers
    • DOI 10.1038/33894
    • Holland NB, Qiu Y, Ruegsegger M, Marchant RE: Biomimetic engineering of non-adhesive glycocalyx-like surfaces using oligosaccharide surfactant polymers. Nature 392: 799-801, 1998. (Pubitemid 28225316)
    • (1998) Nature , vol.392 , Issue.6678 , pp. 799-801
    • Holland, N.B.1    Qiu, Y.2    Ruegsegger, M.3    Marchant, R.E.4
  • 5
    • 77149159780 scopus 로고    scopus 로고
    • Use of zirconia ceramic in the DexAide right ventricular assist device journal bearing
    • Saeed D, Horvath DJ, Massiello AL, et al: Use of zirconia ceramic in the DexAide right ventricular assist device journal bearing. Artif Organs 34: 146-149, 2010.
    • (2010) Artif Organs , vol.34 , pp. 146-149
    • Saeed, D.1    Horvath, D.J.2    Massiello, A.L.3
  • 6
    • 32644459146 scopus 로고    scopus 로고
    • Glycocalyx-mimetic dextran-modified poly(vinyl amine) surfactant coating reduces platelet adhesion on medical-grade polycarbonate surface
    • DOI 10.1016/j.biomaterials.2006.01.002, PII S0142961206000111
    • Gupta AS, Wang S, Link E, et al: Glycocalyx-mimetic dextranmodified poly(vinyl amine) surfactant coating reduces platelet adhesion on medical-grade polycarbonate surface. Biomaterials 27: 3084-3095, 2006. (Pubitemid 43247582)
    • (2006) Biomaterials , vol.27 , Issue.16 , pp. 3084-3095
    • Sen Gupta, A.1    Wang, S.2    Link, E.3    Anderson, E.H.4    Hofmann, C.5    Lewandowski, J.6    Kottke-Marchant, K.7    Marchant, R.E.8
  • 7
    • 62949185781 scopus 로고    scopus 로고
    • Age and outcome after continuous-flow left ventricular assist device implantation as bridge to transplantation
    • Sandner SE, Zimpfer D, Zrunek P, et al: Age and outcome after continuous-flow left ventricular assist device implantation as bridge to transplantation. J Heart Lung Transplant 28: 367-372, 2009.
    • (2009) J Heart Lung Transplant , vol.28 , pp. 367-372
    • Sandner, S.E.1    Zimpfer, D.2    Zrunek, P.3
  • 8
    • 73349129701 scopus 로고    scopus 로고
    • HeartMate II Investigators: Advanced heart failure treated with continuous-flow left ventricular assist device
    • Slaughter MS, Rogers JG, Milano CA, et al; HeartMate II Investigators: Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 361: 2241-2251, 2009.
    • (2009) N Engl J Med , vol.361 , pp. 2241-2251
    • Slaughter, M.S.1    Rogers, J.G.2    Milano, C.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.