2
-
-
0033742666
-
IEE Proc. Sci. Meas. Technol.
-
10.1049/ip-smt:20000259, 1350-2344
-
Emsley, A.M., Xiao, X., Heywood, R.J., and Ali, M.: 'Degradation of cellulosic insulation in power transformers - part 2: formation of furan products in insulating oil', IEE Proc. Sci. Meas. Technol., 2000, 147, p. 110-11410.1049/ip-smt:20000259 1350-2344
-
(2000)
Degradation of cellulosic insulation in power transformers - part 2: formation of furan products in insulating oil
, vol.147
, pp. 110-114
-
-
Emsley, A.M.1
Xiao, X.2
Heywood, R.J.3
Ali, M.4
-
3
-
-
0141939650
-
Proc. Seventh Int. Conf. Properties and Applications of Dielectric Materials
-
June
-
Stebbins, R.D., Myers, D.S., and Shkolnik, A.B.: 'Furanic compounds in dielectric liquid samples: review and update of diagnostic interpretation and estimation of insulation ageing', Proc. Seventh Int. Conf. Properties and Applications of Dielectric Materials, June 2003, 3, p. 921-926
-
(2003)
Furanic compounds in dielectric liquid samples: review and update of diagnostic interpretation and estimation of insulation ageing
, vol.3
, pp. 921-926
-
-
Stebbins, R.D.1
Myers, D.S.2
Shkolnik, A.B.3
-
4
-
-
17644395307
-
IEEE Electr. Insul. Mag.
-
10.1109/MEI.2005.1412215, 0883-7554
-
Kachler, A.J., and Hohlein, I.: 'Aging of cellulose at transformer service temperatures - part 1: influence of type of oil and air on the degree of polymerization of pressboard, dissolved gases, and furanic compounds in oil', IEEE Electr. Insul. Mag., 2005, 21, p. 15-2110.1109/MEI.2005.1412215 0883-7554
-
(2005)
Aging of cellulose at transformer service temperatures - part 1: influence of type of oil and air on the degree of polymerization of pressboard, dissolved gases, and furanic compounds in oil
, vol.21
, pp. 15-21
-
-
Kachler, A.J.1
Hohlein, I.2
-
5
-
-
80052436709
-
-
'Remnant life estimation model using fuzzy logic for power transformer asset management', 2005, PhD, Curtin University of Technology
-
Arshad, M.: 'Remnant life estimation model using fuzzy logic for power transformer asset management', 2005, PhD, Curtin University of Technology
-
-
-
Arshad, M.1
-
6
-
-
0035193576
-
Proc. 2001 IEEE Seventh Int. Conf. on Solid Dielectrics
-
Shang, Y., Yang, L., Guo, Z.J., and Yan, Z.: 'Assessing aging of large transformers by furfural investigation', Proc. 2001 IEEE Seventh Int. Conf. on Solid Dielectrics, 2001, p. 272-274
-
(2001)
Assessing aging of large transformers by furfural investigation
, pp. 272-274
-
-
Shang, Y.1
Yang, L.2
Guo, Z.J.3
Yan, Z.4
-
8
-
-
80052470560
-
Int. Conf. on Advances in Power System Control, Operation and Management
-
MacAlpine, J.M.K., and Zhang, C.H.: 'Observations from measurements of the furfural content of oil samples from transmission transformers', Int. Conf. on Advances in Power System Control, Operation and Management, 2000, 2, p. 317-321
-
(2000)
Observations from measurements of the furfural content of oil samples from transmission transformers
, vol.2
, pp. 317-321
-
-
MacAlpine, J.M.K.1
Zhang, C.H.2
-
9
-
-
80052507269
-
-
ASTM: 'Standard test method for furanic compounds in electrical insulating liquids by high-performance liquid chromatography (HPLC)', D5837-05, 2005
-
ASTM: 'Standard test method for furanic compounds in electrical insulating liquids by high-performance liquid chromatography (HPLC)', D5837-05, 2005
-
-
-
-
10
-
-
80052426534
-
-
ITC: 'Unused hydrocarbon-based insulating liquids-test methods for evaluating the oxidation stability', IEC61125, 1992
-
ITC: 'Unused hydrocarbon-based insulating liquids-test methods for evaluating the oxidation stability', IEC61125, 1992
-
-
-
-
11
-
-
80052503708
-
-
http://www.gmu.edu/depts/SRIF/tutorial/gcd/gc-ms2.htm
-
-
-
-
12
-
-
0036880503
-
IEEE Electr. Insul. Mag.
-
10.1109/MEI.2002.1161455, 0883-7554
-
Wang, M., Vandermaar, A.J., and Srivastava, K.D.: 'Review of condition assessment of power transformers in service', IEEE Electr. Insul. Mag., 2002, 18, p. 12-2510.1109/MEI.2002.1161455 0883-7554
-
(2002)
Review of condition assessment of power transformers in service
, vol.18
, pp. 12-25
-
-
Wang, M.1
Vandermaar, A.J.2
Srivastava, K.D.3
-
13
-
-
0033691909
-
IEEE Int. Symp. on Electrical Insulation
-
Palmer, J.A., Xianghui, W., Shoureshi, R.A., Mander, A., Torgerson, D., and Rich, C.: 'Effect of aging on the spectral response of transformer oil', IEEE Int. Symp. on Electrical Insulation, 2000, p. 460-464
-
(2000)
Effect of aging on the spectral response of transformer oil
, pp. 460-464
-
-
Palmer, J.A.1
Xianghui, W.2
Shoureshi, R.A.3
Mander, A.4
Torgerson, D.5
Rich, C.6
-
14
-
-
80052478562
-
-
ASTM: 'Standard practice for describing and measuring performance of ultraviolet, visible, and near-infrared spectrophotometers', ASTM E275-01, 03.06), 2001 72-81
-
ASTM: 'Standard practice for describing and measuring performance of ultraviolet, visible, and near-infrared spectrophotometers', ASTM E275-01, (03.06), 2001, pp. 72-81
-
-
-
-
15
-
-
28444438913
-
Proc. 2005 Int. Conf. Machine Learning and Cybernetics
-
Chuan-Sheng, W., Li, H., and Li-Shan, K.: 'The automatic modeling of complex functions based on gene expression programming', Proc. 2005 Int. Conf. Machine Learning and Cybernetics, 2005, 5, p. 2870-2873
-
(2005)
The automatic modeling of complex functions based on gene expression programming
, vol.5
, pp. 2870-2873
-
-
Chuan-Sheng, W.1
Li, H.2
Li-Shan, K.3
-
16
-
-
38049044883
-
Third Int. Conf. on Natural Computation
-
Zhaohui, G., Gaobin, L., Zhenkun, Y., and Min, J.: 'Automatic modeling of complex functions with clonal selection-based gene expression programming', Third Int. Conf. on Natural Computation, 2007, p. 228-232
-
(2007)
Automatic modeling of complex functions with clonal selection-based gene expression programming
, pp. 228-232
-
-
Zhaohui, G.1
Gaobin, L.2
Zhenkun, Y.3
Min, J.4
-
19
-
-
0003771286
-
-
International Series in Intelligent Technologies, Kluwer Academic Publisher )
-
Li, H., and Gupta, M.M.: 'Fuzzy logic and intelligent systems', (International Series in Intelligent Technologies, Kluwer Academic Publisher 1995)
-
(1995)
Fuzzy logic and intelligent systems
-
-
Li, H.1
Gupta, M.M.2
|