메뉴 건너뛰기




Volumn 106, Issue 9, 2011, Pages 1705-1710

Influence of on-site cytopathology evaluation on the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic masses

Author keywords

[No Author keywords available]

Indexed keywords

ACUTE PANCREATITIS; ADULT; AGED; ARTICLE; ASPIRATION BIOPSY; BLEEDING; CLINICAL EVALUATION; CONTROLLED STUDY; CYSTADENOCARCINOMA; CYSTADENOMA; CYTOPATHOLOGY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; DIFFERENTIAL DIAGNOSIS; ENDOSCOPIC ECHOGRAPHY; FEMALE; GOLD STANDARD; HISTOPATHOLOGY; HUMAN; LYMPHOMA; MAJOR CLINICAL STUDY; MALE; METASTASIS; NEUROENDOCRINE TUMOR; PANCREAS ADENOCARCINOMA; PANCREAS BIOPSY; PANCREAS TUMOR; PATHOLOGIST; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; SQUAMOUS CELL CARCINOMA; TERATOMA; TUMOR LOCALIZATION;

EID: 80052463427     PISSN: 00029270     EISSN: 15720241     Source Type: Journal    
DOI: 10.1038/ajg.2011.119     Document Type: Article
Times cited : (302)

References (41)
  • 1
    • 0035409058 scopus 로고    scopus 로고
    • Pancreatic cancer: Current concepts in imaging for diagnosis and staging
    • Tamm E, Charnsangavej C. Pancreatic cancer: current concepts in imaging for diagnosis and staging. Cancer J 2001; 7: 298-311.
    • (2001) Cancer J , vol.7 , pp. 298-311
    • Tamm, E.1    Charnsangavej, C.2
  • 2
    • 77957353072 scopus 로고    scopus 로고
    • Quantitative endoscopic ultrasound elastography: An accurate method for the differentiation of solid pancreatic masses
    • Iglesias-Garcia J, Larino-Noia J, Abdulkader I et al. Quantitative endoscopic ultrasound elastography: an accurate method for the differentiation of solid pancreatic masses. Gastroenterology 2010; 139: 1172-80.
    • (2010) Gastroenterology , vol.139 , pp. 1172-1180
    • Iglesias-Garcia, J.1    Larino-Noia, J.2    Abdulkader, I.3
  • 4
    • 0030841344 scopus 로고    scopus 로고
    • Endoscopic ultrasonography
    • DOI 10.1002/bjs.1800841002
    • Rösch T. Endoscopic ultrasonography. Br J Surg 1997; 84: 1329-31. (Pubitemid 27443429)
    • (1997) British Journal of Surgery , vol.84 , Issue.10 , pp. 1329-1331
    • Rosch, T.1
  • 8
    • 0027986754 scopus 로고
    • Endoscopic ultrasound-guided fi neneedle aspiration
    • Chang KJ, Katz KD, Durbin TE et al. Endoscopic ultrasound-guided fi neneedle aspiration. Gastrointest Endosc 1994; 40: 694-9.
    • (1994) Gastrointest Endosc , vol.40 , pp. 694-699
    • Chang, K.J.1    Katz, K.D.2    Durbin, T.E.3
  • 9
    • 0033980883 scopus 로고    scopus 로고
    • Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies
    • Erickson RA, Sayage-Rabie L, Beisner RS. Factors ' predicting the number of EUS-guided fi ne-needle passes for diagnosis of pancreatic malignancies. Gastrointest Endosc 2000; 51: 184-90. (Pubitemid 30094512)
    • (2000) Gastrointestinal Endoscopy , vol.51 , Issue.2 , pp. 184-190
    • Erickson, R.A.1    Sayage-Rabie, L.2    Beissner R.Stephen3
  • 10
  • 12
    • 0036088045 scopus 로고    scopus 로고
    • Endosonography-guided fine needle aspiration biopsy in the evaluation of pancreatic masses
    • DOI 10.1016/S0002-9270(02)04133-3, PII S0002927002041333
    • Harewood GC, Wiersema MJ. Endosonography-guided fine needle aspiration biopsy in the evaluation of pancreatic masses. Am J Gastroenterol 2002; 97: 1386-91. (Pubitemid 34664782)
    • (2002) American Journal of Gastroenterology , vol.97 , Issue.6 , pp. 1386-1391
    • Harewood, G.C.1    Wiersema, M.J.2
  • 13
    • 0028946682 scopus 로고
    • Fine-needle aspiration cytology guided by endoscopic ultrasonography: Results in 141 patients
    • Giovannini M, Seitz JF, Monges F et al. Fine-needle aspiration cytology guided by endoscopic ultrasonography: results in 141 patients. Endoscopy 1995; 27: 171-7.
    • (1995) Endoscopy , vol.27 , pp. 171-177
    • Giovannini, M.1    Seitz, J.F.2    Monges, F.3
  • 14
    • 0030794899 scopus 로고    scopus 로고
    • Endoscopic ultrasound-guided fine-needle aspiration biopsy using linear array and radial scanning endosonography
    • DOI 10.1016/S0016-5107(97)70266-9
    • Gress FG, Hawes RH, Savides TJ et al. Endoscopic ultrasound-guided fineneedle aspiration biopsy using linear array and radial scanning endosonography . Gastrointest Endosc 1997; 45: 243-50. (Pubitemid 27423804)
    • (1997) Gastrointestinal Endoscopy , vol.45 , Issue.3 , pp. 243-250
    • Gress, F.G.1    Hawes, R.H.2    Savides, T.J.3    Ikenberry, S.O.4    Lehman, G.A.5
  • 15
    • 0037263729 scopus 로고    scopus 로고
    • Diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration in patients with presumed pancreatic cancer
    • Raut CP, Grau AM, Staerkel GA et al. Diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration in patients with presumed pancreatic cancer. J Gastrointest Surg 2003; 7: 118-26.
    • (2003) J Gastrointest Surg , vol.7 , pp. 118-126
    • Raut, C.P.1    Grau, A.M.2    Staerkel, G.A.3
  • 16
    • 0030914312 scopus 로고    scopus 로고
    • Endosonography-guided fine-needle aspiration biopsy: Diagnostic accuracy and complication assessment
    • Wiersema MJ, Vilmann P, Giovannini nnini M e t al. Endosonography-guided fine-needle aspiration biopsy: diagnostic accuracy and complication assessment . Gastroenterology 1997; 112: 1087-95. (Pubitemid 27157518)
    • (1997) Gastroenterology , vol.112 , Issue.4 , pp. 1087-1095
    • Wiersema, M.J.1    Vilmann, P.2    Giovannini, M.3    Chang, K.J.4    Wiersema, L.M.5
  • 21
    • 3242743595 scopus 로고    scopus 로고
    • EUS-guided FNA
    • DOI 10.1016/S0016-5107(04)01529-9, PII S0016510704015299
    • Erickson RA. EUS-guided FNA. Gastrointest Endosc 2004; 60: 267-79. (Pubitemid 38980687)
    • (2004) Gastrointestinal Endoscopy , vol.60 , Issue.2 , pp. 267-279
    • Erickson, R.A.1
  • 23
    • 0038310881 scopus 로고    scopus 로고
    • Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration
    • DOI 10.1111/j.1572-0241.2003.07472.x
    • Klapman JB, Logro ñ o R, Dye CE et al. Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration . Am J Gastroenterol 2003; 98: 1289-94. (Pubitemid 36741524)
    • (2003) American Journal of Gastroenterology , vol.98 , Issue.6 , pp. 1289-1294
    • Klapman, J.B.1    Logrono, R.2    Dye, C.E.3    Waxman, I.4
  • 25
    • 0030831942 scopus 로고    scopus 로고
    • The clinical utility of endoscopic ultrasound-guided fine-needle aspiration in the diagnosis and staging of pancreatic carcinoma
    • Chang KJ, Nguyen P, Ericsson RA et al. The clinical utility of endoscopic ultrasound-guided fine needle aspiration in the diagnosis and staging of pancreatic carcinoma. Gastrointest Endosc 1997; 45: 387-93. (Pubitemid 27426180)
    • (1997) Gastrointestinal Endoscopy , vol.45 , Issue.5 , pp. 387-393
    • Chang, K.J.1    Nguyen, P.2    Erickson, R.A.3    Durbin, T.E.4    Katz, K.D.5
  • 26
    • 30344482593 scopus 로고    scopus 로고
    • Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB): Past, present, and future
    • DOI 10.1007/s00535-005-1717-6
    • Yamao K, Sawaki A, Mizuno N et al. Endoscopic ultrasound fine-needle aspiration biopsy (EUS-FNAB): past, present, and future. J Gastroenterol 2005; 40: 1013-23. (Pubitemid 43055284)
    • (2005) Journal of Gastroenterology , vol.40 , Issue.11 , pp. 1013-1023
    • Yamao, K.1    Sawaki, A.2    Mizuno, N.3    Shimizu, Y.4    Yatabe, Y.5    Koshikawa, T.6
  • 27
    • 0035487131 scopus 로고    scopus 로고
    • Interactive role of the cytopathologist in EUS-guided fine needle aspiration: An efficient approach
    • DOI 10.1067/mge.2001.118445
    • Logrono R, Waxman I. Interactive role of the cytopathologist in EUSguided fine needle aspiration: an effective approach. Gastrointest Endosc 2001; 54: 485-90. (Pubitemid 33661155)
    • (2001) Gastrointestinal Endoscopy , vol.54 , Issue.4 , pp. 485-490
    • Logrono, R.1    Waxman, I.2
  • 28
    • 65049091460 scopus 로고    scopus 로고
    • Endoscopic ultrasound-guided fine needle aspiration of solid pancreatic masses with rapid on-site cytological evaluation by endosonographers without attendance of cytopathologist
    • Hikichi T, Irisawa A, Buthani MS et al. Endoscopic ultrasound-guided fine needle aspiration of solid pancreatic masses with rapid on-site cytological evaluation by endosonographers without attendance of cytopathologist. J Gastroenterol 2009; 44: 322-8.
    • (2009) J Gastroenterol , vol.44 , pp. 322-328
    • Hikichi, T.1    Irisawa, A.2    Buthani, M.S.3
  • 29
    • 60849118386 scopus 로고    scopus 로고
    • Does onsite cytotechnology evaluation improve the accuracy of endoscopic ultrasound-guided fine needle aspiration biopsy?
    • Alsohaibani F, Girgis S, Sandha GS. Does onsite cytotechnology evaluation improve the accuracy of endoscopic ultrasound-guided fine needle aspiration biopsy? Can J Gastroenterol 2009; 23: 26-30.
    • (2009) Can J Gastroenterol , vol.23 , pp. 26-30
    • Alsohaibani, F.1    Girgis, S.2    Sandha, G.S.3
  • 30
    • 0028878286 scopus 로고
    • Fine needle aspiration of the pancreas in quest of accuracy
    • Robins DB, Katz RL, Evans DB et al. Fine needle aspiration of the pancreas. In quest of accuracy. Acta Cytol 1995; 39: 1-10.
    • (1995) Acta Cytol , vol.39 , pp. 1-10
    • Robins, D.B.1    Katz, R.L.2    Evans, D.B.3
  • 31
    • 0030766978 scopus 로고    scopus 로고
    • Guidelines of the Papanicolau Society of Cytopathology for fine needle aspiration procedure and reporting: The Papanicolau Society of Cytology Task Force on Standards of Practice
    • Suen KC, Abdul-Karim FW, Kaminsky DB et al. Guidelines of the Papanicolau Society of Cytopathology for fine needle aspiration procedure and reporting: the Papanicolau Society of Cytology Task Force on Standards of Practice. Diagn Cytopathol 1997; 17: 239-47.
    • (1997) Diagn Cytopathol , vol.17 , pp. 239-247
    • Suen, K.C.1    Abdul-Karim, F.W.2    Kaminsky, D.B.3
  • 32
    • 0024494419 scopus 로고
    • Sources of diagnostic error in fine needle aspiration of the thyroid
    • DOI 10.1002/1097-0142(19890215)63:4<718::AID-CNCR2820630420>3.0. CO;2-N
    • Hall TL, Layfi eld LJ, Philippe A et al. Sources of diagnostic error in fine needle aspiration of the thyroid. Cancer 1989; 63: 718-25. (Pubitemid 19050276)
    • (1989) Cancer , vol.63 , Issue.4 , pp. 718-725
    • Hall, T.L.1    Layfield, L.J.2    Philippe, A.3    Rosenthal, D.L.4
  • 33
    • 0027397342 scopus 로고
    • Value of having a cytopathologist present during percutaneous fine-needle aspiration biopsy of lung: Report of 55 cancer patients and metaanalysis of the literature
    • Austin JH, Cohen MB. Value of having a cytopathologist present during percutaneous fine needle aspiration biopsy of lung: report of 55 cancer patients and meta-analysis of the literature. AJR Am J Roentgenol 1993; 160: 175-7. (Pubitemid 23029953)
    • (1993) American Journal of Roentgenology , vol.160 , Issue.1 , pp. 175-177
    • Austin, J.H.M.1    Cohen, M.B.2
  • 34
    • 0022517114 scopus 로고
    • Fine needle aspiration biopsy: The role of immediate cytologic assessment
    • Miller DA, Carrasco CH, Katz RL et al. Fine needle aspiration biopsy: role of immediate cytological assessment. AJR Am Roentgenol 1986; 147: 155-8. (Pubitemid 16066344)
    • (1986) American Journal of Roentgenology , vol.147 , Issue.1 , pp. 155-158
    • Miller, D.A.1    Carrasco, C.H.2    Katz, R.L.3
  • 35
    • 0023881603 scopus 로고
    • Fine needle aspiration of breast masses: A critical review of 1956 cases in 8 years (1977-1984)
    • Palombini L, Fulciniti F, Vertani A et al. Fine needle aspiration of breast masses: a critical review of 1956 cases in 8 years (1977-1984). Cancer 1988; 61: 2273-7.
    • (1988) Cancer , vol.61 , pp. 2273-2277
    • Palombini, L.1    Fulciniti, F.2    Vertani, A.3
  • 36
    • 0033961651 scopus 로고    scopus 로고
    • Diagnostic value of lymph node fine needle aspiration cytology: An institutional experience of 387 cases observed over a 5-year period
    • DOI 10.1046/j.1365-2303.2000.00208.x
    • Nasuti JF, Yu G, Boudousquie A et al. Diagnostic value of lymph node fine needle aspiration cytology: an institutional experience of 387 cases observed over a 5 year period. Cytopathology 2000; 11: 18-31. (Pubitemid 30106434)
    • (2000) Cytopathology , vol.11 , Issue.1 , pp. 18-31
    • Nasuti, J.F.1    Yu, G.2    Boudousquie, A.3    Gupta, P.4
  • 38
    • 33845434138 scopus 로고    scopus 로고
    • Agreement between rapid onsite and final cytologic interpretations of EUS-guided FNA specimens: Implications for the endosonographer and patient management
    • DOI 10.1111/j.1572-0241.2006.00852.x
    • Eloubeidi MA, Tamhane A, Jhala N et al. Agreement between rapid onsite and final cytologic interpretations of EUS-guided FNA specimens: implications for the endosonographer and patient management. Am J Gastroenterol 2006; 101: 2841-7. (Pubitemid 44902659)
    • (2006) American Journal of Gastroenterology , vol.101 , Issue.12 , pp. 2841-2847
    • Eloubeidi, M.A.1    Tamhane, A.2    Jhala, N.3    Chhieng, D.4    Jhala, D.5    Crowe, D.R.6    Eltoum, I.A.7
  • 41
    • 33645242835 scopus 로고    scopus 로고
    • Frequency of major complications aft er EUS-guided FNA of solid pancreatic masses: A prospective evaluation
    • Eloubeidi MA, Tamhane A, Varadarajulu S et al. Frequency of major complications aft er EUS-guided FNA of solid pancreatic masses: a prospective evaluation. Gastrointest Endosc 2006; 63: 622-9.
    • (2006) Gastrointest Endosc , vol.63 , pp. 622-629
    • Eloubeidi, M.A.1    Tamhane, A.2    Varadarajulu, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.