메뉴 건너뛰기




Volumn 6, Issue 4, 2011, Pages 356-363

Communication and control system for a 15-channel hermetic retinal prosthesis

Author keywords

Biomedical electrodes; Integrated circuit design; Iridium oxide; Medical devices; Neuromuscular stimulation; Retinal implant; Retinal prosthesis; Telemetry

Indexed keywords

ELECTRODES; IMPLANTS (SURGICAL); INTEGRATED CIRCUIT DESIGN; INTEGRATED CIRCUIT MANUFACTURE; OPHTHALMOLOGY; POWER AMPLIFIERS; PROSTHETICS; SODIUM CHLORIDE; TELEMETERING;

EID: 80052458963     PISSN: 17468094     EISSN: 17468108     Source Type: Journal    
DOI: 10.1016/j.bspc.2011.05.007     Document Type: Article
Times cited : (4)

References (22)
  • 4
    • 0345445897 scopus 로고    scopus 로고
    • Perceptual efficacy of electrical stimulation of human retina with a microelectrode array during short-term surgical trials
    • J.F. Rizzo III, J. Wyatt, J. Loewenstein, S. Kelly, and D. Shire Perceptual efficacy of electrical stimulation of human retina with a microelectrode array during short-term surgical trials Invest. Ophthalmol. Vis. Sci. 44 2003 5362 5369
    • (2003) Invest. Ophthalmol. Vis. Sci. , vol.44 , pp. 5362-5369
    • Rizzo Iii, J.F.1    Wyatt, J.2    Loewenstein, J.3    Kelly, S.4    Shire, D.5
  • 5
    • 0345014794 scopus 로고    scopus 로고
    • Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode arrays
    • J.F. Rizzo III, J. Wyatt, J. Loewenstein, S. Kelly, and D. Shire Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode arrays Invest. Ophthalmol. Vis. Sci. 44 2003 5355 5361
    • (2003) Invest. Ophthalmol. Vis. Sci. , vol.44 , pp. 5355-5361
    • Rizzo Iii, J.F.1    Wyatt, J.2    Loewenstein, J.3    Kelly, S.4    Shire, D.5
  • 7
    • 33847669848 scopus 로고    scopus 로고
    • Experimental implantation of epiretinal retina implants (EPI-RET) with an IOL-type receiver unit
    • H. Gerding, F.P. Benner, and S. Taneri Experimental implantation of epiretinal retina implants (EPI-RET) with an IOL-type receiver unit J. Neural Eng. vol. 4 2007 S38 S49
    • (2007) J. Neural Eng. , vol.4 VOL.
    • Gerding, H.1    Benner, F.P.2    Taneri, S.3
  • 9
    • 31044443749 scopus 로고    scopus 로고
    • Implantation and testing of subretinal film electrodes in domestic pigs
    • T. Schanze, H.G. Sachs, C. Wiesenack, U. Brunner, and H. Sailer Implantation and testing of subretinal film electrodes in domestic pigs Exp. Eye Res. 82 2006 332 340
    • (2006) Exp. Eye Res. , vol.82 , pp. 332-340
    • Schanze, T.1    Sachs, H.G.2    Wiesenack, C.3    Brunner, U.4    Sailer, H.5
  • 10
    • 41149178026 scopus 로고    scopus 로고
    • A suprachoroidal electrical retinal stimulator design for long-term animal experiments and in-vivo assessment of its feasibility and biocompatibility in rabbits
    • J.A. Zhou, S.J. Woo, S.I. Park, E.T. Kim, J.M. Seo, H. Chung, and S.J. Kim A suprachoroidal electrical retinal stimulator design for long-term animal experiments and in-vivo assessment of its feasibility and biocompatibility in rabbits J. Biomed. Biotechnol. 2008 547428-1 547428-10
    • (2008) J. Biomed. Biotechnol. , pp. 5474281-54742810
    • Zhou, J.A.1    Woo, S.J.2    Park, S.I.3    Kim, E.T.4    Seo, J.M.5    Chung, H.6    Kim, S.J.7
  • 14
    • 65549142134 scopus 로고    scopus 로고
    • Restoring neuroretinal function: New potentials
    • E. Zrenner Restoring neuroretinal function: new potentials Doc. Ophthalmol. 115 2007 56 59
    • (2007) Doc. Ophthalmol. , vol.115 , pp. 56-59
    • Zrenner, E.1
  • 17
    • 33847649689 scopus 로고    scopus 로고
    • Responses of ganglion cells to repetitive electrical stimulation of the retina
    • R.J. Jensen, and J.F. Rizzo III Responses of ganglion cells to repetitive electrical stimulation of the retina J. Neural Eng. 4 2007 S1 S6
    • (2007) J. Neural Eng. , vol.4
    • Jensen, R.J.1    Rizzo Iii, J.F.2
  • 19
    • 54049125391 scopus 로고    scopus 로고
    • A low-power fully implantable 15-channel retinal stimulator chip
    • L.S. Theogarajan A low-power fully implantable 15-channel retinal stimulator chip IEEE J. Solid-State Circ. 43 2008 2322 2337
    • (2008) IEEE J. Solid-State Circ. , vol.43 , pp. 2322-2337
    • Theogarajan, L.S.1
  • 20
    • 67649884471 scopus 로고    scopus 로고
    • Extraction of a chronically-implanted, microfabricated, subretinal electrode array
    • J. Chen, H.A. Shah, C. Herbert, J.I. Loewenstein, and J.F. Rizzo Extraction of a chronically-implanted, microfabricated, subretinal electrode array Ophthalmic Res. Vol. 43 No. 3 2009 128 137
    • (2009) Ophthalmic Res. , vol.43 , Issue.3 , pp. 128-137
    • Chen, J.1    Shah, H.A.2    Herbert, C.3    Loewenstein, J.I.4    Rizzo, J.F.5
  • 22
    • 33744937327 scopus 로고    scopus 로고
    • In vivo electrical stimulation of rabbit retina: Effect of stimulus duration and electric field orientation
    • H.A. Shah, S.R. Montezuma, and J.F. Rizzo III In vivo electrical stimulation of rabbit retina: effect of stimulus duration and electric field orientation Exp. Eye Res. 83 2 2006 247 254
    • (2006) Exp. Eye Res. , vol.83 , Issue.2 , pp. 247-254
    • Shah, H.A.1    Montezuma, S.R.2    Rizzo Iii, J.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.