메뉴 건너뛰기




Volumn 38, Issue PART 5, 2010, Pages 316-321

Quantifying the distortion of distance observations caused by scattering in time-of-flight range cameras

Author keywords

Internal reflection; Photonic mixer device; Range camera; Range imaging; Scattering; Systematic error

Indexed keywords

FACE RECOGNITION; PIXELS; SCATTERING; SENSORS; SYSTEMATIC ERRORS; AMPLITUDE MODULATION; ERRORS; LENSES; MIXERS (MACHINERY); PHASE SHIFT; PHOTONIC DEVICES;

EID: 80052456110     PISSN: 16821750     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (14)

References (11)
  • 3
    • 63549105205 scopus 로고    scopus 로고
    • Range camera calibration based on image sequences and dense comprehensive error statistics
    • San José, USA, proc. SPIE Vol. 7239
    • Karel, W., Pfeifer, N., 2009. Range camera calibration based on image sequences and dense comprehensive error statistics. In: Three Dimensional Imaging Metrology, San José, USA, proc. SPIE Vol. 7239-12.
    • (2009) Three Dimensional Imaging Metrology , pp. 12
    • Karel, W.1    Pfeifer, N.2
  • 5
    • 85088254269 scopus 로고    scopus 로고
    • Time-of-flight range imaging with a custom solid state image sensor
    • proc. SPIE Vol. 3823
    • Lange, R., Seitz, P., Biber, A., Schwarte, R., 1999. Time-of-flight range imaging with a custom solid state image sensor. In: Laser Metrology and Inspection, proc. SPIE Vol. 3823, pp. 180-191.
    • (1999) Laser Metrology and Inspection , pp. 180-191
    • Lange, R.1    Seitz, P.2    Biber, A.3    Schwarte, R.4
  • 7
    • 63549144198 scopus 로고    scopus 로고
    • Surface-dependent 3d range camera self-calibration
    • San José, USA, proc. SPIE Vol. 7239
    • Lichti, D., Rouzaud, D., 2009. Surface-dependent 3D range camera self-calibration. In: Three Dimensional Imaging Metrology, San José, USA, proc. SPIE Vol. 7239.
    • (2009) Three Dimensional Imaging Metrology
    • Lichti, D.1    Rouzaud, D.2
  • 8
    • 42449138396 scopus 로고    scopus 로고
    • Calibration of the intensity-related distance error of the pmd tof-camera
    • proc. SPIE Vol. 6764/
    • Lindner, M., Kolb, A., 2007: Calibration of the intensity-related distance error of the PMD TOF-camera. In: Intelligent Robots and Computer Vision XXV, proc. SPIE Vol. 6764/1.
    • (2007) Intelligent Robots and Computer Vision , vol.25 , pp. 1
    • Lindner, M.1    Kolb, A.2
  • 11
    • 84862695319 scopus 로고    scopus 로고
    • Dissertation at the Institute of Photogrammetry and Remote Sensing, Vienna University of Technology, Austria
    • Otepka, J., 2004: Precision target mensuration in vision metrology. Dissertation at the Institute of Photogrammetry and Remote Sensing, Vienna University of Technology, Austria.
    • (2004) Precision Target Mensuration in Vision Metrology
    • Otepka, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.