메뉴 건너뛰기




Volumn 38, Issue 9, 2011, Pages 2063-2067

The OMERACT ultrasound task force - Status and perspectives

(27)  Naredo, Esperanza a   Wakefield, Richard J b   Iagnocco, Annamaria c   Terslev, Lene d   Filippucci, Emilio e   Gandjbakhch, Frederique f   Aegerter, Philippe g   Aydin, Sibel h   Backhaus, Marina i   Balint, Peter V j   Bruyn, George A W k   Collado, Paz a   Finzel, Stephanie l   Freeston, Jane E h   Gutierrez, Marwin e   Joshua, Frederick m   Jousse Joulin, Sandrine n   Kane, David o   Keen, Helen I p   Moller, Ingrid q   more..


Author keywords

Enthesitis; Omeract; Power doppler; Standardization; Synovitis; Ultrasound

Indexed keywords

CLINICAL ASSESSMENT; CONFERENCE PAPER; DELPHI DEFINITION EXERCISE; ENTHESITIS; HAND OSTEOARTHRITIS; HUMAN; INTEROBSERVER RELIABILITY; INTRAOBSERVER RELIABILITY; JOINT EXAMINATION; OMERACT ULTRASOUND GLOBAL SYNOVITIS SCORE; OSTEOARTHRITIS; PRIORITY JOURNAL; RELIABILITY; RHEUMATOID ARTHRITIS; SCORING SYSTEM; SPONDYLOSIS; SYNOVITIS; ULTRASOUND;

EID: 80052341629     PISSN: 0315162X     EISSN: 14992752     Source Type: Journal    
DOI: 10.3899/jrheum.110425     Document Type: Conference Paper
Times cited : (105)

References (24)
  • 2
    • 17244380959 scopus 로고    scopus 로고
    • Impact of ultrasound imaging on local corticosteroid injections of symptomatic ankle, hind-, and mid-foot in chronic inflammatory diseases
    • DOI 10.1002/art.21078
    • D'Agostino M.A., Ayral X., Baron G., Ravaud P., Breban M., Dougados M. Impact of ultrasound imaging on local corticosteroid injections of symptomatic ankle, hind- and mid-foot in chronic inflammatory diseases. Arthritis Rheum 2005;53:284-292 (Pubitemid 40530171)
    • (2005) Arthritis Care and Research , vol.53 , Issue.2 , pp. 284-292
    • D'Agostino, M.-A.1    Ayral, X.2    Baron, G.3    Ravaud, P.4    Breban, M.5    Dougados, M.6
  • 8
    • 33751272241 scopus 로고    scopus 로고
    • Intra- and inter-observer reliability of ultrasonography for detecting and scoring synovitis in rheumatoid arthritis: A report of a EULAR ESCISIT Task Force
    • abstract
    • D'Agostino M.A., Wakefield R., Filippucci E., Backhaus M., Balint P.V., Bouffard J.A., et al. Intra- and inter-observer reliability of ultrasonography for detecting and scoring synovitis in rheumatoid arthritis: A report of a EULAR ESCISIT Task Force [abstract]. Ann Rheum Dis 2005;64:62.
    • (2005) Ann Rheum Dis , vol.64 , pp. 62
    • D'Agostino, M.A.1    Wakefield, R.2    Filippucci, E.3    Backhaus, M.4    Balint, P.V.5    Bouffard, J.A.6
  • 9
    • 68849097051 scopus 로고    scopus 로고
    • The OMERACT ultrasound task force - Advances and priorities
    • Erratum in: J Rheumatol 2009;36:2625
    • D'Agostino M.A., Conaghan P.G., Naredo E., Aegerter P., Iagnocco A., Freeston J.E., et al. The OMERACT ultrasound task force - Advances and priorities. J Rheumatol 2009;36:1829-1832Erratum in: J Rheumatol 2009;36:2625.
    • (2009) J Rheumatol , vol.36 , pp. 1829-1832
    • D'Agostino, M.A.1    Conaghan, P.G.2    Naredo, E.3    Aegerter, P.4    Iagnocco, A.5    Freeston, J.E.6
  • 10
    • 68849093143 scopus 로고    scopus 로고
    • Combined evaluation of influence of sonographer and machine type on the reliability of power Doppler ultrasonography (PDUS) for detecting, scoring and scanning synovitis in rheumatoid arthritis (RA) patients: Results of an intermachine reliability exercise of the EULAR/OMERACT US group
    • abstract
    • Wakefield R., D'Agostino M.A., Backhaus M., Balint P.V., Bruyn G.A.W., Filippucci E., et al. Combined evaluation of influence of sonographer and machine type on the reliability of power Doppler ultrasonography (PDUS) for detecting, scoring and scanning synovitis in rheumatoid arthritis (RA) patients: Results of an intermachine reliability exercise of the EULAR/OMERACT US group [abstract]. Ann Rheum Dis 2008;67:421.
    • (2008) Ann Rheum Dis , vol.67 , pp. 421
    • Wakefield, R.1    D'Agostino, M.A.2    Backhaus, M.3    Balint, P.V.4    Bruyn, G.A.W.5    Filippucci, E.6
  • 11
    • 68849127502 scopus 로고    scopus 로고
    • Evaluation of the intra- and inter-reader reliability of power Doppler ultrasonography (PDUS) for detecting and scoring synovitis of several joints in rheumatoid arthritis (RA) by using a validated scoring system: A report of the EULAR/OMERACT US group
    • abstract
    • D'Agostino M.A., Wakefield R., Backhaus M., Balint P.V., Bruyn G.A.W., Filippucci E., et al. Evaluation of the intra- and inter-reader reliability of power Doppler ultrasonography (PDUS) for detecting and scoring synovitis of several joints in rheumatoid arthritis (RA) by using a validated scoring system: A report of the EULAR/OMERACT US group [abstract]. Ann Rheum Dis 2008;67:422.
    • (2008) Ann Rheum Dis , vol.67 , pp. 422
    • D'Agostino, M.A.1    Wakefield, R.2    Backhaus, M.3    Balint, P.V.4    Bruyn, G.A.W.5    Filippucci, E.6
  • 12
    • 61449185555 scopus 로고    scopus 로고
    • Reliability of ultrasonography in detecting shoulder disease in patients with rheumatoid arthritis
    • Bruyn G.A., Naredo E., Moller I., Moragues C., Garrido J., De Bock G.H., et al. Reliability of ultrasonography in detecting shoulder disease in patients with rheumatoid arthritis. Ann Rheum Dis 2009;68:357-361
    • (2009) Ann Rheum Dis , vol.68 , pp. 357-361
    • Bruyn, G.A.1    Naredo, E.2    Moller, I.3    Moragues, C.4    Garrido, J.5    De Bock, G.H.6
  • 13
    • 77955294261 scopus 로고    scopus 로고
    • Validity of ultrasonography and measures of adult shoulder function and reliability of ultrasonography in detecting shoulder synovitis in patients with rheumatoid arthritis using MRI as a gold standard
    • Bruyn G.A., Pineda C., Diaz C.H., Ventura-Rios L., Moya C., Garrido J., et al. Validity of ultrasonography and measures of adult shoulder function and reliability of ultrasonography in detecting shoulder synovitis in patients with rheumatoid arthritis using MRI as a gold standard. Arthritis Care Res 2010;62:1079-1086
    • (2010) Arthritis Care Res , vol.62 , pp. 1079-1086
    • Bruyn, G.A.1    Pineda, C.2    Diaz, C.H.3    Ventura-Rios, L.4    Moya, C.5    Garrido, J.6
  • 14
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis J.R., Koch G.G. The measurement of observer agreement for categorical data. Biometrics 1977;33:159-174 (Pubitemid 8054849)
    • (1977) Biometrics , vol.33 , Issue.1 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 15
    • 80052322728 scopus 로고    scopus 로고
    • A systematic literature review analysis of ultrasound joint count and scoring systems to assess synovitis in rheumatoid arthritis according to the OMERACT filter
    • Mandl P., Naredo E., Wakefield R.J., Conaghan P.G., D'Agostino M.A. A systematic literature review analysis of ultrasound joint count and scoring systems to assess synovitis in rheumatoid arthritis according to the OMERACT filter. J Rheumatol 2011;38:2055-2062
    • (2011) J Rheumatol , vol.38 , pp. 2055-2062
    • Mandl, P.1    Naredo, E.2    Wakefield, R.J.3    Conaghan, P.G.4    D'Agostino, M.A.5
  • 17
    • 69749098912 scopus 로고    scopus 로고
    • Evaluation of a novel 7-joint ultrasound score in daily rheumatologic practice: A pilot project
    • Backhaus M., Ohrndorf S., Kellner H., Strunk J., Backhaus T.M., Hartung W., et al. Evaluation of a novel 7-joint ultrasound score in daily rheumatologic practice: A pilot project. Arthritis Rheum 2009;61:1194-1201
    • (2009) Arthritis Rheum , vol.61 , pp. 1194-1201
    • Backhaus, M.1    Ohrndorf, S.2    Kellner, H.3    Strunk, J.4    Backhaus, T.M.5    Hartung, W.6
  • 18
    • 0036786842 scopus 로고    scopus 로고
    • Ultrasonography of entheseal insertions in the lower limb in spondyloarthropathy
    • Balint P.V., Kane D., Wilson H., McInnes I.B., Sturrock R.D. Ultrasonography of entheseal insertions in the lower limb in spondyloarthropathy. Ann Rheum Dis 2002;61:905-910
    • (2002) Ann Rheum Dis , vol.61 , pp. 905-910
    • Balint, P.V.1    Kane, D.2    Wilson, H.3    McInnes, I.B.4    Sturrock, R.D.5
  • 19
    • 0037331654 scopus 로고    scopus 로고
    • Assessment of peripheral enthesitis in the spondylarthropathies by ultrasonography combined with power Doppler: A cross-sectional study
    • DOI 10.1002/art.10812
    • D'Agostino M.A., Said-Nahal R., Hacquard-Bouder C., Brasseur J.L., Dougados M., Breban M. Assessment of peripheral enthesitis in the spondylarthropathies by ultrasonography combined with power Doppler. Arthritis Rheum 2003;48:523-533 (Pubitemid 36278022)
    • (2003) Arthritis and Rheumatism , vol.48 , Issue.2 , pp. 523-533
    • D'Agostino, M.-A.1    Said-Nahal, R.2    Hacquard-Bouder, C.3    Brasseur, J.-L.4    Dougados, M.5    Breban, M.6
  • 22
    • 58349090052 scopus 로고    scopus 로고
    • How to evaluate and improve the reliability of power Doppler ultrasonography for assessing enthesitis in spondylarthritis
    • D'Agostino M.A., Aegerter P., Jousse-Joulin S., Chary-Valckenaere I., Lecoq B., Gaudin P., et al. How to evaluate and improve the reliability of power Doppler ultrasonography for assessing enthesitis in spondylarthritis. Arthritis Rheum 2009;61:61-69
    • (2009) Arthritis Rheum , vol.61 , pp. 61-69
    • D'Agostino, M..A.1    Aegerter, P.2    Jousse-Joulin, S.3    Chary-Valckenaere, I.4    Lecoq, B.5    Gaudin, P.6
  • 23
    • 70350170660 scopus 로고    scopus 로고
    • Reliability of high-resolution ultrasonography in the assessment of Achilles tendon enthesopathy in seronegative spondyloarthropathies
    • Filippucci E., Aydin S.Z., Karadag O., Salaffi F., Gutierrez M., Direskeneli H., et al. Reliability of high-resolution ultrasonography in the assessment of Achilles tendon enthesopathy in seronegative spondyloarthropathies. Ann Rheum Dis 2009;68:1850-1855
    • (2009) Ann Rheum Dis , vol.68 , pp. 1850-1855
    • Filippucci, E.1    Aydin, S.Z.2    Karadag, O.3    Salaffi, F.4    Gutierrez, M.5    Direskeneli, H.6
  • 24
    • 66149102108 scopus 로고    scopus 로고
    • A systematic review of ultrasonography in osteoarthritis
    • Keen H.I., Wakefield R.J., Conaghan P.G. A systematic review of ultrasonography in osteoarthritis. Ann Rheum Dis 2009;68:611-619
    • (2009) Ann Rheum Dis , vol.68 , pp. 611-619
    • Keen, H.I.1    Wakefield, R.J.2    Conaghan, P.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.