메뉴 건너뛰기




Volumn , Issue , 2011, Pages

Two-dimensional noncontact vital sign detection using Doppler radar array approach

Author keywords

Doppler radar; non contact; radar array; random body movement; spectrum analysis; vital sign detection

Indexed keywords

ACQUISITION MODULES; BASEBAND ANALOGS; BODY MOVEMENTS; DC OFFSETS; DC-OFFSET COMPENSATION; DETECTING SENSITIVITY; DETECTION PERFORMANCE; HUMAN BODIES; HUMAN BODY MOVEMENT; HUMAN SUBJECTS; NON-CONTACT; POWER MANAGEMENT CIRCUITS; RADAR ARRAY; RADAR ARRAYS; RADIO FREQUENCY TRANSCEIVER; RANDOM WALK; VITAL SIGN;

EID: 80052338844     PISSN: 0149645X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MWSYM.2011.5972723     Document Type: Conference Paper
Times cited : (29)

References (7)
  • 1
    • 0027022165 scopus 로고
    • Microwave sensing of physiological movement and volume change: A review
    • J. C. Lin, "Microwave sensing of physiological movement and volume change: A review", Bioelectromagnetics, vol. 13, pp. 557-565, 1992.
    • (1992) Bioelectromagnetics , vol.13 , pp. 557-565
    • Lin, J.C.1
  • 2
    • 0033962823 scopus 로고    scopus 로고
    • Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier
    • DOI 10.1109/10.817625, PII S0018929400002421
    • K. M. Chen, Y. Huang, J. Zhang, and A. Norman, "Microwave life-detection systems for searching human subjects under earthquake rubble and behind barrier", IEEE Trans. Biomed. Eng., vol. 47, pp. 105-114, Jan. 2000. (Pubitemid 30044006)
    • (2000) IEEE Transactions on Biomedical Engineering , vol.47 , Issue.1 , pp. 105-114
    • Chen, K.-M.1    Huang, Y.2    Zhang, J.3    Norman, A.4
  • 3
    • 1842527440 scopus 로고    scopus 로고
    • Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring"
    • March
    • A. D. Droitcour, O. Boric-Lubecke, V. M. Lubecke, J. Lin, and G. T. A. Kovac, "Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring", IEEE Trans. Microwave Theory and Techniques, vol. 52, pp. 838-848, March 2004.
    • (2004) IEEE Trans. Microwave Theory and Techniques , vol.52 , pp. 838-848
    • Droitcour, A.D.1    Boric-Lubecke, O.2    Lubecke, V.M.3    Lin, J.4    Kovac, G.T.A.5
  • 4
    • 57349171370 scopus 로고    scopus 로고
    • Complex Signal Demodulation and Random Body Movement Cancellation Techniques for Non-contact Vital Sign Detection
    • June
    • C. Li, and J. Lin, "Complex Signal Demodulation and Random Body Movement Cancellation Techniques for Non-contact Vital Sign Detection," IEEE MTT-S International Microwave Symposium Digest, pp. 567-570, June, 2008.
    • (2008) IEEE MTT-S International Microwave Symposium Digest , pp. 567-570
    • Li, C.1    Lin, J.2
  • 5
    • 70350599528 scopus 로고    scopus 로고
    • Signal-to-noise ratio in Doppler radar system for heart and respiratory measurement
    • October
    • A. D. Droitcour, O. Boric-Lubecke, and G. T. A. Kovacs, "signal-to-noise ratio in Doppler radar system for heart and respiratory measurement", IEEE Trans. Microwave Theory and Techniques, vol. 57, pp. 2498-2507, October, 2009.
    • (2009) IEEE Trans. Microwave Theory and Techniques , vol.57 , pp. 2498-2507
    • Droitcour, A.D.1    Boric-Lubecke, O.2    Kovacs, G.T.A.3
  • 7
    • 33847755555 scopus 로고    scopus 로고
    • Experiment and Spectral Analysis of a Low-Power Ka-Band Heartbeat Detector Measuring from Four Sides of a Human Body
    • IMS 2006 Special Issue, December
    • C. Li, Y. Xiao, and J. Lin, "Experiment and Spectral Analysis of a Low-Power Ka-Band Heartbeat Detector Measuring from Four Sides of a Human Body", IEEE Trans. Microwave Theory and Techniques, IMS 2006 Special Issue, vol. 54, no. 12, pp. 4464-4470, December 2006.
    • (2006) IEEE Trans. Microwave Theory and Techniques , vol.54 , Issue.12 , pp. 4464-4470
    • Li, C.1    Xiao, Y.2    Lin, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.