메뉴 건너뛰기




Volumn 33, Issue 2, 2011, Pages 176-182

Application of adaptive control in a refrigeration system to improve performance

Author keywords

Adaptive; Coefficient of performance; Control; Fuzzy; Refrigeration system

Indexed keywords

ADAPTIVE; ADAPTIVE CONTROL; ADAPTIVE FUZZY CONTROL; COEFFICIENT OF PERFORMANCE; ELECTRONIC CARDS; EXPERIMENTAL INVESTIGATIONS; FREQUENCY INVERTER; FUZZY; LABVIEW SOFTWARE; PIEZORESISTIVE PRESSURE TRANSDUCERS; REFRIGERATION SYSTEM; SERIAL PORT; SIGNAL OUTPUT; THERMOSTATIC EXPANSION VALVES; VARIABLE SPEED COMPRESSORS;

EID: 80052333296     PISSN: 16785878     EISSN: 18063691     Source Type: Journal    
DOI: 10.1590/S1678-58782011000200008     Document Type: Article
Times cited : (10)

References (14)
  • 2
    • 33644584032 scopus 로고    scopus 로고
    • Experimental analysis of the scroll compressor performances varying its speed
    • Aprea, C., Mastrullo, R., Renno, C., 2006, "Experimental analysis of the scroll compressor performances varying its speed". Applied Thermal Engineering, Vol. 26, Issue 10, pp. 983-992.
    • (2006) Applied Thermal Engineering , vol.26 , Issue.10 , pp. 983-992
    • Aprea, C.1    Mastrullo, R.2    Renno, C.3
  • 4
    • 80052315013 scopus 로고    scopus 로고
    • M.Sc. Thesis - Faculty of Mechanical Engineering, Federal University of Uberlândia, MG, Brasil (In Portuguese)
    • Carvajal, F., 2000, "Digital control of expansion valves using Fuzzy Logic", M.Sc. Thesis - Faculty of Mechanical Engineering, Federal University of Uberlândia, MG, Brasil, 74 p. (In Portuguese)
    • (2000) Digital Control of Expansion Valves Using Fuzzy Logic , pp. 74
    • Carvajal, F.1
  • 8
    • 0035400590 scopus 로고    scopus 로고
    • Advanced fuzzy logic controllers design and evaluation for buildings' occupants thermal-visual comfort and indoor air quality satisfaction
    • DOI 10.1016/S0378-7788(00)00098-0, PII S0378778800000980
    • Kolokotsa, D., Tsiavos, D., Stavrakakis, G.S, Kalaitzakis, K., Antonidakis, E., "Advanced fuzzy logic controllers design and evaluation for buildings occupants thermal-visual comfort and indoor air quality satisfaction", Energy and Buildings, Vol. 33, No. 6, pp. 531-543, 2001. (Pubitemid 32446635)
    • (2001) Energy and Buildings , vol.33 , Issue.6 , pp. 531-543
    • Kolokotsa, D.1    Tsiavos, D.2    Stavrakakis, G.S.3    Kalaitzakis, K.4    Antonidakis, E.5
  • 9
    • 0035283358 scopus 로고    scopus 로고
    • Numerical simulation of a variable speed refrigeration system
    • DOI 10.1016/S0140-7007(00)00014-1
    • Koury, R.N., Machado, L.E, Ismail, K.A.R. 2001, "Numerical simulation of variable speed refrigeration", Int. J. Refrigeration, Vol. 24, Issue 2, pp. 192-200. (Pubitemid 32139230)
    • (2001) International Journal of Refrigeration , vol.24 , Issue.2 , pp. 192-200
    • Koury, R.N.N.1    MacHado, L.2    Ismail, K.A.R.3
  • 10
    • 0020241953 scopus 로고
    • Development of energy saving oriented variable capacity system heat pump
    • Lida, K., Yamamoto, T., Kuroda, T., Hibi, H., 1982, "Development of energy saving oriented variable capacity system heat pump", ASHRAE Trans, Vol. 88, pp. 441-449.
    • (1982) ASHRAE Trans , vol.88 , pp. 441-449
    • Lida, K.1    Yamamoto, T.2    Kuroda, T.3    Hibi, H.4
  • 11
    • 0020239374 scopus 로고
    • Trends of residential air-conditioning cyclic tests
    • Nguyen, H., Goldschmidt, V., Thomas, S., Tree, D., 1982, "Trends of residential air-conditioning cyclic tests", ASHRAE Transactions, Vol. 88, No. 2, pp. 954-972. (Pubitemid 14500447)
    • (1982) ASHRAE Transactions , vol.88 , Issue.PART 2 , pp. 954-972
    • Nguyen Han, V.1    Goldschmidt, V.W.2    Thomas, S.B.3    Tree, D.R.4
  • 12
    • 0001622716 scopus 로고
    • Performance degradation during ON/OFF cycling of single-speed heat pumps operating in the cooling mode: Experimental results
    • O'neal, D.L. and Katipamula, S., 1991, "Performance Degradation During ON/OFF Cycling of Single-Speed Heat Pumps Operating in the Cooling Mode: Experimental Results", ASHRAE Transactions, Vol. 97, No. 2, pp. 316-323.
    • (1991) ASHRAE Transactions , vol.97 , Issue.2 , pp. 316-323
    • O'neal, D.L.1    Katipamula, S.2
  • 13
    • 10044282514 scopus 로고    scopus 로고
    • Performance representation of variable-speed compressor for inverter air conditioners based on experimental data
    • Shunagquan, S., 2004, "Performance representation of variable-speed compressor for inverter air conditioners based on experimental data", Int. J. Refrigeration, Vol. 27, Issue 8, pp. 805- 815.
    • (2004) Int. J. Refrigeration , vol.27 , Issue.8 , pp. 805-815
    • Shunagquan, S.1
  • 14
    • 0029306170 scopus 로고
    • Simulation in transient regime of a heat pump with closed-loop and on-off control
    • Vargas, J.V.C. and Parise, J.A.R., 1995, "Simulation in transient regime of a heat pump with closed-loop and on-off control", Int. J. Refrigeration, Vol. 18, No. 4, pp. 235-243.
    • (1995) Int. J. Refrigeration , vol.18 , Issue.4 , pp. 235-243
    • Vargas, J.V.C.1    Parise, J.A.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.